Donate Help Contact The AHA Sign In Home
American Heart Association
Circulation
Search: search_blue_button Advanced Search
Circulation. 2002;106:511-515
Published online before print July 1, 2002, doi: 10.1161/01.CIR.0000023621.88708.62
This Article
Right arrow Abstract Freely available
Right arrow Full Text (PDF)
Right arrow Data Supplement
Right arrow All Versions of this Article:
106/4/511    most recent
01.CIR.0000023621.88708.62v1
Right arrow Alert me when this article is cited
Right arrow Alert me if a correction is posted
Right arrow Citation Map
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Download to citation manager
Right arrow Request Permissions
Citing Articles
Right arrow Citing Articles via HighWire
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Buecker, A.
Right arrow Articles by Günther, R. W.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Buecker, A.
Right arrow Articles by Günther, R. W.
Right arrowPubmed/NCBI databases
Medline Plus Health Information
*MRI Scans
Related Collections
Right arrow Cardiac development
Right arrow Catheter-based coronary and valvular interventions: other

(Circulation. 2002;106:511.)
© 2002 American Heart Association, Inc.


Basic Science Reports

Magnetic Resonance–Guided Placement of Atrial Septal Closure Device in Animal Model of Patent Foramen Ovale

Arno Buecker, MD; Elmar Spuentrup, MD; Ralph Grabitz, MD; Franz Freudenthal, MD; Eberhard G. Muehler, MD; Tobias Schaeffter, PhD; Joop J. van Vaals, PhD; Rolf W. Günther, MD

From the Clinic of Diagnostic Radiology (A.B., E.S., F.F., R.W.G.) and the Clinic of Pediatric Cardiology (E.G.M.), University of Technology Aachen, Aachen, Germany; the Department of Pediatric Cardiology (R.G.), Kiel University, Kiel, Germany; Philips Research Laboratories (T.S.), Hamburg, Germany; and Philips Medical Systems (J.J.v.V.), Best, the Netherlands.

Correspondence to Arno Buecker, MD, Clinic of Diagnostic Radiology, Pauwelsstr. 30, D-52057 Aachen, Germany. E-mail buecker{at}rad.rwth-aachen.de


*    Abstract
up arrowTop
*Abstract
down arrowIntroduction
down arrowMethods
down arrowResults
down arrowDiscussion
down arrowReferences
 
Background Percutaneous closure of the patent foramen ovale (PFO) is usually performed under x-ray in combination with ultrasound guidance. We tested the feasibility of applying magnetic resonance (MR) guidance for percutaneous closure of PFO in an animal model, thus avoiding the disadvantage of ionizing radiation.

Methods and Results Real-time MRI with radial or spiral k-space filling (15 frames per second) on an interventional 1.5-T high-field whole-body system was exploited to examine the feasibility of MR-guided closure of the PFO in 7 piglets weighing {approx}14 kg. A specially designed prototype nonmagnetic closure device was introduced via the femoral vein. The short bore of the magnet and in-room monitors allowed for visualization and steering of the catheter with the loaded occluder. Catheterization of the left atrium and, finally, correct placement of the device was possible in all animals. Deployment of the device was depicted by real-time MR, and initial misplacement, which occurred in 2 animals, was easily detected and corrected.

Conclusions Real-time MR guidance of PFO closure, without the use of ionizing radiation, is feasible in an animal model.


Key Words: magnetic resonance imaging • catheterization • defects


*    Introduction
up arrowTop
up arrowAbstract
*Introduction
down arrowMethods
down arrowResults
down arrowDiscussion
down arrowReferences
 
Percutaneous closure of patent foramen ovale or atrial septal defects is becoming an increasingly accepted alternative to surgical repair. Placement of the different available devices is usually performed under combined x-ray and transesophageal echocardiographic guidance. A reduction in the amount of radiation might be especially advantageous for pediatric patients.1,2 Consequently, atrial septal defect closure has been attempted mainly with the use of transesophageal echocardiography for guidance.3 Ewert et al4 were able to completely abandon x-ray guidance and to exploit transesophageal echocardiography in children,4 albeit at the cost of higher propofol doses for sedation. Because the quality of real-time magnetic resonance (MR) has improved sufficiently for application in the field of vascular interventions,5 we designed the present study to investigate the use of real-time MR guidance for the closure of patent foramen ovale in an animal model.


*    Methods
up arrowTop
up arrowAbstract
up arrowIntroduction
*Methods
down arrowResults
down arrowDiscussion
down arrowReferences
 
Animal Model
The official committee for animal affairs gave approval for the animal experiments. Experiments were performed on 7 domestic farm piglets (Germany) with an average body weight (bw) of 14 kg (ranging from 12.5 to 17.5 kg). After intramuscularly applied premedication of 0.5 mL atropine per 10 kg bw, 2 mL azaperone per 10 kg bw, and 1 mL ketamine per 10 kg bw, pentobarbital solution diluted 1:3 with saline was injected as needed via a venous access line placed in an ear vein. The animals were intubated and mechanically ventilated. General anesthesia, including mechanical ventilation, was maintained during the whole procedure, including the MR-guided placement of the septal occluder. The age of the animals was chosen to allow for easy passage through the usually patent foramen ovale.

MR Scanner and Real-Time Imaging Sequence
The interventions were performed on a dedicated interventional 1.5-T ACS-NT MR scanner (Philips Medical Systems). X-ray control of the MR-guided interventions was performed by a specially shielded C-arm unit positioned in the same room with the MR scanner. LCD screens beside the magnet enabled direct control of the MR-guided intervention. A remote control was used to change the image plane, orientation, and angulation as required during the procedure. Specially designed real-time reconstruction hardware (Philips Research Laboratories) performed the real-time gridding interpolation of the raw data, consequently allowing standard fast Fourier reconstruction of the images also in real time.6 A 5-element synergy cardiac coil was used for signal acquisition.

Real-time MR image data acquisition was achieved by applying a gradient echo sequence with either radial (repetition time [TR] 2.5 ms, echo time [TE] 1.2 ms, flip angle 45°, field of view 300 mm2, matrix 128x256, slice thickness 10 mm, and 80 radials) or spiral (TR 30 ms, TE 4 ms, flip angle 40°, field of view 250 mm2, matrix 1282, slice thickness 10 mm, and 4 spirals) k-space filling. Additionally, the sliding window reconstruction technique7 was applied, yielding a frame rate of 15 images per second. This technique, also called view sharing or echo sharing, uses partially old and partially new data to calculate the next frame, yielding a higher frame rate compared with the acquisition time of 1 completely new MR image, which was 200 ms for radial scanning (5 frames per second) and 120 ms for spiral scanning (8.3 frames per second).

Atrial Septal Occluder and MR-Guided Intervention
Self-made nonmagnetic prototypes of atrial septal occluders made of nitinol were used because they were favorably depicted during in vitro experiments applying real-time MRI sequences.8 The occluder consists of 2 connected button halves, one or both of which can be applied with a membrane (Figure 1). The system runs over a 0.25-mm nitinol guidewire. In addition, it is fixed by one 0.15-mm nitinol guidewire, which allowed us to perform the "Minnesota wiggle" procedure9 and, in conjunction with a small nitinol tube (1 mm), to recapture the occluder into the delivery catheter. The whole system as described passes through a 2.7-mm (8F) delivery catheter.



View larger version (88K):
[in this window]
[in a new window]
 
Figure 1. Self-made occluder consisting of 2 connected halves, which can be individually covered with a membrane. Delivery can be accomplished with 0.9-mm guidewire. Eyelets (arrow) allow for fixation of 2 small nitinol wires, enabling wiggling maneuver after occluder placement as well as recapture of device.

A 3.3-mm (10F) introducer sheath was placed in the right femoral vein by the Seldinger technique. Next, the left atrium was catheterized through the foramen ovale. In the first animal, a 17.5-kg piglet, the foramen was not patent, and an artificial opening had to be created by use of a transjugular portosystemic shunt needle (Cook) and dilation with a 12-mm balloon catheter. In all other animals, it was easily possible to pass the atrial septum through the patent foramen ovale with a 1.6-mm (5F) multipurpose catheter and to secure the path with a 0.9-mm (0.035-in) nitinol guidewire. These procedures were performed under x-ray guidance in the first 4 animals and purely under MR guidance in the last 3 animals. The general imaging plane for the intervention was chosen on a parasagittal plane along the orientation of the catheter to contain the inferior vena cava and the right and the left atria (Figure 2). In the first 4 animals, the mounted occluder was advanced under MR guidance over a guidewire previously positioned under x-ray guidance into the left atrium. In the last 3 animals, catheterization of the left atrium was performed under MR guidance, steering the catheter with a loaded occluder through the foramen ovale (Figure 3, Movie I [representative image quality for all experiments]). All occluders were deployed and positioned over the foramen ovale solely under MR guidance (Figure 4, Movie I). The position of each device as determined by real-time MR was confirmed by x-ray. Correct positioning of the device was tested under MR by wiggling the still connected occluder. Free movement in the right or left atrium without movement of the septum was considered as misplacement, with both halves of the occluder either in the right or left atrium. This was proved by the same wiggle maneuver as performed under x-ray guidance (Figure 5). If misplacement occurred, the occluder was recaptured and replaced.



View larger version (80K):
[in this window]
[in a new window]
 
Figure 2. a, Diagram of a parasagittal real-time MR image after occluder placement (white arrow), indicating planning of slice orientation generally used for control of intervention yielding para-axial image (b). Orientation in panel a results in para-axial image showing part of vena cava inferior (curved arrow), atrial septum (white arrow), aortic valve (star), and both ventricles. Catheter tip is located in right ventricle (RV). LV indicates left ventricle; LA, left atrium.



View larger version (109K):
[in this window]
[in a new window]
 
Figure 3. MR images grabbed from continuously acquired real-time MR data. Tip of catheter-loaded occluder can easily be depicted (arrows). It is steered from right ventricle (a) to the right atrium (b), turned against the septum (c), maneuvered through the foramen ovale (d), and advanced forward through the left atrium (e) into the left atrial appendage (f).



View larger version (165K):
[in this window]
[in a new window]
 
Figure 4. Real-time MR images showing deployment of occluder and its positioning over foramen ovale. After opening of first half of occluder in left atrial appendage (a), occluder is pulled back against atrial septum (b), and second half is set free in right atrium (c). X-ray image (d) verifies configuration of occluder as seen on real-time MR image (c). Difference in visualized waist of occluder is because x-ray image was grabbed during wiggle procedure, showing a more stretched occluder at this time.



View larger version (113K):
[in this window]
[in a new window]
 
Figure 5. Real-time MR images showing wiggle maneuver after incorrect occluder placement in right atrium. Despite smallness of the right atrium, this was easily appreciated on real-time MR movie.

MR images of the occluder were obtained by applying a fast, navigator-gated, free-breathing, segmented k-space, cardiac-triggered, 3D, true fast imaging with steady state precession (FISP) sequence (TR 3.9 ms, TE 1.9 ms, flip angle 75°, resolution 1.2x1.2 mm2, slice thickness 1.5 mm, 16 slices, and acquisition time <2 minutes [triggering included]) (Figure 6). Finally, the animals were euthanized, and their hearts were removed and opened to macroscopically inspect the occluder position.



View larger version (130K):
[in this window]
[in a new window]
 
Figure 6. Axial, fast, 3D, MR image clearly showing relation of occluder (straight arrow) to pulmonary vein (curved arrow).


*    Results
up arrowTop
up arrowAbstract
up arrowIntroduction
up arrowMethods
*Results
down arrowDiscussion
down arrowReferences
 
Correct occluder placement with closure of the foramen ovale was achieved in all cases. MRI time for occluder deployment ranged from 8 minutes to 17 minutes (mean 10 minutes). This does not include the time needed for x-ray control during the interventional procedure. Susceptibility artifacts on the real-time MR images caused by the mounted occluder allowed visualization of the delivery catheter and, thereby, catheterization of the left atrium (Figure 3). Deployment of the occluder could be depicted as well (Figure 4), enabling correct occluder placement in all cases. Both halves of the occluder could be discerned on the real-time images, because the artifacts caused by the occluder were small enough (Figure 4c). Correct positioning of the occluder was tested by wiggling the occluder (Movie II). This wiggling maneuver revealed initial misplacement in 2 cases, once in the right and once in the left atrium (Figure 5, Movie II). Incorrect placement was suspected but not clearly visible on the real-time MR images, because the interatrial septum could not be clearly visualized in relation to the occluder. Real-time MR observation of the wiggle maneuver clearly demonstrated the misplacements in either atrium, and it was easily possible to recapture the occluder and replace it correctly. After each deployment, the occluder position as seen by real-time MR was controlled by x-ray and proved to be correct. Finally, the correct occluder position and its relation to the pulmonary veins and mitral valve was certified in all cases by fast 3D MRI (Figure 6) and macroscopic examination of the ex vivo heart.


*    Discussion
up arrowTop
up arrowAbstract
up arrowIntroduction
up arrowMethods
up arrowResults
*Discussion
down arrowReferences
 
Previously, the slow data acquisition of MR has been a major disadvantage. For diagnostic imaging of the constantly moving heart, this has been overcome by special imaging techniques combined with cardiac and respiratory triggering. Furthermore, real-time imaging capabilities have been developed, thus enabling MR guidance of vascular5,10 and cardiac11,12 interventions in animals. The present study was designed to test the applicability of real-time MRI techniques to guide the transcatheter placement of atrial septal occluders. We used self-made prototypes of nonmagnetic devices, including the delivery system. This was achieved by manufacturing all metallic parts from nitinol and using an introducer catheter without any metallic braiding (Figure 1). The occluder device was well visible on both real-time MRI sequences. While it was mounted in the deployment catheter, it created an artifact, which enabled depiction and guidance of the catheter (Figure 3). The imaging speed of 15 frames per second was sufficient for direct control of the instruments under MR guidance. Deployment of the 2 occluder halves was also clearly visible (Figure 4), but the button size of the occluder prototype, which was available with a fixed diameter of 20 mm only, usually obscured the anatomy of the atrial septum. Although this was of no negative consequences in the present study, the use of relatively large occluders for patients with large atrial septal defects could cause difficulties in depiction of the adjacent anatomic structures with the current occluder device. However, the size of susceptibility artifacts caused by the occluder could be further reduced by using different metal alloys.13 Nonetheless, in consideration of the given artifacts of the occluder, it can be expected that residual leakage through the atrial septum after occluder placement can be detected.14 A disadvantage of our animal model is the lack of a real septal defect and the fact that no shunt was to be expected because of the lack of any pressure gradient between the atria. Therefore, we neither tried to depict the atrial septal defect or shunt directly on anatomic or flow images by MR nor did we look for a remaining shunt after occluder placement.

Correct occluder placement was determined by a wiggle procedure identical to that (Minnesota wiggle) carried out under x-ray fluoroscopy9 (Figure 5, Movie II). If misplacement occurred, the occluder was recaptured into the delivery catheter and reinserted successfully under MR guidance and confirmed by wiggle procedures performed under x-ray fluoroscopy and macroscopically in the ex vivo heart specimens

The tomographic nature of MR made it important to choose a suitable imaging plane for control of the procedure. Because we wanted to visualize the advancing catheter as well as the atrial septum, we planned an imaging plane including the inferior vena cava and both atria. Planning was performed on a parasagittal slice, as shown in Figure 2. The resulting para-axial image contained parts of all heart chambers and the aortic valve. Slight adjustments of this imaging plane were made during the procedure by moving the imaging plane parallel to the originally planned slice. Because of the interactive abilities of the interventional MR scanner, this was possible as required, without any significant time delay. The fully anesthetized animals did not inadvertently move, but the interactive abilities can be expected to be sufficient for quick slice repositioning in a clinical setting, where patient motion might occur.

The present study demonstrates the general feasibility of artifact-free real-time MRI of the heart, enabling MR-guided placement of an atrial septal occluder. Neither cardiac nor respiratory triggering nor breath-holding was necessary to achieve high-contrast images of the heart chambers. The occluder was depicted passively by susceptibility artifacts, which are due to the different magnetization of the metal nitinol compared with tissue.15 An advantage of MR compared with x-ray fluoroscopy is the lack of exposure of the patient and technician to ionizing radiation. Furthermore, the depiction of the heart anatomy shows the relation of the occluder to the atrial septum, pulmonary veins, and atrioventricular valves. The value of MR compared with echocardiography, which already has been shown to be applicable to the procedure in clinical studies,4 remains to be examined. The high costs of an MR scanner, the ability to deal with complications such as loss of the occluder, and use of a cardioverter close to the MR scanner have to be considered. Furthermore, the use of metallic nitinol instruments, which can at least in theory act as antennas and consequently heat up during the MR experiment,16 has to be thoroughly examined in septal occluder systems before clinical trials can be undertaken. Nonetheless, the experiments show the general feasibility of real-time MR guidance for cardiac interventions with a sufficient imaging speed and contrast.

In conclusion, high quality real-time MRI of the heart allows MR guidance of transcatheter patent foramen ovale occlusion in an animal model.


*    Footnotes
 
Movies I and II are available in an online-only Data Supplement at http://www.circulationaha.org.

Received March 20, 2002; revision received May 1, 2002; accepted May 2, 2002.


*    References
up arrowTop
up arrowAbstract
up arrowIntroduction
up arrowMethods
up arrowResults
up arrowDiscussion
*References
 

  1. Brenner DJ, Elliston CD, Hall EJ, et al. Estimated risks of radiation-induced fatal cancer from pediatric CT. AJR Am J Roentgenol. 2001; 176: 289–296.[Abstract/Free Full Text]
  2. Brown PH, Thomas RD, Silberberg PJ, et al. Optimization of a fluoroscope to reduce radiation exposure in pediatric imaging. Pediatr Radiol. 2000; 30: 229–235.[CrossRef][Medline] [Order article via Infotrieve]
  3. Tseng HC, Hsiao PN, Lin YH, et al. Transesophageal echocardiographic monitoring for transcatheter closure of atrial septal defect. J Formos Med Assoc. 2000; 99: 684–688.[Medline] [Order article via Infotrieve]
  4. Ewert P, Berger F, Daehnert I, et al. Transcatheter closure of atrial septal defects without fluoroscopy: feasibility of a new method. Circulation. 2000; 101: 847–849.[Abstract/Free Full Text]
  5. Buecker A, Neuerburg JM, Adam G, et al. Real-time MR guidance for inferior vena cava filter placement. J Vasc Interv Radiol. 2001; 12: 753–756.[Medline] [Order article via Infotrieve]
  6. Rasche V, de Boer RW, Holz D, et al. Continuous radial data acquisition for dynamic MRI. Magn Reson Med. 1995; 34: 754–761.[Medline] [Order article via Infotrieve]
  7. Riederer SJ, Tasciyan T, Farzaneh F, et al. MR fluoroscopy: technical feasibility. Magn Reson Med. 1988; 8: 1–15.[Medline] [Order article via Infotrieve]
  8. Buecker A, Spuentrup E, Grabitz R, et al. Real-time MR guidance for placement of a self-made fully MR-compatible atrial septal occluder: in vitro test. Rofo Fortschr Geb Rontgenstr Neuen Bildgeb Verfahr. 2002; 174: 283–285.[Medline] [Order article via Infotrieve]
  9. Berger F, Ewert P, Dahnert I, et al. Interventional occlusion of atrial septum defects larger than 20 mm in diameter [in German]. Z Kardiol. 2000; 89: 1119–1125.[CrossRef][Medline] [Order article via Infotrieve]
  10. Omary RA, Frayne R, Unal O, et al. MR-guided angioplasty of renal artery stenosis in a pig model: a feasibility study. J Vasc Interv Radiol. 2000; 11: 373–381.[Medline] [Order article via Infotrieve]
  11. Lardo AC, McVeigh ER, Jumrussirikul P, et al. Visualization and temporal/spatial characterization of cardiac radiofrequency ablation lesions using magnetic resonance imaging. Circulation. 2000; 102: 698–705.[Abstract/Free Full Text]
  12. Spuentrup E, Ruebben A, Schaeffter T, et al. MR-guided coronary stent placement in a pig model. Circulation. 2002; 105: 874–879.[Abstract/Free Full Text]
  13. Buecker A, Spuentrup E, Ruebben A, et al. Artifact-free in-stent lumen visualization by standard MR angiography using a new metallic MRI stent. Circulation. 2002; 105: 1772–1775.[Abstract/Free Full Text]
  14. Grebe O, Giesler M, Kestler HA, et al. Magnetic resonance imaging after percutaneous closure of a patent foramen ovale. Circulation. 2001; 104: E117–E118.[Medline] [Order article via Infotrieve]
  15. Godart F, Beregi JP, Nicol L, et al. MR-guided balloon angioplasty of stenosed aorta: in vivo evaluation using near-standard instruments and a passive tracking technique. J Magn Reson Imaging. 2000; 12: 639–644.[CrossRef][Medline] [Order article via Infotrieve]
  16. Konings MK, Bartels LW, Smits HF, et al. Heating around intravascular guidewires by resonating RF waves. J Magn Reson Imaging. 2000; 12: 79–85.[CrossRef][Medline] [Order article via Infotrieve]



This article has been cited by other articles:


Home page
CirculationHome page
D. S. Baim and R. Y. Kwong
Is Magnetic Resonance Image Guidance the Key to Opening Chronic Total Occlusions?
Circulation, February 28, 2006; 113(8): 1053 - 1055.
[Full Text] [PDF]


Home page
CirculationHome page
A. N. Raval, P. V. Karmarkar, M. A. Guttman, C. Ozturk, S. Sampath, R. DeSilva, R. J. Aviles, M. Xu, V. J. Wright, W. H. Schenke, et al.
Real-Time Magnetic Resonance Imaging-Guided Endovascular Recanalization of Chronic Total Arterial Occlusion in a Swine Model
Circulation, February 28, 2006; 113(8): 1101 - 1107.
[Abstract] [Full Text] [PDF]


Home page
CirculationHome page
R. J. Lederman
Cardiovascular Interventional Magnetic Resonance Imaging
Circulation, November 8, 2005; 112(19): 3009 - 3017.
[Full Text] [PDF]


Home page
CirculationHome page
A. N. Raval, J. D. Telep, M. A. Guttman, C. Ozturk, M. Jones, R. B. Thompson, V. J. Wright, W. H. Schenke, R. DeSilva, R. J. Aviles, et al.
Real-Time Magnetic Resonance Imaging-Guided Stenting of Aortic Coarctation With Commercially Available Catheter Devices in Swine
Circulation, August 2, 2005; 112(5): 699 - 706.
[Abstract] [Full Text] [PDF]


Home page
J Am Coll CardiolHome page
V. K. Raman, P. V. Karmarkar, M. A. Guttman, A. J. Dick, D. C. Peters, C. Ozturk, B. S.S. Pessanha, R. B. Thompson, A. N. Raval, R. DeSilva, et al.
Real-Time Magnetic Resonance-Guided Endovascular Repair of Experimental Abdominal Aortic Aneurysm in Swine
J. Am. Coll. Cardiol., June 21, 2005; 45(12): 2069 - 2077.
[Abstract] [Full Text] [PDF]


Home page
RadiologyHome page
G. A. Krombach, J. G. Pfeffer, S. Kinzel, M. Katoh, R. W. Gunther, and A. Buecker
MR-guided Percutaneous Intramyocardial Injection with an MR-compatible Catheter: Feasibility and Changes in T1 Values after Injection of Extracellular Contrast Medium in Pigs
Radiology, May 1, 2005; 235(2): 487 - 494.
[Abstract] [Full Text] [PDF]


Home page
HeartHome page
R Corti, J Badimon, G Mizsei, F Macaluso, M Lee, P Licato, J F Viles-Gonzalez, V Fuster, and W Sherman
Real time magnetic resonance guided endomyocardial local delivery
Heart, March 1, 2005; 91(3): 348 - 353.
[Abstract] [Full Text] [PDF]


Home page
HeartHome page
I M Barbash, J Leor, M S Feinberg, A Tessone, S Aboulafia-Etzion, A Orenstein, J Ruiz-Cabello, J S Cohen, and Y Mardor
Interventional magnetic resonance imaging for guiding gene and cell transfer in the heart
Heart, January 1, 2004; 90(1): 87 - 91.
[Abstract] [Full Text] [PDF]


Home page
CirculationHome page
A. J. Dick, M. A. Guttman, V. K. Raman, D. C. Peters, B. S.S. Pessanha, J. M. Hill, S. Smith, G. Scott, E. R. McVeigh, and R. J. Lederman
Magnetic Resonance Fluoroscopy Allows Targeted Delivery of Mesenchymal Stem Cells to Infarct Borders in Swine
Circulation, December 9, 2003; 108(23): 2899 - 2904.
[Abstract] [Full Text] [PDF]


Home page
CirculationHome page
S. Schalla, M. Saeed, C. B. Higgins, A. Martin, O. Weber, and P. Moore
Magnetic Resonance-Guided Cardiac Catheterization in a Swine Model of Atrial Septal Defect
Circulation, October 14, 2003; 108(15): 1865 - 1870.
[Abstract] [Full Text] [PDF]


Home page
Am. J. Respir. Crit. Care Med.Home page
P. Haage, W. Piroth, G. Krombach, S. Karaagac, T. Schaffter, R. W. Gunther, and A. Bucker
Pulmonary Embolism: Comparison of Angiography with Spiral Computed Tomography, Magnetic Resonance Angiography, and Real-Time Magnetic Resonance Imaging
Am. J. Respir. Crit. Care Med., March 1, 2003; 167(5): 729 - 734.
[Abstract] [Full Text] [PDF]


This Article
Right arrow Abstract Freely available
Right arrow Full Text (PDF)
Right arrow Data Supplement
Right arrow All Versions of this Article:
106/4/511    most recent
01.CIR.0000023621.88708.62v1
Right arrow Alert me when this article is cited
Right arrow Alert me if a correction is posted
Right arrow Citation Map
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Download to citation manager
Right arrow Request Permissions
Citing Articles
Right arrow Citing Articles via HighWire
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Buecker, A.
Right arrow Articles by Günther, R. W.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Buecker, A.
Right arrow Articles by Günther, R. W.
Right arrowPubmed/NCBI databases
Medline Plus Health Information
*MRI Scans
Related Collections
Right arrow Cardiac development
Right arrow Catheter-based coronary and valvular interventions: other