Donate Help Contact The AHA Sign In Home
American Heart Association
Circulation
Search: search_blue_button Advanced Search
Circulation. 2003;107:2660-2663
Published online before print May 27, 2003, doi: 10.1161/01.CIR.0000074778.46065.24
This Article
Right arrow Abstract Freely available
Right arrow Full Text (PDF)
Right arrow All Versions of this Article:
107/21/2660    most recent
01.CIR.0000074778.46065.24v1
Right arrow Alert me when this article is cited
Right arrow Alert me if a correction is posted
Right arrow Citation Map
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Download to citation manager
Right arrow Request Permissions
Citing Articles
Right arrow Citing Articles via HighWire
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Mintz, G. S.
Right arrow Articles by Weissman, N. J.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Mintz, G. S.
Right arrow Articles by Weissman, N. J.
Related Collections
Right arrow Catheter-based coronary interventions: stents
Right arrow Coronary imaging: angiography/ultrasound/Doppler/CC

(Circulation. 2003;107:2660.)
© 2003 American Heart Association, Inc.


Brief Rapid Communications

Regional Remodeling as the Cause of Late Stent Malapposition

Gary S. Mintz, MD; Vivek M. Shah, MS; Neil J. Weissman, MD

From the Cardiovascular Research Foundation (G.S.M.), New York, NY; and Cardiovascular Research Institute (V.MS, N.J.W.), Washington Hospital Center, Washington, DC.

Correspondence to Neil J. Weissman, MD, Washington Hospital Center, 110 Irving St, NW Suite 4B-1, Washington DC 20010. E-mail neil.j.weissman{at}medstar.net


*    Abstract
up arrowTop
*Abstract
down arrowIntroduction
down arrowMethods
down arrowResults
down arrowDiscussion
down arrowReferences
 
Background— Late stent malapposition (LSM) is only detected if intravascular ultrasound (IVUS) is performed at implantation and follow-up. We used a novel "regional" IVUS analysis to assess the mechanism of LSM.

Methods and Results— Corresponding image slices on postimplantation and follow-up IVUS studies of 11 malapposed stents were identified and electronically rotated until they were aligned. The geometric center of the stent was identified, and the angle of late malapposition measured. Radii were drawn from this center through the transition points between complete apposition and LSM. These two circumferences were divided into equal arcs, and radii were drawn to the external elastic membrane (EEM). Measurements included EEM radius and circumference, plaque and media (P&M=EEM minus stent radius) thickness and area, and stent-intima separation. Mean baseline EEM radius and P&M thickness were similar in apposed and malapposed circumferences. At follow-up, mean EEM radius increase within the malapposed circumference (0.57±0.34 mm) was larger than within the apposed circumference (0.16±0.18 mm; P=0.0004). {Delta}EEM for each malapposed radius was greater than for each apposed radius (P<0.05 for all comparisons). Stent-intima separation correlated with EEM radius increase within the malapposed circumference (r=0.83, P=0.0013). At follow-up, the mean P&M thickness decreased in the malapposed circumference (-0.31±0.22 mm; P<0.0001). However, the decrease in P&M thickness in the malapposed circumference occurred because the same P&M area was distributed over a larger circumference (4.1±1.6 mm to 5.4±3.0 mm; P=0.05), the result of positive remodeling.

Conclusion— The main cause of LSM is a regional increase in EEM (regional positive remodeling).


Key Words: stents • drugs • restenosis • imaging


*    Introduction
up arrowTop
up arrowAbstract
*Introduction
down arrowMethods
down arrowResults
down arrowDiscussion
down arrowReferences
 
Late stent malapposition (LSM) has been reported after brachytherapy, drug-eluting stents, and de novo bare-metal stent implantation.1–4 Postulated mechanisms include (1) malapposition not recognized at implantation and only detected at follow-up, (2) decrease in plaque, (3) chronic stent recoil, and (4) increase in arterial dimensions. However, LSM is typically focal. Therefore, analysis of total arterial and plaque dimensions may not be the ideal approach to understanding this focal process. Analysis of total external elastic membrane (EEM) and plaque cross-sectional area or volume may obscure regional changes in remodeling or plaque mass. We hypothesized that analysis of localized changes in EEM dimensions would identify remodeling behind the arc of late malapposition as the primary cause of LSM.


*    Methods
up arrowTop
up arrowAbstract
up arrowIntroduction
*Methods
down arrowResults
down arrowDiscussion
down arrowReferences
 
Patient Selection
From the Washington Hospital Center core intravascular ultrasound (IVUS) database, 11 stents (11 patients) with LSM were identified. All patients underwent de novo tubular-slotted stent placement (two were drug-eluting stents) into a native coronary (without adjunct brachytherapy) not in the setting of an acute myocardial infarction. LSM was defined as separation of >=1 stent strut from the intima, not overlapping a side-branch, with evidence of blood flow behind the strut, where postimplantation IVUS revealed no evidence of blood speckling behind any strut.

IVUS Imaging and Analysis
IVUS imaging was performed after intracoronary administration of 0.1 to 0.2 mg nitroglycerin using motorized transducer pullback and a commercially available scanner (SCIMED). The imaging catheter was advanced 10 mm distal to the stent, and the transducer was withdrawn at 0.5 mm/s back to the guiding catheter. All studies were recorded on 0.5-inch high-resolution s-VHS videotape for subsequent analysis.

Quantitative IVUS analysis was performed using computerized planimetry (Tape Measure, Indec Systems). The follow-up study was reviewed first to select the image slice with the largest LSM area. Then, the postintervention study was reviewed to identify the corresponding image slice; this was facilitated by motorized transducer pullback because the distance from the stent edge could be measured in both studies. Finally, postintervention and follow-up image slices were rotated electronically so that patterns of stent struts and perivessel landmarks were aligned.5,6

The LSM image slice was analyzed first. (1) The geometric stent center was identified, and the angle of LSM measured with an electronic protractor. (2) Radii were drawn from this center through the two transition points between circumferences of complete apposition and LSM. (3) These two circumferences were divided into equal arcs, and 8 additional radii were drawn to the EEM, three through the apposed arc and five through the malapposed arc (Figure 1). (4) Radial distances were measured from the stent center to the stent, intima, and EEM. (5) Plaque and media (P&M) thickness was calculated as EEM minus stent radius. (6) Separation of LSM was calculated as intimal minus stent radius. (7) The P&M areas and EEM circumferences in apposed and malapposed segments were measured. These same measurements were performed on postimplantation images.



View larger version (152K):
[in this window]
[in a new window]
 
Figure 1. This IVUS image slice in an area of LSM is divided into 10 radii: nos. 1 to 5 through the circumference of complete stent-vessel wall apposition and nos. 6 to 10 through the LSM circumference.

Statistics
Statistical analysis was performed using StatView 5.0 (SAS Institute). Quantitative data are presented as mean±1SD and compared using paired Student’s t test, correlation coefficient, and analysis of variance for repeated measures (with post hoc analysis using Fisher’s protected least significant difference).


*    Results
up arrowTop
up arrowAbstract
up arrowIntroduction
up arrowMethods
*Results
down arrowDiscussion
down arrowReferences
 
Stent-vessel wall malapposition was located almost exclusively at stent edges: 6 proximal edge, 4 distal edge, and 1 within the stent body. The angle of LSM averaged 89±39° (31° to 175°) or 25±11% (9% to 49%) of the stent circumference. The length averaged 3.7±2.8 mm.

Overall, there was a 0.37±0.24-mm increase in EEM radius (2.4±0.3 to 2.8±0.4 mm; P=0.0005), whereas there was no change in P&M thickness (0.8±0.2 to 0.7±0.2 mm; P=0.2). This represented a 15±15 (2% to 33%) increase in EEM radius.

The Table shows index and follow-up IVUS measurements according to the 10 predefined radii. Mean baseline EEM radius and P&M thickness were similar in apposed and malapposed circumferences. At follow-up, there was a consistent increase in EEM of all malapposed radii, but not of all fully apposed radii. The increase in mean EEM radius within the malapposed circumference (0.57±0.34 mm) was larger than within the apposed circumference (0.16±0.18 mm; P=0.0004). This increase averaged 6±8% (0% to 21%) within the apposed circumference versus 24±15% (2% to 56%) within the malapposed circumference. Stent-intima separation correlated with {Delta}EEM radius within the malapposed circumference (r=0.83, P=0.0013).


View this table:
[in this window]
[in a new window]
 
IVUS Measurements (in mm)

At follow-up, mean P&M thickness increased in the apposed circumference (0.18±0.16 mm) and decreased in the malapposed circumference (-0.31±0.22 mm; P<0.0001). However, there was no actual decrease in plaque mass behind the malapposed part of the stent; P&M area measured 1.9±0.9 mm2 at implantation and 2.3±1.4 mm2 at follow-up (P=0.4). The decrease in P&M thickness occurred because the same P&M was distributed over a larger circumference (4.1±1.6 mm to 5.4±3.0 mm; P=0.05), the result of positive remodeling. Stent-intima separation did not correlate with P&M thickness decrease (P=0.3). In the fully apposed circumference, there was an increase in P&M area from 7.2±2.6 mm2 to 9.8±2.9 mm2; P=0.0003).

Figure 2 shows the distance stent-intima separation (measure of LSM) and changes in EEM radius and P&M thickness for the 10 prespecified radii. {Delta}EEM radius and {Delta}P&M thickness were similar for all prespecified radii within the apposed circumference as well as within the malapposed circumference. However, {Delta}EEM for each malapposed radius was greater than for each apposed radius, and {Delta}P&M thickness for each malapposed radius was significantly different than for each apposed radius (P<0.05 for all comparisons).



View larger version (26K):
[in this window]
[in a new window]
 
Figure 2. Mean±1SD of (1) stent-intima separation, (2) {Delta}EEM radius, and (3) {Delta}P&M thickness are shown. Prespecified radii on the x-axis correspond to Figure 1. There were no statistically significant differences in {Delta}EEM radius or {Delta}P&M thickness comparing radii nos. 1 to 5 or among stent-intima separation, {Delta}EEM radius, or {Delta}P&M thickness comparing radii nos. 6 to 10. However, {Delta}EEM radius was larger and {Delta}P&M thickness smaller among radii nos. 6 to 10 compared with radii nos. 1 to 5. There was no actual decrease in plaque mass behind the malapposed part of the stent; P&M area measured 1.9±0.9 mm2 at implantation and 2.3±1.4 mm2 at follow-up (P=0.4). Rather, the same P&M area was distributed over a larger EEM circumference.


*    Discussion
up arrowTop
up arrowAbstract
up arrowIntroduction
up arrowMethods
up arrowResults
*Discussion
down arrowReferences
 
LSM occurs in 4% to 5% of bare-metal stents and in an, as yet, unknown percentage of drug eluting stents.3 LSM is a focal phenomenon occupying, in the present study, approximately 25% of the stent circumference. In RAVEL, malapposition averaged 154° in sirolimus-eluting stents (43% of the stent circumference) and 131° in placebo stents (36% of the stent circumference).2 Therefore, LSM is uncommon and focal; mechanistic studies of LSM require assessment of regional remodeling and changes in plaque thickness.

Mechanisms of Late Malapposition
In the present analysis, there was no decrease in any of the stent radii eliminating chronic stent recoil as a finding, but allowing the geometric center of the stent to be used as a constant point of reference. In the current analysis, there was an increase in EEM radius (positive remodeling) within the region of LSM, but no change in plaque mass; the separation of the intima from the stent correlated with the increase in EEM radius. Therefore, the main mechanism of LSM is regional positive remodeling occurring in the setting of no increase in plaque mass. These regional changes were not well detected when changes in total EEM radius were assessed. IVUS analysis of LSM, as well as other focal arterial phenomena, requires a methodology appropriate to the problem. It may not be appropriate to assess mechanisms of LSM (a focal phenomenon) by measuring changes in total arterial EEM or plaque CSA or volume—even if these are the "standard" analyses performed in IVUS laboratories. Standard analyses may obscure rather than elucidate the actual mechanism. Similar "regional" methodologies may be useful in understanding remodeling responses to focal, eccentric plaque accumulation in de novo lesion formation.

Using serial IVUS, a number of investigators have reported positive remodeling associated with peri-stent plaque increase after bare-metal stent implantation, presumably reflecting peri-stent intimal hyperplasia.7,8 The present analysis suggests that EEM increase is not necessarily a response to peri-stent intimal hyperplasia, but can occur independently. Positive remodeling without an increase in intimal hyperplasia has been noted after brachytherapy.4,9 The present analysis suggests that this phenomenon can occur in the absence of brachytherapy.

The decrease in P&M thickness (but not mass) behind the malapposed stent struts was secondary to positive remodeling. Thus, plaque "thinning" may occur in the absence of plaque regression. In the current study P&M thickness decreased by 0.31±0.22 mm, whereas P&M area increased from 1.9±0.9 mm2 at implantation to 2.3±1.4 mm2 at follow-up.

Limitations
The number of patients with late malapposition was small. The current findings only apply to tubular-slotted stents. The present findings do not apply to re-stenting of in-stent restenosis lesions. The range of increase in malapposed arc EEM area was wide and <10% in 2/11 patients. There were only 2 IVUS studies per patient; therefore, the time course of remodeling (early or late) cannot be determined.

Conclusions
The main cause of late stent malapposition is a regional increase in EEM (regional positive remodeling) that may not be detected during conventional analyses.

Received March 6, 2003; revision received April 7, 2003; accepted April 17, 2003.


*    References
up arrowTop
up arrowAbstract
up arrowIntroduction
up arrowMethods
up arrowResults
up arrowDiscussion
*References
 

  1. Kozuma K, Costa MA, Sabaté M, et al. Late stent malapposition occurring after intracoronary ß-irradiation detected by intravascular ultrasound. J Invas Cardiol. 1999; 11: 651–655.[Medline] [Order article via Infotrieve]
  2. Serruys PW, Degertekin M, Tanabe K, et al. Intravascular ultrasound findings in the multicenter, randomized, double-blind RAVEL (RAndomized study with the sirolimus-eluting VElocity balloon-expandable stent in the treatment of patients with de novo native coronary artery Lesions) trial. Circulation. 2002; 106: 798–803.[Abstract/Free Full Text]
  3. Shah VM, Mintz GS, Apple S, et al. Background incidence of late malapposition after bare-metal stent implantation. Circulation. 2002; 106: 1753–1755.[Abstract/Free Full Text]
  4. Mintz GS, Weissman NJ, Fitzgerald PJ. Intravascular ultrasound assessment of the mechanisms and results of brachytherapy. Circulation. 2001; 104: 1320–1325.[Free Full Text]
  5. Hoffmann R, Mintz GS, Dussaillant GR, et al. Patterns and mechanisms of in-stent restenosis: A serial intravascular ultrasound study. Circulation. 1996; 94: 1247–1254.[Abstract/Free Full Text]
  6. Shiran A, Weissman NJ, Leiboff B, et al. Effect of preintervention plaque burden on subsequent intimal hyperplasia in stented coronary artery lesions. Am J Cardiol. 2000; 86: 1318–1321.[CrossRef][Medline] [Order article via Infotrieve]
  7. Hoffmann R, Mintz GS, Popma JJ, et al. Chronic arterial responses to stent implantation: A serial intravascular ultrasound analysis of Palmaz-Schatz stents in native coronary arteries. J Am Coll Cardiol. 1996; 28: 1134–1139.[Abstract]
  8. Nakamura M, Yock PG, Bonneau HN, et al. Impact of peri-stent remodeling on restenosis: a volumetric intravascular ultrasound study. Circulation. 2001; 103: 2130–2132.[Abstract/Free Full Text]
  9. Kay IP, Sabate M, Costa MA, et al. Positive geometric vascular remodeling is seen after catheter-based radiation followed by conventional stent implantation but not after radioactive stent implantation. Circulation. 2000; 102: 1434–1439.[Abstract/Free Full Text]



This article has been cited by other articles:


Home page
HeartHome page
R Hoffmann, M-C Morice, J W Moses, P J Fitzgerald, L Mauri, G Breithardt, J Schofer, P W Serruys, H-P Stoll, and M B Leon
Impact of late incomplete stent apposition after sirolimus-eluting stent implantation on 4-year clinical events: intravascular ultrasound analysis from the multicentre, randomised, RAVEL, E-SIRIUS and SIRIUS trials
Heart, March 1, 2008; 94(3): 322 - 328.
[Abstract] [Full Text] [PDF]


Home page
J Am Coll CardiolHome page
B. L. van der Hoeven, S.-S. Liem, J. W. Jukema, N. Suraphakdee, H. Putter, J. Dijkstra, D. E. Atsma, M. Bootsma, K. Zeppenfeld, P. V. Oemrawsingh, et al.
Sirolimus-eluting stents versus bare-metal stents in patients with ST-segment elevation myocardial infarction: 9-month angiographic and intravascular ultrasound results and 12-month clinical outcome results from the MISSION! Intervention Study.
J. Am. Coll. Cardiol., February 12, 2008; 51(6): 618 - 626.
[Abstract] [Full Text] [PDF]


Home page
Eur Heart JHome page
N. J. Weissman, S. G. Ellis, E. Grube, K. D. Dawkins, J. D. Greenberg, T. Mann, L. A. Cannon, P. A. Cambier, S. Fernandez, G. S. Mintz, et al.
Effect of the polymer-based, paclitaxel-eluting TAXUS Express stent on vascular tissue responses: a volumetric intravascular ultrasound integrated analysis from the TAXUS IV, V, and VI trials
Eur. Heart J., July 1, 2007; 28(13): 1574 - 1582.
[Abstract] [Full Text] [PDF]


Home page
Eur Heart JHome page
D. A. Siqueira, A. A. Abizaid, J. d. R. Costa, F. Feres, L. A. Mattos, R. Staico, A. A. Abizaid, L. F. Tanajura, A. Chaves, M. Centemero, et al.
Late incomplete apposition after drug-eluting stent implantation: incidence and potential for adverse clinical outcomes
Eur. Heart J., June 1, 2007; 28(11): 1304 - 1309.
[Abstract] [Full Text] [PDF]


Home page
CirculationHome page
G. S. Mintz
What to Do About Late Incomplete Stent Apposition?
Circulation, May 8, 2007; 115(18): 2379 - 2381.
[Full Text] [PDF]


Home page
CirculationHome page
S. Cook, P. Wenaweser, M. Togni, M. Billinger, C. Morger, C. Seiler, R. Vogel, O. Hess, B. Meier, and S. Windecker
Incomplete Stent Apposition and Very Late Stent Thrombosis After Drug-Eluting Stent Implantation
Circulation, May 8, 2007; 115(18): 2426 - 2434.
[Abstract] [Full Text] [PDF]


Home page
Eur Heart JHome page
D. Matsumoto, J. Shite, T. Shinke, H. Otake, Y. Tanino, D. Ogasawara, T. Sawada, O. L. Paredes, K.-i. Hirata, and M. Yokoyama
Neointimal coverage of sirolimus-eluting stents at 6-month follow-up: evaluated by optical coherence tomography
Eur. Heart J., April 2, 2007; 28(8): 961 - 967.
[Abstract] [Full Text] [PDF]


Home page
CirculationHome page
E. Camenzind, P. G. Steg, and W. Wijns
A Cause for Concern
Circulation, March 20, 2007; 115(11): 1440 - 1455.
[Full Text] [PDF]


Home page
J Am Coll CardiolHome page
P. Jimenez-Quevedo, M. Sabate, D. J. Angiolillo, M. A. Costa, F. Alfonso, J. A. Gomez-Hospital, R. Hernandez-Antolin, C. Banuelos, J. Goicolea, F. Fernandez-Aviles, et al.
Vascular Effects of Sirolimus-Eluting Versus Bare-Metal Stents in Diabetic Patients: Three-Dimensional Ultrasound Results of the Diabetes and Sirolimus-Eluting Stent (DIABETES) Trial
J. Am. Coll. Cardiol., June 6, 2006; 47(11): 2172 - 2179.
[Abstract] [Full Text] [PDF]


Home page
CirculationHome page
M.-K. Hong, G. S. Mintz, C. W. Lee, D.-W. Park, K.-M. Park, B.-K. Lee, Y.-H. Kim, J.-M. Song, K.-H. Han, D.-H. Kang, et al.
Late Stent Malapposition After Drug-Eluting Stent Implantation: An Intravascular Ultrasound Analysis With Long-Term Follow-Up
Circulation, January 24, 2006; 113(3): 414 - 419.
[Abstract] [Full Text] [PDF]


Home page
CirculationHome page
J. Aoki, A. Colombo, D. Dudek, A. P. Banning, J. Drzewiecki, K. Zmudka, F. Schiele, M. E. Russell, J. Koglin, P. W. Serruys, et al.
Peristent Remodeling and Neointimal Suppression 2 Years After Polymer-Based, Paclitaxel-Eluting Stent Implantation: Insights From Serial Intravascular Ultrasound Analysis in the TAXUS II Study
Circulation, December 20, 2005; 112(25): 3876 - 3883.
[Abstract] [Full Text] [PDF]


Home page
J Am Coll CardiolHome page
J. Ako, Y. Morino, Y. Honda, A. Hassan, S. Sonoda, P. G. Yock, M. B. Leon, J. W. Moses, H. N. Bonneau, and P. J. Fitzgerald
Late Incomplete Stent Apposition After Sirolimus-Eluting Stent Implantation: A Serial Intravascular Ultrasound Analysis
J. Am. Coll. Cardiol., September 20, 2005; 46(6): 1002 - 1005.
[Abstract] [Full Text] [PDF]


Home page
J Am Coll CardiolHome page
N. J. Weissman, J. Koglin, D. A. Cox, J. Hermiller, C. O'Shaughnessy, J. T. Mann, M. Turco, R. Caputo, P. Bergin, J. Greenberg, et al.
Polymer-based paclitaxel-eluting stents reduce in-stent neointimal tissue proliferation: A serial volumetric intravascular ultrasound analysis from the TAXUS-IV trial
J. Am. Coll. Cardiol., April 19, 2005; 45(8): 1201 - 1205.
[Abstract] [Full Text] [PDF]


Home page
CirculationHome page
K. Tanabe, P. W. Serruys, M. Degertekin, E. Grube, G. Guagliumi, W. Urbaszek, J. Bonnier, J.-M. Lablanche, T. Siminiak, J. Nordrehaug, et al.
Incomplete Stent Apposition After Implantation of Paclitaxel-Eluting Stents or Bare Metal Stents: Insights From the Randomized TAXUS II Trial
Circulation, February 22, 2005; 111(7): 900 - 905.
[Abstract] [Full Text] [PDF]


Home page
CirculationHome page
M.-K. Hong, G. S. Mintz, C. W. Lee, Y.-H. Kim, S.-W. Lee, J.-M. Song, K.-H. Han, D.-H. Kang, J.-K. Song, J.-J. Kim, et al.
Incidence, Mechanism, Predictors, and Long-Term Prognosis of Late Stent Malapposition After Bare-Metal Stent Implantation
Circulation, February 24, 2004; 109(7): 881 - 886.
[Abstract] [Full Text] [PDF]


Home page
CirculationHome page
R. Virmani, G. Guagliumi, A. Farb, G. Musumeci, N. Grieco, T. Motta, L. Mihalcsik, M. Tespili, O. Valsecchi, and F. D. Kolodgie
Localized Hypersensitivity and Late Coronary Thrombosis Secondary to a Sirolimus-Eluting Stent: Should We Be Cautious?
Circulation, February 17, 2004; 109(6): 701 - 705.
[Abstract] [Full Text] [PDF]


Home page
CirculationHome page
M. Degertekin, P. W. Serruys, K. Tanabe, C. H. Lee, J. E. Sousa, A. Colombo, M.-C. Morice, J. M.R. Ligthart, and P. J. de Feyter
Long-Term Follow-Up of Incomplete Stent Apposition in Patients Who Received Sirolimus-Eluting Stent for De Novo Coronary Lesions: An Intravascular Ultrasound Analysis
Circulation, December 2, 2003; 108(22): 2747 - 2750.
[Abstract] [Full Text] [PDF]


This Article
Right arrow Abstract Freely available
Right arrow Full Text (PDF)
Right arrow All Versions of this Article:
107/21/2660    most recent
01.CIR.0000074778.46065.24v1
Right arrow Alert me when this article is cited
Right arrow Alert me if a correction is posted
Right arrow Citation Map
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Download to citation manager
Right arrow Request Permissions
Citing Articles
Right arrow Citing Articles via HighWire
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Mintz, G. S.
Right arrow Articles by Weissman, N. J.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Mintz, G. S.
Right arrow Articles by Weissman, N. J.
Related Collections
Right arrow Catheter-based coronary interventions: stents
Right arrow Coronary imaging: angiography/ultrasound/Doppler/CC