| |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
(Circulation. 2002;106:798.)
© 2002 American Heart Association, Inc.
Clinical Investigation and Reports |
From the Thoraxcentre, Rotterdam, the Netherlands (P.W.S., M.D., K.T., J.L., P.d.F.); Institute Dante Pazzanese de Cardiologia, Sao Paulo, Brazil (A.A., J.E.S.); Centro Cuore Columbus, Milan, Italy (A.C.), Ospediali Riuniti di Bergamo, Bergamo, Italy (G.G.); Onze Lieve Vrouwe Ziekenhuis, Aalst, Belgium (W.W.); Cardialysis bv, Rotterdam, the Netherlands (W.K.L.); and Institut Cardiovasculaire Paris Sud, Massy, France (M.-C.M.).
Correspondence to Prof Patrick W. Serruys, Thoraxcentre, BD 404, Dr Molewaterplein 40, 3015 GD (PO Box 1738, 3000 DR), Rotterdam, The Netherlands. E-mail serruys{at}card.azr.nl
| Abstract |
|---|
|
|
|---|
Methods and Results In the RAVEL trial, 238 patients with single de novo lesions were randomized to receive either an 18-mm sirolimus-eluting stent (Bx VELOCITY stent, Cordis) or an uncoated stent (Bx VELOCITY stent). In a subset of 95 patients (sirolimus-eluting stent=48, uncoated stent=47), motorized intravascular ultrasound pullback (0.5 mm/s) was performed at a 6-month follow-up. Stent volumes, total vessel volumes, and plaque-behind-stent volumes were comparable. However, the difference in neointimal hyperplasia (2±5 versus 37±28 mm3) and percent of volume obstruction (1±3% versus 29±20%) at 6 months between the 2 groups was highly significant (P<0.001), emphasizing the nearly complete abolition of the proliferative process inside the drug-eluting stent. Analysis of the proximal and distal edge volumes showed no significant difference between the 2 groups in external elastic membrane or lumen and plaque volume at the proximal and distal edges. There was also no evidence of intrastent thrombosis or persisting dissection at the stent edges. Although there was a higher incidence of incomplete stent apposition in the sirolimus group compared with the uncoated stent group (P<0.05), it was not associated with any adverse clinical events at 1 year.
Conclusions Sirolimus-eluting stents are effective in preventing neointimal hyperplasia without creating edge effect and without affecting the plaque burden behind the struts.
Key Words: stents restenosis ultrasonics drugs
| Introduction |
|---|
|
|
|---|
Pilot studies testing the safety, feasibility, and efficacy of the sirolimus-eluting stent have demonstrated a near complete abolition of neointimal hyperplasia.1,2 These pilot studies have been conducted on patients with Benestent type lesions in large vessels, and the stents were implanted under intravascular ultrasound (IVUS) guidance.
The RAVEL trial is a multicenter randomized study involving patients with more complex lesions in smaller vessels in whom IVUS guidance was not used during stent implantation.3 In a subset of the enrolled patients, quantitative 3-dimensional IVUS assessment was performed at follow-up. The goal of this investigation was to provide a more detailed morphological analysis of the local biological effects of the implantation of a sirolimus-eluting stent.
Sirolimus has potent antiproliferative and antimigratory effects.4 Intravascular brachytherapy also has antiproliferative and antimigratory effects but has been associated with certain side effects, including edge restenosis, 5,6 persisting dissection,7,8 increased plaque burden outside the struts of the stent with expansion of the external elastic membrane,8,9 late malapposition, 10 late thrombotic occlusion, 11 and "black holes." 12,13
On the basis of the previous experience with brachytherapy, we specifically looked for any evidence of these harmful effects in the patients enrolled in the RAVEL trial.
| Methods |
|---|
|
|
|---|
50%; an ostial target lesion; a calcified lesion that could not be successfully predilated; an angiographically visible thrombus within the target lesion; a left ventricular ejection fraction below 30%; or intolerance to aspirin, clopidogrel, or ticlopidine.
Study Procedures
After successful predilatation, patients were randomized 1:1 in a double-blind fashion to undergo the implantation of either an uncoated metal Bx VELOCITY Balloon-Expandable Stent or a sirolimus-eluting Bx VELOCITY Balloon-Expandable Stent (Cordis Corp, Johnson & Johnson). The sirolimus-eluting stents were indistinguishable from the uncoated metal stents to the naked eye. Postdilatation was performed as necessary to achieve a residual stenosis below 20% with a TIMI grade III flow. In case of dissection or of incomplete coverage of the lesion, additional study stents from the same randomization assignment were used as necessary.
Heparin was administered in intravenous boluses to maintain an activated clotting time >250 seconds for the duration of the procedure and was discontinued within 12 hours. Aspirin, at least 100 mg, was administered 12 hours before the procedure and continued indefinitely. A loading dose of 300 mg of clopidogrel was administered, preferably 48 hours before the procedure, followed by 75 mg once daily for 8 weeks. Alternatively, ticlopidine 250 mg twice daily was begun 1 day before the procedure and continued for 8 weeks.
Patient Follow-Up
At 30 days, 6 months, and 12 months, patients underwent evaluation of anginal status according to the Canadian Cardiovascular Society Classification of angina14 and the Braunwald Classification for unstable angina,15 as well as monitoring of major adverse cardiac events or additional revascularization of the index target lesion. A 12-lead ECG was performed at each visit; follow-up angiography and an IVUS investigation was performed at 180±30 days.
Quantitative Coronary Angiography
Coronary angiograms were obtained in multiple views after patients had received an intracoronary injection of nitrates. Quantitative analyses of all pre-, peri-, and postprocedural angiographic data were performed by an independent core laboratory (Cardialysis, Rotterdam, the Netherlands) and analyzed quantitatively by edge-detection techniques.16 These data have been reported previously.
Quantitative Intravascular Ultrasound
At a 6-month follow-up, stented vessel segments were examined with mechanical IVUS (CardioVascular Imaging System, CVIS) using automated pullback at 0.5 mm per second. A coronary segment beginning 5 mm distal to and extending 5 mm proximal to the stented segment was also examined. A computer-based contour detection program was used for automated 3D reconstruction of the stented segment from up to 200 cross-sectional images. Lumen, stent boundaries, and external elastic membrane were detected using a minimum cost algorithm.17,18 Total vessel volume (TVV), stent volume (SV), and lumen volume (LV) were calculated as V=
ni=1 Ai · H, where V is volume, A is total vessel, stent, or lumen area (as desired) in a given cross-sectional image, H is thickness of the coronary artery slice, and n is the number of slices. Lumen volume did not include the incomplete apposition spaces, and in absence of neointimal hyperplasia, lumen volume was delineated by the boundaries of the struts. Total plaque volume (TPV), plaque volume behind the stent (PBS), and neointimal hyperplasia (NIH) were calculated as TVV-LV, TVV-SV, and SV-LV, respectively. Percentage of obstruction volume was calculated as neointimal volume/stent volume x 100 at the 6-month follow-up. For the segments proximal and distal to the stent, the vessel volume was measured at each cross section as the area lying within the external elastic lamina.
|
Feasibility, reproducibility and inter- and intra-observer variability of this system have been validated in vitro and in vivo.17,18 The quantitative ultrasound analyses were performed by an independent core laboratory (Cardialysis BV, Rotterdam, the Netherlands).
Qualitative IVUS parameters assessed in the study included persisting edge tears and incomplete stent apposition. Edge tears were defined as disruption of plaque immediately adjacent to the stent ends, where the flap could be clearly differentiated from the underlying plaque. Incomplete stent apposition was defined as 1 or more struts clearly separated from vessel wall with evidence of blood speckles behind the strut,19,20 and because it was based on the consensus of 3 independent analysts, the determination was blind for the type of stent used. The measures of agreement by Kappa analysis between 3 observers were 0.87, 0.85 and 0.80, respectively (P=NS).
The number of loci exhibiting areas of incomplete stent apposition per stent was determined by cross-sectional IVUS images. The total length of these single or multiple areas of incomplete apposition were calculated from the number of frames involved. The maximal number of struts separated from the vessel wall on 1 single cross section, as well as the maximal depth (distance between the most incompletely apposed strut and the vessel wall) and the maximal circumferential extent of incomplete apposition (expressed in angular degrees) are reported. Finally, the volume of the incompletely apposed segments was quantified in mm3 and related to the stent volume-in percent (Figure 1).
End Points
The primary end point of the study is angiographic in-stent late loss at a 6-month follow-up as determined by quantitative coronary angiography. The secondary clinical end point of the study was a composite of major adverse cardiac events, including cardiac and noncardiac death, Q-wave and nonQ-wave myocardial infarctions, coronary artery bypass grafts, or target lesion or vessel revascularizations at 30 days, 6 months, and 12 months after the index procedure.3
Statistical Analysis
All analyses were performed on an intention-to-treat basis. Treatment group differences were tested by ANOVA or Wilcoxon rank sums scores for continuous variables. Discrete variables were described by counts and percentages and tested with Fishers exact test.
The differences in event-free survival were compared by log-rank tests. A 2-sided P value <0.05 was considered statistically significant. To identify potential causative factors responsible for incomplete apposition, a multivariate analysis was performed including all the conventional pre, peri-, and postprocedural factors recorded in the frame of this trial.
| Results |
|---|
|
|
|---|
|
Follow-up IVUS was obtained in 80% (95 of 118) of the eligible patients. The analysis of the 2 groups within the IVUS population shows that the stent volumes were comparable. At follow-up, there was no difference in the TVV or PBS volume, suggesting that the eluted drug did not affect the plaque burden located outside the stent structure (Table 2).
|
The differences in neointimal hyperplasia and percent of volume obstruction between the 2 groups were highly significant, emphasizing the near complete abolition of the proliferative process inside the stent (Figure 2).
|
The analysis of the proximal and distal edge volumes showed no significant difference in EEM, lumen, and plaque volume at the proximal and distal edges (Table 2).
Qualitative assessment by IVUS did not reveal any evidence of intrastent thrombosis or persisting dissection at the stent edges, but showed a 21% incidence of incomplete apposition in the sirolimus group compared with a 4% incidence in the uncoated stent group. Table 3 provides a quantitative evaluation of the extent of incomplete apposition by the number of individual segments that were incompletely apposed, as well as their total length, maximal depth, circumferential extent, and volume of incomplete apposition. There was no significant difference between the 2 groups other than the frequency of the occurrence of this finding (21% versus 4%).
|
Correlation Between Quantitative Coronary Angiography and Incomplete Apposition Detected by IVUS
The binary restenosis rate and the late angiographic loss in the sirolimus group followed up with IVUS were 0% and 0.06±0.30 mm, respectively, whereas the restenosis rate and the late loss in the uncoated stent group were 23.4% and 0.91±0.58 mm.
The quantitative coronary angiography analysis of the 48 patients who received a sirolimus-eluting stent showed that the mean diameter of the stent segment remained unchanged 2.87±0.46 versus 2.87±0.49, whereas the mean diameter of the 47 patients treated with an uncoated stent decreased significantly from 2.90±0.42 to 2.17±0.48 (P<0.001). The mean diameter of the stents in the 10 patients who received a sirolimus-eluting stent and had incomplete apposition at follow-up was on average 3.16±0.57 mm and was significantly larger than the mean diameter of the stents of the 38 patients who had their stents well apposed at follow-up (2.79±0.43 mm, P<0.05). Incomplete apposition was more likely to occur in larger vessels. Stent diameter, however, was not used in the multivariate analysis of incomplete apposition.
Clinical Events at 1-Year Follow-Up
In the subset of patients (n=95) investigated with IVUS, the event-free survival rates at 1 year (98% in the sirolimus group versus 72% in the uncoated stent group, P<0.001) are very similar to the rates observed for the entire cohort of randomized patients (94% in the sirolimus group versus 72% in the uncoated stent group, P<0.0001). The 10 patients with incomplete stent apposition in the sirolimus group were asymptomatic and event-free at 1 year, whereas 1 of the 2 patients with incomplete apposition in the placebo group underwent percutaneous target lesion revascularization.
| Discussion |
|---|
|
|
|---|
The quantitative and qualitative assessments in this trial have demonstrated the absence of an edge effect in drug-eluting stents when compared with the placebo, the absence of persisting intimal tears at the stent edges, and the absence of parietal thrombi or "black holes" inside the stent.
Because of the initial report that there were more cases of late incomplete apposition detected by IVUS in the sirolimus group, this observation has created a great deal of interest. It therefore seemed important to evaluate this phenomenon carefully to determine whether there were any clinical sequelae to put it in the proper perspective. Because IVUS assessment of the completeness of apposition immediately after deployment was not performed, it is not possible to determine whether these few cases of incomplete apposition observed at follow-up are the result of late acquired malapposition or the consequence of an acute incomplete deployment. Therefore, we have used the broader term "incomplete apposition." The completeness of apposition may be highly dependent on the presence or absence of intravascular guidance at the time of deployment; in the FIM trial, performed with IVUS guidance, only 2 cases of late acquired malapposition at follow-up were recorded out of 45 patients enrolled in this pilot study. A 17% incidence of acute incomplete apposition has been reported in a recent series of 62 patients in which bare metal stent deployment, judged optimal by angiography, was systematically evaluated by IVUS. In the IVUS-guided trials Stent Treatment Region assessed by Ultrasound Tomography (STRUT) and Angiography-directed Versus IVUS-Directed coronary stent placement trial (AVID), the incidences of malapposition are 22% and 13%, respectively.20,21 Although the observed frequency of 21% in the sirolimus group is not very different from those reported with bare stents, it does not explain the difference seen between the 2 randomized groups in RAVEL.
Several purely speculative hypotheses may be raised to explain this general phenomenon. The first is that the antiproliferative action of the drug may preclude the growth of tissue in the void between struts and the vessel wall initially created by an incomplete deployment. The observation that larger vessels were more likely to exhibit this phenomenon seems to support this hypothesis. Second, the antimetabolite effect of the drug may induce phenomena such as necrosis or apoptosis, which may generate a new empty space between the struts and the vessel wall, which were originally in close contact. Third, the antimigratory and antiproliferative mechanism of action may prevent myoblasts from colonizing and proliferating in an organized thrombus (for example, in an unstable patient), which will dissolve at follow-up, creating a new empty space. A multivariate analysis considering conventional pre-, peri-, and postprocedural factors recorded in this trial did not identify any causative factors other than a large minimum luminal diameter after the procedure, elution of sirolimus, and absence of diabetes as predictors of incomplete apposition. The more proliferative nature of the healing process in the diabetic patients, although adequately inhibited by sirolimus (late loss 0.08 mm in diabetics), may be sufficient to fill in the gap between the sirolimus-eluting stents and the vessel wall when stents are initially incompletely deployed. This may explain why this finding was not present in any of the diabetics in this study.
Similar observations will undoubtedly be made with stents that elute drugs other than sirolimus. Serial IVUS observations from the first human experience with the QP2-eluting polymer stent system have indicated that mild incomplete stent apposition and persistent edge tears were observed in 5% and 10%, respectively, of the 20 cases studied in this registry,19 despite the fact that the dose of taxane analogue used in this registry seems to possess less potent antimigratory and antiproliferative properties than sirolimus (mean neointimal area of 1.16±1.35 mm2 versus of 0.09±0.26 mm2 in the present study). The angiographic late loss results reported for TAXUS I (a Feasibility Study Evaluating Safety of the NIRx Paclitaxel-Coated Conformer Coronary Stent for the Treatment of De Novo Coronary Lesions) (0.35±0.47 mm), the ASian Paclitaxel-Eluting stent Clinical Trial (ASPECT) study highest dose (0.29±0.72 mm) and European EvaLUation of PacliTaxel-Eluting Stents (ELUTES) highest dose (0.10± 0.68 mm), when the range of standard deviation is factored in, suggest the occurrence of negative late loss (or late gain) compatible with late malapposition in some patients, while at the same time suggesting in other patients substantially more neointimal hyperplasia than observed in the present study. The clinical significance of these observations in these trials remains to be determined.
It is of paramount importance to emphasize that in the sirolimus group, the incomplete apposition detected in some patients at 6 months did not translate into any subacute or late (1 year) clinical events. Furthermore, late (18-, 24-, and 36-month) IVUS investigation of cases of malapposition after brachytherapy has shown that this phenomenon may disappear at follow-up (unpublished data, personal communication of J. Ligthart, MSc, January, 2002). Therefore, the significance of this phenomenon may be trivial and clinically irrelevant, but longer-term follow-up will be necessary to answer this question definitively.
| Acknowledgments |
|---|
Received March 4, 2002; revision received May 22, 2002; accepted May 23, 2002.
| References |
|---|
|
|
|---|
2. Sousa JE, Costa MA, Abizaid AC, et al. Sustained suppression of neo-intimal proliferation by sirolimus-eluting stents: one-year angiographic and intravascular ultrasound follow-up. Circulation. 2001; 104: 20072011.
3. Morice MC, Serruys PW, Sousa JE, et al. A randomized comparison of a sirolimus-eluting stent with a standard stent for coronary revascularization. The RAVEL trial. N Engl J Med. 2002; 346: 17731780.
4. Marx SO, Marks AR. Bench to bedside: the development of rapamycin and its application to stent restenosis. Circulation. 2001; 104: 852855.
5. Albiero R, Nishida T, Adamian M, et al. Edge restenosis after implantation of high activity (32)P radioactive beta-emitting stents. Circulation. 2000; 101: 24542457.
6. Wardeh AJ, Knook AH, Kay IP, et al. Clinical and angiographical follow-up after implantation of a 612 micro Ci radioactive stent in patients with coronary artery disease. Eur Heart J. 2001; 22: 669675.
7. Kay IP, Sabate M, Van Langenhove G, et al. Outcome from balloon induced coronary artery dissection after intracoronary beta radiation. Heart. 2000; 83: 332337.
8. Kay IP, Sabate M, Costa MA, et al. Positive geometric vascular remodeling is seen after catheter-based radiation followed by conventional stent implantation but not after radioactive stent implantation. Circulation. 2000; 102: 14341439.
9. Sabate M, Serruys PW, van der Giessen WJ, et al. Geometric vascular remodeling after balloon angioplasty and beta- radiation therapy: a three-dimensional intravascular ultrasound study. Circulation. 1999; 100: 11821188.
10. Kozuma K, Costa MA, Sabate M, et al. Late stent malapposition occurring after intracoronary beta-irradiation detected by intravascular ultrasound. J Invas Cardiol. 1999; 11: 651655.[Medline] [Order article via Infotrieve]
11. Costa MA, Sabate M, van der Giessen WJ, et al. Late coronary occlusion after intracoronary brachytherapy. Circulation. 1999; 100: 789792.
12. Castagna MT, Mintz GS, Weissman N, et al. "Black hole": echolucent restenotic tissue after brachytherapy. Circulation. 2001; 103: 778.
13. Kay IP, Wardeh AJ, Kozuma K, et al. The pattern of restenosis and vascular remodeling after cold-end radioactive stent implantation. Eur Heart J. 2001; 22: 13111317.
14. Campeau L. Grading for angina pectoris. Circulation. 1976; 54: 522523.
15. Braunwald E. Unstable angina: a classification. Circulation. 1989; 80: 410414.
16. Serruys PW, Foley DP, de Feyter PJ, eds. Quantitative Coronary Angiography in Clinical Practice. Dordrecht, the Netherlands: Kluwer Academic Publishers; 1994.
17. Li W, von Birgelen C, Hartlooper A, et al. Semi-automated contour detection for volumetric quantification of intracoronary ultrasound.In: Computers in Cardiology. Washington, DC: IEEE Computer Society Press; 1994: 277280.
18. Von Birgelen C, di Mario C, Li W, et al. Morphometric analysis in three-dimensional intracoronary ultrasound an in vivo and in vitro study performed with a novel system for contour detection of lumen and plaque. Am Heart J. 1996; 132: 516527.[CrossRef][Medline] [Order article via Infotrieve]
19. Honda Y, Grube E, de la Fuente L, et al. Novel drug-delivery stent: intravascular ultrasound observations from the first human experience with the QP2-eluting polymer stent system. Circulation. 2001; 104: 380383.
20. Kobayashi Y, Honda Y, Christie LG, et al. Long-term vessel response to a self-expanding coronary stent: a serial volumetric intravascular ultrasound analysis from the ASSURE trial. J Am Coll Cardiol. 2001; 13291334:.
21. Uren NG, Schwarzacher SP, Metz JA, et al. Predictors and outcomes of stent thrombosis: an intravascular ultrasound registry. Eur Heart J. 2002; 23: 124132.
This article has been cited by other articles:
![]() |
P. Barlis, E. Regar, P. W. Serruys, K. Dimopoulos, W. J. van der Giessen, R.-J. M. van Geuns, G. Ferrante, S. Wandel, S. Windecker, G.-A. van Es, et al. An optical coherence tomography study of a biodegradable vs. durable polymer-coated limus-eluting stent: a LEADERS trial sub-study Eur. Heart J., January 2, 2010; 31(2): 165 - 176. [Abstract] [Full Text] [PDF] |
||||
![]() |
H. G. Bezerra, M. A. Costa, G. Guagliumi, A. M. Rollins, and D. I. Simon Intracoronary Optical Coherence Tomography: A Comprehensive Review: Clinical and Research Applications J. Am. Coll. Cardiol. Intv., November 1, 2009; 2(11): 1035 - 1046. [Abstract] [Full Text] [PDF] |
||||
![]() |
B. E. Claessen, M. A. Beijk, V. Legrand, W. Ruzyllo, A. Manari, O. Varenne, M. J. Suttorp, J. G.P. Tijssen, K. Miquel-Hebert, S. Veldhof, et al. Two-Year Clinical, Angiographic, and Intravascular Ultrasound Follow-Up of the XIENCE V Everolimus-Eluting Stent in the Treatment of Patients With De Novo Native Coronary Artery Lesions: The SPIRIT II Trial Circ Cardiovasc Interv, August 1, 2009; 2(4): 339 - 347. [Abstract] [Full Text] [PDF] |
||||
![]() |
Y. Suzuki, A. C. Yeung, and F. Ikeno The Pre-Clinical Animal Model in the Translational Research of Interventional Cardiology J. Am. Coll. Cardiol. Intv., May 1, 2009; 2(5): 373 - 383. [Abstract] [Full Text] [PDF] |
||||
![]() |
N. Gonzalo, P. Barlis, P. W. Serruys, H. M. Garcia-Garcia, Y. Onuma, J. Ligthart, and E. Regar Incomplete Stent Apposition and Delayed Tissue Coverage Are More Frequent in Drug-Eluting Stents Implanted During Primary Percutaneous Coronary Intervention for ST-Segment Elevation Myocardial Infarction Than in Drug-Eluting Stents Implanted for Stable/Unstable Angina: Insights From Optical Coherence Tomography J. Am. Coll. Cardiol. Intv., May 1, 2009; 2(5): 445 - 452. [Abstract] [Full Text] [PDF] |
||||
![]() |
C. Di Mario, G. R. Heyndrickx, F. Prati, and N. H.J. Pijls CHAPTER 8 Invasive Imaging and Haemodynamics ESC Textbook of Cardiovascular Medicine, January 1, 2009; 2(1): med-9780199566990-chapter - med-9780199566990-chapter. [Abstract] [Full Text] [PDF] |
||||
![]() |
L. O. Jensen, M. Maeng, P. Thayssen, E. H. Christiansen, K. N. Hansen, A. Galloe, H. Kelbaek, J. F. Lassen, and L. Thuesen Neointimal hyperplasia after sirolimus-eluting and paclitaxel-eluting stent implantation in diabetic patients: The Randomized Diabetes and Drug-Eluting Stent (DiabeDES) Intravascular Ultrasound Trial Eur. Heart J., November 2, 2008; 29(22): 2733 - 2741. [Abstract] [Full Text] [PDF] |
||||
![]() |
M. R. Patel and D. R. Holmes Jr Next-Generation Drug-Eluting Stents: A Spirited Step Forward or More of the Same JAMA, April 23, 2008; 299(16): 1952 - 1953. [Full Text] [PDF] |
||||
![]() |
J. Aoki, G. S. Mintz, N. J. Weissman, J. T. Mann, L. Cannon, J. Greenberg, E. Grube, A.R. Z. Masud, J. Koglin, L. Mandinov, et al. Chronic Arterial Responses to Overlapping Paclitaxel-Eluting Stents: Insights From Serial Intravascular Ultrasound Analyses in the TAXUS-V and -VI Trials J. Am. Coll. Cardiol. Intv., April 1, 2008; 1(2): 161 - 167. [Abstract] [Full Text] [PDF] |
||||
![]() |
Y. Suzuki, F. Ikeno, T. Koizumi, F. Tio, A. C. Yeung, P. G. Yock, P. J. Fitzgerald, and W. F. Fearon In Vivo Comparison Between Optical Coherence Tomography and Intravascular Ultrasound for Detecting Small Degrees of In-Stent Neointima After Stent Implantation J. Am. Coll. Cardiol. Intv., April 1, 2008; 1(2): 168 - 173. [Abstract] [Full Text] [PDF] |
||||
![]() |
R Hoffmann, M-C Morice, J W Moses, P J Fitzgerald, L Mauri, G Breithardt, J Schofer, P W Serruys, H-P Stoll, and M B Leon Impact of late incomplete stent apposition after sirolimus-eluting stent implantation on 4-year clinical events: intravascular ultrasound analysis from the multicentre, randomised, RAVEL, E-SIRIUS and SIRIUS trials Heart, March 1, 2008; 94(3): 322 - 328. [Abstract] [Full Text] [PDF] |
||||
![]() |
B. L. van der Hoeven, S.-S. Liem, J. W. Jukema, N. Suraphakdee, H. Putter, J. Dijkstra, D. E. Atsma, M. Bootsma, K. Zeppenfeld, P. V. Oemrawsingh, et al. Sirolimus-eluting stents versus bare-metal stents in patients with ST-segment elevation myocardial infarction: 9-month angiographic and intravascular ultrasound results and 12-month clinical outcome results from the MISSION! Intervention Study. J. Am. Coll. Cardiol., February 12, 2008; 51(6): 618 - 626. [Abstract] [Full Text] [PDF] |
||||
![]() |
F. Saia, A. Marzocchi, and A. Branzi Review: The safety of drug-eluting stents Therapeutic Advances in Cardiovascular Disease, February 1, 2008; 2(1): 43 - 52. [Abstract] [PDF] |
||||
![]() |
R. Jabara, N. Chronos, D. Conway, W. Molema, and K. Robinson Evaluation of a novel slow-release Paclitaxel-eluting stent with a bioabsorbable polymeric surface coating. J. Am. Coll. Cardiol. Intv., February 1, 2008; 1(1): 81 - 87. [Abstract] [Full Text] [PDF] |
||||
![]() |
P. S. Mullenix, S. R. Steele, M. J. Martin, B. W. Starnes, and C. A. Andersen C-reactive Protein Level and Traditional Vascular Risk Factors in the Prediction of Carotid Stenosis Arch Surg, November 1, 2007; 142(11): 1066 - 1071. [Abstract] [Full Text] [PDF] |
||||
![]() |
M.-C. Morice, P. W. Serruys, P. Barragan, C. Bode, G.-A. Van Es, H.-P. Stoll, D. Snead, L. Mauri, D. E. Cutlip, and E. Sousa Long-Term Clinical Outcomes With Sirolimus-Eluting Coronary Stents: Five-Year Results of the RAVEL Trial J. Am. Coll. Cardiol., October 2, 2007; 50(14): 1299 - 1304. [Abstract] [Full Text] [PDF] |
||||
![]() |
F. Airoldi, A. Colombo, N. Morici, A. Latib, J. Cosgrave, L. Buellesfeld, E. Bonizzoni, M. Carlino, U. Gerckens, C. Godino, et al. Incidence and Predictors of Drug-Eluting Stent Thrombosis During and After Discontinuation of Thienopyridine Treatment Circulation, August 14, 2007; 116(7): 745 - 754. [Abstract] [Full Text] [PDF] |
||||
![]() |
R. Jaffe and B. H. Strauss Late and Very Late Thrombosis of Drug-Eluting Stents: Evolving Concepts and Perspectives J. Am. Coll. Cardiol., July 10, 2007; 50(2): 119 - 127. [Abstract] [Full Text] [PDF] |
||||
![]() |
N. J. Weissman, S. G. Ellis, E. Grube, K. D. Dawkins, J. D. Greenberg, T. Mann, L. A. Cannon, P. A. Cambier, S. Fernandez, G. S. Mintz, et al. Effect of the polymer-based, paclitaxel-eluting TAXUS Express stent on vascular tissue responses: a volumetric intravascular ultrasound integrated analysis from the TAXUS IV, V, and VI trials Eur. Heart J., July 1, 2007; 28(13): 1574 - 1582. [Abstract] [Full Text] [PDF] |
||||
![]() |
S. Cook, P. Wenaweser, M. Togni, M. Billinger, C. Morger, C. Seiler, R. Vogel, O. Hess, B. Meier, and S. Windecker Incomplete Stent Apposition and Very Late Stent Thrombosis After Drug-Eluting Stent Implantation Circulation, May 8, 2007; 115(18): 2426 - 2434. [Abstract] [Full Text] [PDF] |
||||
![]() |
E. Camenzind, P. G. Steg, and W. Wijns A Cause for Concern Circulation, March 20, 2007; 115(11): 1440 - 1455. [Full Text] [PDF] |
||||
![]() |
M. Takano, T. Ohba, S. Inami, K. Seimiya, S. Sakai, and K. Mizuno Angioscopic differences in neointimal coverage and in persistence of thrombus between sirolimus-eluting stents and bare metal stents after a 6-month implantation Eur. Heart J., September 2, 2006; 27(18): 2189 - 2195. [Abstract] [Full Text] [PDF] |
||||
![]() |
G. S. Mintz and N. J. Weissman Intravascular Ultrasound in the Drug-Eluting Stent Era J. Am. Coll. Cardiol., August 1, 2006; 48(3): 421 - 429. [Abstract] [Full Text] [PDF] |
||||
![]() |
P. W. Serruys, M. J.B. Kutryk, and A. T.L. Ong Coronary-Artery Stents N. Engl. J. Med., February 2, 2006; 354(5): 483 - 495. [Full Text] [PDF] |
||||
![]() |
C.-H. Lee, H.-C. Tan, and Y.-T. Lim Update on Drug-Eluting Stents for Prevention of Restenosis Asian Cardiovasc Thorac Ann, February 1, 2006; 14(1): 75 - 82. [Abstract] [Full Text] [PDF] |
||||
![]() |
M.-K. Hong, G. S. Mintz, C. W. Lee, D.-W. Park, K.-M. Park, B.-K. Lee, Y.-H. Kim, J.-M. Song, K.-H. Han, D.-H. Kang, et al. Late Stent Malapposition After Drug-Eluting Stent Implantation: An Intravascular Ultrasound Analysis With Long-Term Follow-Up Circulation, January 24, 2006; 113(3): 414 - 419. [Abstract] [Full Text] [PDF] |
||||
![]() |
I. Fishbein, I. S. Alferiev, O. Nyanguile, R. Gaster, J. M. Vohs, G. S. Wong, H. Felderman, I-W. Chen, H. Choi, R. L. Wilensky, et al. Bisphosphonate-mediated gene vector delivery from the metal surfaces of stents PNAS, January 3, 2006; 103(1): 159 - 164. [Abstract] [Full Text] [PDF] |
||||
![]() |
J. Aoki, A. Colombo, D. Dudek, A. P. Banning, J. Drzewiecki, K. Zmudka, F. Schiele, M. E. Russell, J. Koglin, P. W. Serruys, et al. Peristent Remodeling and Neointimal Suppression 2 Years After Polymer-Based, Paclitaxel-Eluting Stent Implantation: Insights From Serial Intravascular Ultrasound Analysis in the TAXUS II Study Circulation, December 20, 2005; 112(25): 3876 - 3883. [Abstract] [Full Text] [PDF] |
||||
![]() |
J. Aoki, A. C. Abizaid, P. W. Serruys, A. T.L. Ong, E. Boersma, J. E. Sousa, and N. Bruining Evaluation of Four-Year Coronary Artery Response After Sirolimus-Eluting Stent Implantation Using Serial Quantitative Intravascular Ultrasound and Computer-Assisted Grayscale Value Analysis for Plaque Composition in Event-Free Patients J. Am. Coll. Cardiol., November 1, 2005; 46(9): 1670 - 1676. [Abstract] [Full Text] [PDF] |
||||
![]() |
J. Ako, Y. Morino, Y. Honda, A. Hassan, S. Sonoda, P. G. Yock, M. B. Leon, J. W. Moses, H. N. Bonneau, and P. J. Fitzgerald Late Incomplete Stent Apposition After Sirolimus-Eluting Stent Implantation: A Serial Intravascular Ultrasound Analysis J. Am. Coll. Cardiol., September 20, 2005; 46(6): 1002 - 1005. [Abstract] [Full Text] [PDF] |
||||
![]() |
M. Togni, S. Windecker, R. Cocchia, P. Wenaweser, S. Cook, M. Billinger, B. Meier, and O. M. Hess Sirolimus-Eluting Stents Associated With Paradoxic Coronary Vasoconstriction J. Am. Coll. Cardiol., July 19, 2005; 46(2): 231 - 236. [Abstract] [Full Text] [PDF] |
||||
![]() |
P. W. Serruys, G. Sianos, A. Abizaid, J. Aoki, P. den Heijer, H. Bonnier, P. Smits, D. McClean, S. Verheye, J. Belardi, et al. The Effect of Variable Dose and Release Kinetics on Neointimal Hyperplasia Using a Novel Paclitaxel-Eluting Stent Platform: The Paclitaxel In-Stent Controlled Elution Study (PISCES) J. Am. Coll. Cardiol., July 19, 2005; 46(2): 253 - 260. [Abstract] [Full Text] [PDF] |
||||
![]() |
B. Balakrishnan, A. R. Tzafriri, P. Seifert, A. Groothuis, C. Rogers, and E. R. Edelman Strut Position, Blood Flow, and Drug Deposition: Implications for Single and Overlapping Drug-Eluting Stents Circulation, June 7, 2005; 111(22): 2958 - 2965. [Abstract] [Full Text] [PDF] |
||||
![]() |
N. J. Weissman, J. Koglin, D. A. Cox, J. Hermiller, C. O'Shaughnessy, J. T. Mann, M. Turco, R. Caputo, P. Bergin, J. Greenberg, et al. Polymer-based paclitaxel-eluting stents reduce in-stent neointimal tissue proliferation: A serial volumetric intravascular ultrasound analysis from the TAXUS-IV trial J. Am. Coll. Cardiol., April 19, 2005; 45(8): 1201 - 1205. [Abstract] [Full Text] [PDF] |
||||
![]() |
T. W. Johnson, Y. X. Wu, C. Herdeg, A. Baumbach, A. C. Newby, K. R. Karsch, and M. Oberhoff Stent-Based Delivery of Tissue Inhibitor of Metalloproteinase-3 Adenovirus Inhibits Neointimal Formation in Porcine Coronary Arteries Arterioscler Thromb Vasc Biol, April 1, 2005; 25(4): 754 - 759. [Abstract] [Full Text] [PDF] |
||||
![]() |
K. Tanabe, P. W. Serruys, M. Degertekin, E. Grube, G. Guagliumi, W. Urbaszek, J. Bonnier, J.-M. Lablanche, T. Siminiak, J. Nordrehaug, et al. Incomplete Stent Apposition After Implantation of Paclitaxel-Eluting Stents or Bare Metal Stents: Insights From the Randomized TAXUS II Trial Circulation, February 22, 2005; 111(7): 900 - 905. [Abstract] [Full Text] [PDF] |
||||
![]() |
Y.-X. Chen, X. Ma, S. Whitman, and E. R. O'Brien Novel Antiinflammatory Vascular Benefits of Systemic and Stent-Based Delivery of Ethylisopropylamiloride Circulation, December 14, 2004; 110(24): 3721 - 3726. [Abstract] [Full Text] [PDF] |
||||
![]() |
G. J. Murphy, A. J. Bryan, and G. D. Angelini Hybrid Coronary Revascularization in the Era of Drug-Eluting Stents Ann. Thorac. Surg., November 1, 2004; 78(5): 1861 - 1867. [Abstract] [Full Text] [PDF] |
||||
![]() |
P. W. Serruys, J. A. Ormiston, G. Sianos, J. E. Sousa, E. Grube, P. den Heijer, P. de Feyter, P. Buszman, A. Schomig, J. Marco, et al. Actinomycin-eluting stent for coronary revascularization: A randomized feasibility and safety study: The ACTION trial J. Am. Coll. Cardiol., October 6, 2004; 44(7): 1363 - 1367. [Abstract] [Full Text] [PDF] |
||||
![]() |
R. Waksman, A. E. Ajani, A. D. Pichard, R. Torguson, E. Pinnow, D. Canos, L. F. Satler, K. M. Kent, P. Kuchulakanti, C. Pappas, et al. Oral rapamycin to inhibit restenosis after stenting of de novo coronary lesions: The Oral Rapamune to Inhibit Restenosis (ORBIT) study J. Am. Coll. Cardiol., October 6, 2004; 44(7): 1386 - 1392. [Abstract] [Full Text] [PDF] |
||||
![]() |
A. J Carter, M. Aggarwal, G. A Kopia, F. Tio, P. S Tsao, R. Kolata, A. C Yeung, G. Llanos, J. Dooley, and R. Falotico Long-term effects of polymer-based, slow-release, sirolimus-eluting stents in a porcine coronary model Cardiovasc Res, September 1, 2004; 63(4): 617 - 624. [Abstract] [Full Text] [PDF] |
||||
![]() |
P. W. Serruys, W. Wijns, G. Sianos, I. de Scheerder, P. A. van den Heuvel, W. Rutsch, H. D. Glogar, C. Macaya, P. H. Materne, S. Veldhof, et al. Direct stenting versus direct stenting followed by centered beta-radiation with intravascular ultrasound-guided dosimetry and long-term anti-platelet treatment: Results of a randomized trial: Beta-radiation Investigation with Direct stenting and Galileo in Europe (BRIDGE) J. Am. Coll. Cardiol., August 4, 2004; 44(3): 528 - 537. [Abstract] [Full Text] [PDF] |
||||
![]() |
J. R Sindermann, V. Verin, J. W Hopewell, H. P. Rodemann, and J. H Hendry Biological aspects of radiation and drug-eluting stents for the prevention of restenosis Cardiovasc Res, July 1, 2004; 63(1): 22 - 30. [Abstract] [Full Text] [PDF] |
||||
![]() |
T. Schachner, Y. Zou, A. Oberhuber, A. Tzankov, T. Mairinger, G. Laufer, and J. O. Bonatti Local application of rapamycin inhibits neointimal hyperplasia in experimental vein grafts Ann. Thorac. Surg., May 1, 2004; 77(5): 1580 - 1585. [Abstract] [Full Text] [PDF] |
||||
![]() |
J. L. Orford, A. Lerman, and D. R. Holmes Routine intravascular ultrasound guidance of percutaneous coronary intervention: A critical reappraisal J. Am. Coll. Cardiol., April 21, 2004; 43(8): 1335 - 1342. [Abstract] [Full Text] [PDF] |
||||
![]() |
E M Wong, C Pawsey, and H C Lowe Evidence for "lumen sealing" with sirolimus eluting stents in the treatment of complex coronary artery dissection Heart, March 1, 2004; 90(3): e13 - 13. [Abstract] [Full Text] [PDF] |
||||
![]() |
A. J. Chaves, A. G.M.R. Sousa, L. A. Mattos, A. Abizaid, R. Staico, F. Feres, M. Centemero, L. F. Tanajura, A. Abizaid, I. Pinto, et al. Volumetric Analysis of In-Stent Intimal Hyperplasia in Diabetic Patients Treated With or Without Abciximab: Results of the Diabetes Abciximab steNT Evaluation (DANTE) Randomized Trial Circulation, February 24, 2004; 109(7): 861 - 866. [Abstract] [Full Text] [PDF] |
||||
![]() |
M.-K. Hong, G. S. Mintz, C. W. Lee, Y.-H. Kim, S.-W. Lee, J.-M. Song, K.-H. Han, D.-H. Kang, J.-K. Song, J.-J. Kim, et al. Incidence, Mechanism, Predictors, and Long-Term Prognosis of Late Stent Malapposition After Bare-Metal Stent Implantation Circulation, February 24, 2004; 109(7): 881 - 886. [Abstract] [Full Text] [PDF] |
||||
![]() |
D. R. Holmes Jr, B. G. Firth, and D. L. Wood Paradigm shifts in cardiovascular medicine J. Am. Coll. Cardiol., February 18, 2004; 43(4): 507 - 512. [Abstract] [Full Text] [PDF] |
||||
![]() |
R. Virmani, G. Guagliumi, A. Farb, G. Musumeci, N. Grieco, T. Motta, L. Mihalcsik, M. Tespili, O. Valsecchi, and F. D. Kolodgie Localized Hypersensitivity and Late Coronary Thrombosis Secondary to a Sirolimus-Eluting Stent: Should We Be Cautious? Circulation, February 17, 2004; 109(6): 701 - 705. [Abstract] [Full Text] [PDF] |
||||
![]() |
M. Degertekin, P. A. Lemos, C. H. Lee, K. Tanabe, J.E. Sousa, A. Abizaid, E. Regar, G. Sianos, W. J. van der Giessen, P. J. de Feyter, et al. Intravascular ultrasound evaluation after sirolimus eluting stent implantation for de novo and in-stent restenosis lesions Eur. Heart J., January 1, 2004; 25(1): 32 - 38. [Abstract] [Full Text] [PDF] |
||||
![]() |
V Bhatia, R Bhatia, and M Dhindsa Drug-eluting stents: new era and new concerns Postgrad. Med. J., January 1, 2004; 80(939): 13 - 18. [Abstract] [Full Text] [PDF] |
||||
![]() |
M. Degertekin, P. W. Serruys, K. Tanabe, C. H. Lee, J. E. Sousa, A. Colombo, M.-C. Morice, J. M.R. Ligthart, and P. J. de Feyter Long-Term Follow-Up of Incomplete Stent Apposition in Patients Who Received Sirolimus-Eluting Stent for De Novo Coronary Lesions: An Intravascular Ultrasound Analysis Circulation, December 2, 2003; 108(22): 2747 - 2750. [Abstract] [Full Text] [PDF] |
||||
![]() |
G. S. Mintz, A. Tinana, M.-K. Hong, C. W. Lee, J.-J. Kim, N. E. Fearnot, S.-W. Park, S.-J. Park, and N. J. Weissman Impact of Preinterventional Arterial Remodeling on Neointimal Hyperplasia After Implantation of (Non-Polymer-Encapsulated) Paclitaxel-Coated Stents: A Serial Volumetric Intravascular Ultrasound Analysis From the ASian Paclitaxel-Eluting Stent Clinical Trial (ASPECT) Circulation, September 16, 2003; 108(11): 1295 - 1298. [Abstract] [Full Text] [PDF] |
||||
![]() |
P. A. Lemos, P. W. Serruys, and J. E. Sousa Drug-Eluting Stents: Cost Versus Clinical Benefit Circulation, June 24, 2003; 107(24): 3003 - 3007. [Full Text] [PDF] |
||||
![]() |
W. W. O'Neill and M. B. Leon Drug-Eluting Stents: Costs Versus Clinical Benefit Circulation, June 24, 2003; 107(24): 3008 - 3011. [Full Text] [PDF] |
||||
![]() |
G. S. Mintz, V. M. Shah, and N. J. Weissman Regional Remodeling as the Cause of Late Stent Malapposition Circulation, June 3, 2003; 107(21): 2660 - 2663. [Abstract] [Full Text] [PDF] |
||||
![]() |
D. F. Denny Jr Prediction of Restenosis after Carotid Artery Stent Implantation Radiology, May 1, 2003; 227(2): 316 - 318. [Full Text] [PDF] |
||||
![]() |
M.-K. Hong, G. S. Mintz, C. W. Lee, J.-M. Song, K.-H. Han, D.-H. Kang, J.-K. Song, J.-J. Kim, N. J. Weissman, N. E. Fearnot, et al. Paclitaxel Coating Reduces In-Stent Intimal Hyperplasia in Human Coronary Arteries: A Serial Volumetric Intravascular Ultrasound Analysis From the ASian Paclitaxel-Eluting Stent Clinical Trial (ASPECT) Circulation, February 4, 2003; 107(4): 517 - 520. [Abstract] [Full Text] [PDF] |
||||
![]() |
R Virmani, F D Kolodgie, A Farb, and A Lafont Drug eluting stents: are human and animal studies comparable? Heart, February 1, 2003; 89(2): 133 - 138. [Abstract] [Full Text] [PDF] |
||||
![]() |
M. N. Babapulle and M. J. Eisenberg Coated Stents for the Prevention of Restenosis: Part II Circulation, November 26, 2002; 106(22): 2859 - 2866. [Full Text] [PDF] |
||||
![]() |
V. M. Shah, G. S. Mintz, S. Apple, and N. J. Weissman Background Incidence of Late Malapposition After Bare-Metal Stent Implantation Circulation, October 1, 2002; 106(14): 1753 - 1755. [Abstract] [Full Text] [PDF] |
||||
| |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
|
Circulation Home | Subscriptions | Archives | Feedback | Authors | Help | AHA Journals Home | Search Copyright © 2002 American Heart Association, Inc. All rights reserved. Unauthorized use prohibited. |