Donate Help Contact The AHA Sign In Home
American Heart Association
Circulation
Search: search_blue_button Advanced Search
Circulation. 2002;105:328-333
doi: 10.1161/hc0302.102598
This Article
Right arrow Abstract Freely available
Right arrow Full Text (PDF)
Right arrow Alert me when this article is cited
Right arrow Alert me if a correction is posted
Right arrow Citation Map
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Download to citation manager
Right arrowRequest Permissions
Citing Articles
Right arrow Citing Articles via HighWire
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Langerak, S. E.
Right arrow Articles by van der Wall, E. E.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Langerak, S. E.
Right arrow Articles by van der Wall, E. E.
Right arrowPubmed/NCBI databases
Medline Plus Health Information
*Coronary Artery Bypass Surgery
Related Collections
Right arrow Coronary imaging: angiography/ultrasound/Doppler/CC
Right arrow CT and MRI

(Circulation. 2002;105:328.)
© 2002 American Heart Association, Inc.


Clinical Investigation and Reports

Detection of Vein Graft Disease Using High-Resolution Magnetic Resonance Angiography

Susan E. Langerak, MSc; Hubert W. Vliegen, MD; Albert de Roos, MD; Aeilko H. Zwinderman, PhD; J. Wouter Jukema, MD; Patrik Kunz, PhD; Hildo J. Lamb, PhD; Ernst E. van der Wall, MD

From the Departments of Cardiology (S.E.L., H.W.V., J.W.J., E.E.V.D.W.), Radiology (S.E.L., A.D.R., P.K., H.J.L.), and Medical Statistics (A.H.Z.), Leiden University Medical Center, Leiden, the Netherlands; and Interuniversity Cardiology Institute of the Netherlands (S.E.L.), Utrecht, the Netherlands.

Correspondence to Prof Dr E.E. van der Wall, MD, Leiden University Medical Center, Department of Cardiology (C5-P), Albinusdreef 2, 2300 RC Leiden, PO Box 9600 2333 ZA, the Netherlands. E-mail E.E.van_der_Wall{at}LUMC.nl


*    Abstract
up arrowTop
*Abstract
down arrowIntroduction
down arrowMethods
down arrowResults
down arrowDiscussion
down arrowReferences
 
Background The application of previous magnetic resonance (MR) angiography techniques has enabled noninvasive differentiation between patent and occluded coronary artery bypass grafts. However, the detection of graft stenosis remains difficult. The purpose of our study was to determine the accuracy of high-resolution navigator-gated 3-dimensional (3-D) MR angiography in detecting vein graft disease.

Methods and Results MR angiography was performed in addition to coronary angiography with quantitative coronary analysis in 56 vein grafts from 38 patients (mean age 66.6±9.3 years), who presented with recurrent chest pain after bypass surgery. Eighteen grafts showed a luminal stenosis >=50%, 11 grafts a stenosis >=70%, and 6 grafts were occluded. All MR angiograms were evaluated independently by 2 blinded observers, who scored the presence of graft occlusion and graft stenosis >=50% and >=70% with a confidence level of 1 to 10. MR image quality was judged as insufficient in 6 grafts and these were excluded. Receiver-operator characteristic analysis revealed an area under the curve of 0.89 and 0.89 for identifying graft occlusion, 0.81 and 0.87 for stenosis >=50%, and 0.82 and 0.79 for stenosis >=70% for the 2 observers, respectively. Interobserver agreement in assessing graft occlusion and stenosis >=50% and >=70% was 94% ({kappa}=0.74, r=0.81), 72% ({kappa}=0.40, r=0.66), and 82% ({kappa}=0.53, r=0.72), respectively.

Conclusions High-resolution navigator-gated 3-D MR angiography allows not only good differentiation between patent and occluded vein grafts but also the assessment of vein graft disease with a fair diagnostic accuracy. This approach offers perspective as a noninvasive diagnostic tool for patients who present with recurrent chest pain after vein graft surgery.


Key Words: magnetic resonance imaging • stenosis • bypass • angiography


*    Introduction
up arrowTop
up arrowAbstract
*Introduction
down arrowMethods
down arrowResults
down arrowDiscussion
down arrowReferences
 
Coronary artery bypass graft surgery is a frequently performed revascularization procedure in patients with multivessel coronary artery disease. The clinical outcome after bypass surgery depends on the status of the grafts postoperatively. Initially most patients are free of angina, but patients may develop chest pain as a result of occlusion early after surgery or progression of atherosclerosis in the long term.1,2 Coronary angiography is the gold standard to evaluate the status of grafts, but this is an invasive procedure that includes x-ray exposure, requires hospitalization, and includes a (small) risk of complications.3 These disadvantages make the use of coronary angiography less attractive as diagnostic screening tool for bypass graft patients who present with postoperative angina. This implies the need for noninvasive alternative diagnostic methods.

Magnetic resonance (MR) imaging is a noninvasive alternative method that allows direct visualization of grafts. Previous 2-dimensional (2-D) spin-echo and gradient-echo MR techniques,46 3-dimensional (3-D) breath-hold contrast-enhanced MR angiography techniques,7,8 and volume coronary angiography using targeted scans (VCATS)9 have enabled the evaluation of graft patency and could only differentiate between graft patency and occlusion. The assessment of vein graft disease has remained a problem. MR angiography techniques with better spatial resolution and shorter image acquisition window have the potential to overcome these problems. Recently, a free-breathing 3-D MR angiography with T2-preparation prepulse and short acquisition window was developed that allowed reliable visualization of proximal and mid portions of the left and right coronary artery with submillimeter resolution.10,11 This MR angiography approach may fulfill the criteria to identify vein graft stenosis noninvasively and, therefore, is a potential diagnostic tool to identify those patients with postoperative angina resulting from progressive atherosclerotic vein graft disease.

The purpose of our study was to determine the value of this improved MR angiography technique (1) for differentiation between patent and occluded vein grafts, and (2) for assessment of vein graft disease in patients who present with recurrent chest pain after bypass surgery.


*    Methods
up arrowTop
up arrowAbstract
up arrowIntroduction
*Methods
down arrowResults
down arrowDiscussion
down arrowReferences
 
Patients
Fifty-six vein grafts from 38 patients (mean age 66.6±9.3 years, range 43 to 81 years) who were scheduled to undergo x-ray coronary angiography because of recurrent chest pain after bypass surgery (8.2±5.4 years, range 0 to 21 years) were studied. High-resolution MR angiography scans were performed in these patients as part of a MR cardiac function protocol in which adenosine stress testing was performed.

Patients with stents in the graft or near the distal graft anastomosis were excluded. MR-related exclusion criteria were unstable angina, the presence of a pacemaker, atrial fibrillation, claustrophobia, and the inability to lie flat. Exclusion criteria for the function protocol were chronic obstructive pulmonary disease, sick sinus syndrome, and second or third degree atrioventricular block.12,13 In 19 patients, MR angiography was performed before coronary angiography (mean time 2.7±2.2 days) and in the other 19 patients MR angiography was done after coronary angiography (mean time 9.4±13.7 days). No clinical events occurred between both examinations. All patients gave informed consent, and the medical ethical committee in our hospital approved the study protocol. Patient and graft characteristics are depicted in Table 1.


View this table:
[in this window]
[in a new window]
 
Table 1. Patient and Graft Characteristics

X-Ray Coronary Angiography
Vascular access was obtained using the femoral approach with the Seldinger technique and a 6- or 7-French catheter. To standardize vasomotor tone in the native coronary arteries beyond the graft anastomosis, grafts were visualized after injection of a 0.3-mg bolus nitroglycerine selectively into the graft. This was part of the standard operating procedure to quantify luminal stenosis severity in native coronary arteries by quantitative coronary analysis (QCA). Visualization was done according to standardized projections (a right-anterior-oblique and left-anterior-oblique projection >60° apart). Off-line computer-assisted QCA was performed by an independent corelab (Heart Core).14 According to QCA data, grafts were divided into 4 subgroups: patent grafts (0% to 99% luminal stenosis), grafts with >=50% luminal stenosis, grafts with >=70% luminal stenosis, and occluded grafts (100% luminal stenosis). The location of the graft stenosis was also scored as either in the graft origin or graft body.

MR Imaging
A 1.5 Tesla Gyroscan ACS-NT Philips MR scanner (Philips Medical Systems) with Powertrack 6000 gradients (25 mT/m, 100 mT/m/ms), cardiac research software patch (CPR 6), and 5-element cardiac synergy coil was used. One operator (S.E.L.) and a medical doctor for patient monitoring performed the MR examination. Because MRI was performed after x-ray coronary angiography in 19 patients, the operator was not blinded to angiographic results in these patients, although in most cases the exact diagnosis was not known. According to a previously described MR protocol to visualize native coronary arteries, 2 localizer scans were performed:10 (1) a multislice 2-D turbo-field-echo (TFE) survey scan to identify the right hemidiaphragm and rough cardiac structures, (2) followed by a transverse ECG-gated navigator-gated and corrected 3-D turbo-field echo-planar-imaging (TFEPI) scout to localize the vein grafts as they course from their origin to distally.15

High-Resolution MR Angiography
Three anatomical landmarks in the graft, namely the origin and most apical level of the graft and the mid-distance between these points, were manually selected, and the computer calculated the double-oblique plane that fits these 3 points. This plane was used to plan the ECG-gated navigator-gated and corrected 3-D high-resolution TFE MR angiography scan.10,11,16 The pulse sequence consisted of a T2-preparation prepulse for muscle suppression, a rest slab for foldover suppression, navigator gating and tracking for freezing of the respiratory motion, a fat suppression prepulse, and finally, the image acquisition. Data were acquired in mid-diastole and end-expiration with acquisition duration of 71 ms using a heart rate–dependent trigger delay. A low-high k-space-filling pattern was applied for data acquisition. The following scan parameters were used: repetition time of 7.1 ms, 10 {alpha}-pulses per shot, echo time of 1.9 ms, field-of-view of 360 mm, rectangular field-of-view of 75%, scan matrix of 512x512, scan percentage of 70%, and 20 overcontiguous slices of 3-mm thickness reconstructed to 1.5 mm, resulting in a spatial resolution of 0.7x1.00x1.5 mm.

MR Image Analysis
An experienced cardiologist and radiologist, who were blinded to the results of coronary angiography but informed about the surgical graft anastomosis, independently evaluated all MR angiograms. Image evaluation was performed on an Easy Vision Workstation (Philips Medical Systems) by analyzing the original slices of the 3-D data set and the multiplanar-reformat image (MPR). Using this postprocessing technique, the user navigates through the 3-D stack and interactively marks the graft along its course. MPR reconstructions were made without knowledge of angiographic results. Both observers preferred the use of source data as compared with the MPR image because the MPR image is a nonanatomical plane and dependent on knowledge of the individual who performs postprocessing.

Each observer judged for each MR angiogram the image quality: (1) blurring or major artifacts with poor vessel conspicuity, which is insufficient for diagnosis of graft stenosis; (2) minor blurring or artifacts and sufficient for diagnosis of graft stenosis without excellent graft visualization; and (3) excellent image quality with no blurring or artifacts and a high degree of vessel conspicuity. When image quality was scored as insufficient (score 1), the MR angiogram was excluded from further analysis by that observer. In the remaining angiograms for each observer, the presence of graft occlusion (100% luminal stenosis), >=50% luminal stenosis, and >=70% luminal stenosis was scored as present or not with a confidence level from 1 to 10 for subsequent receiver-operator characteristic (ROC) analysis. A score of 1 denotes 100% certainty of graft occlusion and a score of 10 refers to 100% certainty of graft patency. A similar scoring system was used for evaluation of graft stenosis >=50% and graft stenosis >=70%, in which a score of 1 denotes a 100% certainty of presence of a stenosis and a score of 10 refers to a 100% certainty that there is no graft stenosis present. To distinguish a diseased from nondiseased graft, the observer estimated the change in luminal diameter before and within the signal void. In addition, the location of the graft stenosis on the MR angiogram was scored by each observer as either in the graft origin or graft body.

Statistical Analysis
To determine the diagnostic accuracy of MR angiography in identification of vein graft occlusion and disease, visual interpretations of all MR angiograms were compared with QCA data. Diagnostic properties of MR angiography were evaluated by ROC-analysis, in which the sensitivity is plotted against the complement of specificity for each specific cut-off value in confidence level. The optimal cut-off value for determination of sensitivity and specificity was chosen according to standard practice.17 In order to account for association between grafts within the same patient, robust variances were calculated.18 The interobserver agreement was determined by Cohen’s {kappa} statistic and correlation coefficient (r).


*    Results
up arrowTop
up arrowAbstract
up arrowIntroduction
up arrowMethods
*Results
down arrowDiscussion
down arrowReferences
 
Image quality was judged as insufficient by one observer in 6 out of 56 MR angiograms and these 6 grafts were excluded from further statistical analysis of the data from this observer. The excluded grafts were patent by QCA and one graft had a moderate stenosis between 50% to 70%. Statistical analysis of the visual scores from the other observer was performed in all 56 grafts and in the remaining 50 grafts.

The results of x-ray coronary angiography with QCA are shown in Table 1. Figures 1, 2, and 3 depict a MR angiogram with the accompanying x-ray coronary angiography of a normal vein graft, a patent vein graft with a moderate stenosis, and an occluded graft, respectively. . .



View larger version (74K):
[in this window]
[in a new window]
 
Figure 1. MR angiogram and corresponding coronary angiogram (A, 48° left-anterior-oblique view) of a normal vein graft to the obtuse marginal branch of the left circumflex coronary artery. B1–7, Selection of individual slices of the MR angiogram in the oblique coronal plane. Multiplanar-reconstruction (MPR) of the 3-D scan revealed the MPR image in which the graft is visualized in a single plane (C). LV indicates left ventricle; Ao, ascending aorta; and PA, pulmonary artery.



View larger version (63K):
[in this window]
[in a new window]
 
Figure 2. A, Coronary angiogram (52° left-anterior-oblique view) of a vein graft to the left anterior descending coronary artery with a 56% proximal stenosis (*) as determined by QCA. MR angiography also shows this moderate stenosis as can be seen in selected individual slices (B2–8) and the MPR image (C). At the level of the stenosis, one can see the change in graft lumen diameter (tapering graft contour). The graft origin falls just outside the 3-D scan volume as can be seen in image B2. However, the localizer scan (B1) shows the origin clearly. Ao indicates ascending aorta; PA, pulmonary artery; and SCV, superior caval vein.



View larger version (59K):
[in this window]
[in a new window]
 
Figure 3. MR angiography demonstrates an occluded graft to the posterolateral branch of the left circumflex coronary artery. The proximal occlusion can be seen by scrolling trough the individual slices (B1–6) and after postprocessing techniques in the MPR image (C). This was confirmed by coronary angiography (A, 23° right-anterior-oblique view). *Occlusion. Ao indicates ascending aorta; PA, pulmonary artery; LA, left atrium; and RA, right atrium.

ROC analysis of the first observers’ interpretations revealed an area under the curve (AUC) of 0.89 for detecting graft occlusion, 0.81 for detecting graft stenosis >=50%, and 0.82 for detecting graft stenosis >=70%. Including the 6 grafts that were judged as insufficient by the second observer in the analysis resulted in values of 0.88, 0.80, and 0.80, respectively. The interpretations from the second observer for the 50 grafts revealed AUCs of 0.89 for detecting occluded grafts, 0.87 for detecting graft stenosis >=50%, and 0.79 for detecting graft stenosis >=70% (Figure 4). Sensitivity and specificity for identifying graft occlusion, graft stenosis >=50%, and graft stenosis >=70% were 83/98%, 65/82%, and 73/87%, respectively, for the first observer (Table 2). For the second observer, the equivalent numbers were 83/100%, 82/88%, and 73/80%, respectively. The interobserver agreement was 94% ({kappa}=0.74, r=0.81) for assessment of graft patency, 72% ({kappa}=0.40, r=0.66) for detection of graft stenosis >=50%, and 82% ({kappa}=0.53, r=0.72) for detection of graft stenosis >=70%.



View larger version (13K):
[in this window]
[in a new window]
 
Figure 4. Receiver-operator characteristic (ROC) analysis was performed for the observers’ interpretation of graft occlusion and >=50% and >=70% luminal stenosis. The normal and dotted line represent the ROC curves for the first and second observer, respectively. The arrows indicate the optimal cut-off points for the first ({blacklozenge}) and second observer (*).


View this table:
[in this window]
[in a new window]
 
Table 2. Diagnostic Accuracy of High-Resolution MR Angiography in Identifying Graft Occlusion and Graft Stenosis >=50% and >=70%

In all grafts that were correctly scored as having a stenosis >=50% by the first observer, the location of the stenosis as scored on the MR angiogram corresponded to the location by QCA. In one graft that was correctly scored as having a stenosis >=50% by the second observer, the location of the stenosis as scored on the MR angiogram did not correspond to the location by QCA. In this graft, a 74% stenosis in the origin was missed, and a stenosis >=70% in the graft body was incorrectly observed.

The duration of a MR angiography study in a patient with 2 vein grafts was approximately 1 hour, depending on the gating efficiency. Total MR examination includes patient preparation (10 minutes), planning and scanning of 2 localizer scans (10 minutes), and the high-resolution scan (15 to 20 minutes per graft). The feasible maximum duration of a MR imaging study from our experience is 1.5 hours. This implies that from a practical perspective the application of high-resolution MR angiography, by using the present MR technology, is limited to patients with a maximum of 4 vein grafts.


*    Discussion
up arrowTop
up arrowAbstract
up arrowIntroduction
up arrowMethods
up arrowResults
*Discussion
down arrowReferences
 
Our findings confirm previous observations that MR angiography allows differentiation between patent and occluded vein grafts. The novel finding in the current study is that high-resolution MR angiography enables the assessment of vein graft stenosis severity with a fair diagnostic accuracy. To the best of our knowledge, this is the first study that addresses the value of MR angiography in assessing the severity of vein graft stenosis. High-resolution MR angiography offers perspective as a noninvasive diagnostic screening tool for patients who present with recurrent chest pain after bypass surgery.

Previous Experience in MR Angiography of Grafts
The first pioneers in the field of graft MR angiography used nonrespiratory-compensated, ECG-triggered, 2-D spin-echo,46 and gradient-echo techniques,6,19,20 and later on, breath-hold 2-D gradient-echo sequences with k-space segmentation were applied.21 When 2 successive proximal slices showed a patent vessel, it was concluded that the graft was patent. More recently, 3-D MR angiography techniques, such as gadolinium-enhanced breath-hold MR angiography sequence and navigator-gated MR angiography with 1-mm resolution, proved to be feasible in assessing graft patency over a longer course.7,8,22 The overall sensitivity and specificity of these techniques in detecting patent grafts varied from 88% to 98% and 72% to 100%, respectively. In the present study, we applied a technically improved high-resolution MR angiography sequence, which allowed the identification of vein graft occlusion with an at least as good sensitivity (83%) and specificity (98% to 100%) as previously obtained values with lower spatial resolution.48,1922 The fact that our method has not much better diagnostic performance than the cruder approaches might be attributable to a difference in pretest probability of disease, patient selection, and inclusion criteria. For instance, the prevalence of graft occlusion in the older studies varied from 19% to 48%, which was considerably higher than the occlusion prevalence (11%) in the present study.

Despite the increased possibilities of earlier MR angiography studies to differentiate between patent and occluded grafts, even more distally in grafts, the detection of significant graft stenosis has remained difficult due to limitations in spatial resolution. In the present study, we first demonstrate the diagnostic properties of high-resolution 3-D MR angiography10,11 in detecting vein graft stenosis severity.

Study Limitations
The present study focused solely on vein grafts, because vascular clips that surround arterial grafts disturb the magnetic field homogeneity and demonstrate major artifacts. These artifacts prevent good visualization of arterial grafts with MR angiography and do not allow assessment of arterial graft patency at that level. Similarly, the visualization of the stent lumen has been jeopardized by artifacts. However, MR flow mapping can be performed in internal mammary artery grafts and stented vein grafts by selecting a scan plane either in between the vascular clips or proximal or distal from the stent.

Signal voids resulting from artifacts caused by vascular clips or stents can be differentiated from stenotic grafts because these artifacts extend outside the lumen. A pitfall in interpretation of 3-D angiographic data are that the vessel of interest courses out of the image volume, mimicking an occlusion and resulting in false-positive findings for graft occlusion. Therefore, a prerequisite for the diagnosis graft occlusion is that the last slice, in which the graft can be seen, is not at the border of the 3-D volume.

The image duration of the navigator-gated MR angiography scan is rather long compared with a breath-hold sequence. This limits the use of this sequence in a more comprehensive MR study that might include the assessment of left ventricular wall motion and perfusion at baseline and during pharmacological stress.

Nitroglycerine was given prior to x-ray coronary angiography to standardize vasomotor tone in the native vessels beyond the graft anastomosis for QCA. Because variations in vein graft lumen and vein graft spasms are a rarity postoperatively23 and the present study focused solely on grafts, no nitroglycerine was given prior to MR angiography. If small variations in graft lumen would occur over time, these would probably not affect the visual scoring of grafts.

Future Perspectives
In the present study, we focused on diagnostic properties of high-resolution MR angiography in detecting graft stenosis severity. To study the accuracy of this diagnostic tool in evaluating the status of coronary arteries in and beyond the distal graft anastomosis, additional MR angiography scans are required with optimal scan planning for the native right and left coronary artery. MR flow mapping6,2426 in combination with MR angiography may be an alternative tool to study distal coronary arteries because baseline and stress flow in the proximal part of the graft is a functional measure of the entire vascular bed beyond the level of the flow measurement. Moreover, invasive studies have shown that lesion morphology does not necessarily reflect the functional graft status. Therefore, a combined approach of MR angiography and flow mapping may further improve the results.

Intravascular contrast agents have been successfully applied in coronary MR angiography, leading to a considerable enhancement of the blood/muscle contrast compared with T2-preparation techniques27 and low-molecular Gadolinium compounds.28 Phase-2 clinical trials with these promising agents are currently in progress to examine the effect of intravascular contrast agents in the diagnostic performance of MR angiography in stenosis detection.

Conclusion
Our findings confirm previous observations that high-resolution MR angiography allows differentiation between patent and occluded vein grafts. However, the novel finding in the present study is that high-resolution MR angiography enables the assessment of vein graft stenosis severity with a fair diagnostic accuracy. This offers perspective for noninvasive screening of patients who present with recurrent chest pain after bypass surgery.


*    Acknowledgments
 
S.E. Langerak is supported by a grant from the Netherlands Heart Foundation (97.173).

Received September 5, 2001; revision received November 7, 2001; accepted November 8, 2001.


*    References
up arrowTop
up arrowAbstract
up arrowIntroduction
up arrowMethods
up arrowResults
up arrowDiscussion
*References
 
1. Campeau L, Enjalbert M, Lesperance J, et al. Atherosclerosis and late closure of aortocoronary saphenous vein grafts: sequential angiographic studies at 2 weeks, 1 year, 5 to 7 years, and 10 to 12 years after surgery. Circulation. 1983; 68: II1–7.

2. Bourassa MG, Fisher LD, Campeau L, et al. Long-term fate of bypass grafts: the Coronary Artery Surgery Study (CASS) and Montreal Heart Institute experiences. Circulation. 1985; 72: V71–V78.

3. Johnson LW, Krone R. Cardiac catheterization 1991: a report of the Registry of the Society for Cardiac Angiography and Interventions (SCA&I). Cathet Cardiovasc Diagn. 1993; 28: 219–220.[Medline] [Order article via Infotrieve]

4. White RD, Caputo GR, Mark AS, et al. Coronary artery bypass graft patency: noninvasive evaluation with MR imaging. Radiology. 1987; 164: 681–686.[Abstract/Free Full Text]

5. Rubinstein RI, Askenase AD, Thickman D, et al. Magnetic resonance imaging to evaluate patency of aortocoronary bypass grafts. Circulation. 1987; 76: 786–791.[Abstract/Free Full Text]

6. Galjee MA, van Rossum AC, Doesburg T, et al. Value of magnetic resonance imaging in assessing patency and function of coronary artery bypass grafts: an angiographically controlled study. Circulation. 1996; 93: 660–666.[Abstract/Free Full Text]

7. Wintersperger BJ, Engelmann MG, von Smekal A, et al. Patency of coronary bypass grafts: assessment with breath-hold contrast-enhanced MR angiography–value of a non-electrocardiographically triggered technique. Radiology. 1998; 208: 345–351.[Abstract/Free Full Text]

8. Vrachliotis TG, Bis KG, Aliabadi D, et al. Contrast-enhanced breath-hold MR angiography for evaluating patency of coronary artery bypass grafts. AJR Am J Roentgenol. 1997; 168: 1073–1080.[Abstract/Free Full Text]

9. Wielopolski PA, van Geuns RJ, de Feyter PJ, et al. Coronary arteries. Eur Radiol. 2000; 10: 12–35.[CrossRef][Medline] [Order article via Infotrieve]

10. Stuber M, Botnar RM, Danias PG, et al. Double-oblique free-breathing high resolution three-dimensional coronary magnetic resonance angiography. J Am Coll Cardiol. 1999; 34: 524–531.[Abstract/Free Full Text]

11. Botnar RM, Stuber M, Danias PG, et al. Improved coronary artery definition with T2-weighted, free-breathing, three-dimensional coronary MRA. Circulation. 1999; 99: 3139–3148.[Abstract/Free Full Text]

12. Prvulovich E. Resuscitation following arrhythmia in patients undergoing pharmacological/exercise stress for myocardial perfusion imaging. Nucl Med Commun. 1996; 17: 1003–1005.[Medline] [Order article via Infotrieve]

13. Pennell DJ. Pharmacological cardiac stress: when and how? Nucl Med Commun. 1994; 15: 578–585.[Medline] [Order article via Infotrieve]

14. Reiber JH, van der Zwet PM, Koning G, et al. Accuracy and precision of quantitative digital coronary arteriography: observer-, short-, and medium-term variabilities. Cathet. Cardiovasc Diagn. 1993; 28: 187–198.

15. Langerak SE, Kunz P, de Roos A, et al. Evaluation of coronary artery bypass grafts by magnetic resonance imaging. J Magn Reson Imaging. 1999; 10: 434–441.[CrossRef][Medline] [Order article via Infotrieve]

16. Stuber M, Botnar RM, Danias PG, et al. Submillimeter three-dimensional coronary MR angiography with real-time navigator correction: comparison of navigator locations. Radiology. 1999; 212: 579–587.[Abstract/Free Full Text]

17. van Erkel AR, Pattynama PM. Receiver operating characteristic (ROC) analysis: basic principles and applications in radiology. Eur J Radiol. 1998; 27: 88–94.[CrossRef][Medline] [Order article via Infotrieve]

18. Zeger SL, Liang KY. An overview of methods for the analysis of longitudinal data. Stat Med. 1992; 11: 1825–1839.[Medline] [Order article via Infotrieve]

19. White RD, Pflugfelder PW, Lipton MJ, et al. Coronary artery bypass grafts: evaluation of patency with cine MR imaging. AJR Am J Roentgenol. 1988; 150: 1271–1274.[Abstract/Free Full Text]

20. Aurigemma GP, Reichek N, Axel L, et al. Noninvasive determination of coronary artery bypass graft patency by cine magnetic resonance imaging. Circulation. 1989; 80: 1595–1602.[Abstract/Free Full Text]

21. von Smekal A, Knez A, Seelos KC, et al. [A comparison of ultrafast computed tomography, magnetic resonance angiography and selective angiography for the detection of coronary bypass patency]. Rofo Fortschr Geb Rontgenstr Neuen Bildgeb Verfahr. 1997; 166: 185–191.[Medline] [Order article via Infotrieve]

22. Kessler W, Achenbach S, Moshage W, et al. Usefulness of respiratory gated magnetic resonance coronary angiography in assessing narrowings > or =50% in diameter in native coronary arteries and in aortocoronary bypass conduits. Am J Cardiol. 1997; 80: 989–993.[CrossRef][Medline] [Order article via Infotrieve]

23. Webb JG, Aldridge HE, Fulop J, et al. Aortocoronary saphenous vein graft spasm inducing ventricular fibrillation. Am Heart J. 1989; 117: 485–486.[CrossRef][Medline] [Order article via Infotrieve]

24. Sakuma H, Globits S, O’Sullivan M, et al. Breath-hold MR measurements of blood flow velocity in internal mammary arteries and coronary artery bypass grafts. J Magn Reson Imaging. 1996; 6: 219–222.[Medline] [Order article via Infotrieve]

25. Debatin JF, Strong JA, Sostman HD, et al. MR characterization of blood flow in native and grafted internal mammary arteries. J Magn Reson Imaging. 1993; 3: 443–450.[Medline] [Order article via Infotrieve]

26. Langerak SE, Kunz P, Vliegen HW, et al. Improved MR flow mapping in coronary artery bypass grafts during adenosine-induced stress. Radiology. 2001; 218: 540–547.[Abstract/Free Full Text]

27. Stuber M, Botnar RM, Danias PG, et al. Contrast agent-enhanced, free-breathing, three-dimensional coronary magnetic resonance angiography. J Magn Reson Imaging. 1999; 10: 790–799.[CrossRef][Medline] [Order article via Infotrieve]

28. Taupitz M, Schnorr J, Wagner S, et al. Coronary magnetic resonance angiography: experimental evaluation of the new rapid clearance blood pool contrast medium P792. Magn Reson Med. 2001; 46: 932–938.[CrossRef][Medline] [Order article via Infotrieve]




This article has been cited by other articles:


Home page
Br. J. Radiol.Home page
N I Stauder, B Klumpp, H Stauder, G Blumenstock, M Fenchel, A Kuttner, C D Claussen, and S Miller
Assessment of coronary artery bypass grafts by magnetic resonance imaging
Br. J. Radiol., December 1, 2007; 80(960): 975 - 983.
[Abstract] [Full Text] [PDF]


Home page
Eur Heart JHome page
P. Malagutti, K. Nieman, W. B. Meijboom, C. A.G. van Mieghem, F. Pugliese, F. Cademartiri, N. R. Mollet, E. Boersma, P. P. de Jaegere, and P. J. de Feyter
Use of 64-slice CT in symptomatic patients after coronary bypass surgery: evaluation of grafts and coronary arteries
Eur. Heart J., August 1, 2007; 28(15): 1879 - 1885.
[Abstract] [Full Text] [PDF]


Home page
Eur. J. Cardiothorac. Surg.Home page
T. Wittlinger, O. Dzemali, I. Martinovic, and A. Moritz
Assessment of coronary artery bypass grafts patency with different magnetic resonance technologies.
Eur. J. Cardiothorac. Surg., September 1, 2006; 30(3): 436 - 442.
[Abstract] [Full Text] [PDF]


Home page
J Am Coll CardiolHome page
V. Fuster, Z. A. Fayad, P. R. Moreno, M. Poon, R. Corti, and J. J. Badimon
Atherothrombosis and High-Risk Plaque: Part II: Approaches by Noninvasive Computed Tomographic/Magnetic Resonance Imaging
J. Am. Coll. Cardiol., October 4, 2005; 46(7): 1209 - 1218.
[Abstract] [Full Text] [PDF]


Home page
J. Thorac. Cardiovasc. Surg.Home page
J. Karski, G. Djaiani, J. Carroll, M. Iwanochko, P. Seneviratne, P. Liu, W. Kucharczyk, L. Fedorko, T. David, and D. Cheng
Tranexamic acid and early saphenous vein graft patency in conventional coronary artery bypass graft surgery: A prospective randomized controlled clinical trial
J. Thorac. Cardiovasc. Surg., August 1, 2005; 130(2): 309 - 314.
[Abstract] [Full Text] [PDF]


Home page
Br. J. Radiol.Home page
N I Stauder, A M Scheule, U Hahn, M Fenchel, F S Eckstein, U Kramer, C D Claussen, and S Miller
Perioperative monitoring of flow and patency in native and grafted internal mammary arteries using a combined MR protocol
Br. J. Radiol., April 1, 2005; 78(928): 292 - 298.
[Abstract] [Full Text] [PDF]


Home page
J. Thorac. Cardiovasc. Surg.Home page
N. I. Stauder, M. Fenchel, H. Stauder, A. Kuttner, A. M. Scheule, U. Kramer, C. D. Claussen, and S. Miller
Assessment of minimally invasive direct coronary artery bypass grafting of the left internal thoracic artery by means of magnetic resonance imaging
J. Thorac. Cardiovasc. Surg., March 1, 2005; 129(3): 607 - 614.
[Abstract] [Full Text] [PDF]


Home page
J. Thorac. Cardiovasc. Surg.Home page
R. Marano, M. L. Storto, N. Maddestra, and L. Bonomo
Could multidetector computed tomography play a role in the management of patients readmitted with recurrent chest pain after surgical coronary revascularization?
J. Thorac. Cardiovasc. Surg., March 1, 2005; 129(3): 686 - 687.
[Full Text] [PDF]


Home page
Eur Heart JHome page
D. J. Pennell, U. P. Sechtem, C. B. Higgins, W. J. Manning, G. M. Pohost, F. E. Rademakers, A. C. van Rossum, L. J. Shaw, and E. K. Yucel
Clinical indications for cardiovascular magnetic resonance (CMR): Consensus Panel report
Eur. Heart J., November 1, 2004; 25(21): 1940 - 1965.
[Full Text] [PDF]


Home page
RadiologyHome page
J. K. Willmann, D. Weishaupt, R. Kobza, F. R. Verdun, B. Seifert, B. Marincek, and T. Boehm
Coronary Artery Bypass Grafts: ECG-gated Multi-Detector Row CT Angiography--Influence of Image Reconstruction Interval on Graft Visibility
Radiology, August 1, 2004; 232(2): 568 - 577.
[Abstract] [Full Text] [PDF]


Home page
Ann. Thorac. Surg.Home page
M. Dewey, A. Lembcke, C. Enzweiler, B. Hamm, and P. Rogalla
Isotropic half-millimeter angiography of coronary artery bypass grafts with 16-slice computed tomography
Ann. Thorac. Surg., March 1, 2004; 77(3): 800 - 804.
[Abstract] [Full Text] [PDF]


Home page
CirculationHome page
S. E. Langerak, H. W. Vliegen, J. W. Jukema, P. Kunz, A. H. Zwinderman, H. J. Lamb, E. E. van der Wall, and A. de Roos
Value of Magnetic Resonance Imaging for the Noninvasive Detection of Stenosis in Coronary Artery Bypass Grafts and Recipient Coronary Arteries
Circulation, March 25, 2003; 107(11): 1502 - 1508.
[Abstract] [Full Text] [PDF]


Home page
J Am Coll CardiolHome page
W. L. F. Bedaux, M. B. M. Hofman, S. L. A. Vyt, J. G. F. Bronzwaer, C. A. Visser, and A. C. van Rossum
Assessment of coronary artery bypass graft disease using cardiovascular magnetic resonance determination of flow reserve
J. Am. Coll. Cardiol., November 20, 2002; 40(10): 1848 - 1855.
[Abstract] [Full Text] [PDF]


This Article
Right arrow Abstract Freely available
Right arrow Full Text (PDF)
Right arrow Alert me when this article is cited
Right arrow Alert me if a correction is posted
Right arrow Citation Map
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Download to citation manager
Right arrowRequest Permissions
Citing Articles
Right arrow Citing Articles via HighWire
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Langerak, S. E.
Right arrow Articles by van der Wall, E. E.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Langerak, S. E.
Right arrow Articles by van der Wall, E. E.
Right arrowPubmed/NCBI databases
Medline Plus Health Information
*Coronary Artery Bypass Surgery
Related Collections
Right arrow Coronary imaging: angiography/ultrasound/Doppler/CC
Right arrow CT and MRI