(Circulation. 2001;104:2029.)
© 2001 American Heart Association, Inc.
Clinical Investigation and Reports |
From the Department of Medicine, Montreal Heart Institute (SD, L.B., J.L., F.H.), Montreal, Quebec, Canada; Department of Cardiology, Leiden University Medical Centre (M.J.S.), Leiden, The Netherlands; Ziekenhuis Oost Limburg (M.V.), Genk, Belgium; Royal Jubilee Hospital (D.H.), Victoria, Canada; Catholic University of Louvain-UCL-Mont-Godinne Hospital (P.C.), Mont-Godinne, Belgium; Cardiovascular Centre (B.d.B.), Aalst, Belgium; Chulalongkorn University (W.U.), Bangkok, Thailand; Escorts Heart Institute and Research Centre (A.S.), New Delhi, India; and Heart Core BV (J.H.C.R.), Leiden, The Netherlands.
Correspondence to Serge Doucet, 5000 Belanger St East, Montreal, Quebec, H1T 1C8, Canada. E-mail serge.doucet{at}sympatico.ca
| Abstract |
|---|
|
|
|---|
Methods and Results We randomly assigned 351 symptomatic patients needing dilatation of 1 native coronary vessel between 2.3 and 2.9 mm in size to angioplasty alone (n=182) or stent implantation (n=169). The primary end point was angiographic restenosis at 6 months. Secondary end points included death, myocardial infarction, bypass surgery, and target vessel revascularization in hospital and at 6 months. There were no significant differences between groups in terms of major in-hospital complications. There was a trend toward fewer in-hospital events in the stent group (3% versus 7.1% in angioplasty group, P=0.076). Crossovers to stent occurred in 37 patients (20.3%). Repeat angiography at 6-month follow-up was performed in 85.3% of patients. Angiographic restenosis occurred in 28% of the stent group and 32.9% of the angioplasty group (P=0.36). Target vessel revascularization was required in 17.8% versus 20.3% of patients (P=0.54), respectively.
Conclusions Stenting and standard coronary angioplasty are associated with equal restenosis rate in small coronary arteries. With a lower in-hospital complication rate, stenting may be a superior strategy in small vessels.
Key Words: angioplasty stents restenosis
| Introduction |
|---|
|
|
|---|
Small coronary arteries represent a fair amount of the day-to-day angioplasty practice. Depending on definition, prevalence ranges from 35%9 to 67%.10 Lesions in vessels with small reference diameters represent a distinct group with respect to clinical and morphological characteristics.9 This translates into lower primary angioplasty success and more frequent major adverse cardiac events.9 An inverse relationship has been found between vessel size and angiographic restenosis rate.10 Stenting could therefore be of great help in patients with lesions in small vessels. Retrospective and observational studies have been reported on stenting and small coronary arteries.1117 Very recently, 2 randomized studies comparing stent and angioplasty alone were published.18,19 Safety and early efficacy were documented, but because of conflicting results, the antirestenotic potential remains to be confirmed. We therefore designed a multicenter randomized trial to test the hypothesis that routine implantation of a stent, compared with balloon angioplasty alone, would be associated with reduced angiographic restenosis at 6 months in small coronary arteries.
| Methods |
|---|
|
|
|---|
2.3 mm and
2.9 mm by online quantitative coronary angiography (QCA). The lesion length had to be
12 mm without thrombus. Patients with left ventricular ejection fraction <40% or unable to take aspirin or ticlopidine were excluded. After giving written informed consent, patients were randomly stratified according to center with a block design and assigned to either angioplasty or stent placement.
Protocols
Angioplasty was performed in the conventional manner by femoral or radial approach, according to standard techniques at each center. Aspirin was prescribed and 10 000 IU of heparin was given before the procedure. A goal of <30% residual stenosis was set. Crossover to stent implantation was allowed in case of abrupt or threatened closure, defined as a dissection type C to F (NHLBI classification), TIMI flow <3, or
50% residual stenosis with myocardial ischemia. The stents were 15 mm premounted beStent Artist, available in 2.5-mm and 3-mm diameters (Medtronic Vascular). Unmounted beStents 8 mm and 25 mm were also available for very short lesions or to cover a long dissection postangioplasty. Stent implantation was performed after angioplasty according to routine clinical practice. Stents were selected with online QCA to achieve a balloon-to-artery ratio of 1.1. Final inflation pressure recommendation was 12 to 14 atmospheres. All patients received aspirin, 100 to 325 mg daily, after the procedure and ticlopidine, 250 to 500 mg daily for 1 month, if a stent was implanted. Platelet glycoprotein IIb/IIIa receptor inhibitors were discouraged but allowed if necessary.
Quantitative Coronary Angiography
Angiography was performed preintervention, postintervention, and at 6-month follow-up or earlier if needed. QCA was performed at the QCA laboratory of the Montreal Heart Institute for Canadian centers and at Heart Core BV for other centers. The QCA-CMS system20 (MEDIS medical imaging system) was used in both laboratories after standardizing and validating intercore laboratory variability.21 Offline QCA measurements were made in a single projection, showing the most severe stenosis. Whenever possible the same projection was used in all 3 angiograms. Each angiographic sequence was preceded by intracoronary injection of nitroglycerin. Minimal lumen diameter was measured, and percentage diameter-stenosis was calculated using the interpolated reference diameter approach. Standard morphological criteria were used to characterize the complexity of baseline lesions.22
End Points
The primary end point was angiographic restenosis, defined as a percentage diameter stenosis of
50% at follow-up. Secondary end points included the following: (1) angiographic success (reduction in stenosis to <50%, QCA); (2) procedural success (<50% diameter stenosis with assigned devices alone or with adjunctive devices) by visual assessment; (3) clinical success (angiographic success without clinical events, including death, myocardial infarction, bypass surgery, and revascularization of the target vessel during the hospital stay); (4) target vessel revascularization at 6 months; (5) absolute minimal lumen diameter after procedure and at follow-up; and (6) Canadian Cardiovascular Society functional class, medication, and repeat revascularization at 1 year.
All deaths were considered cardiac unless an unequivocal noncardiac cause could be established. Myocardial infarction was defined by new Q-waves >0.04 second or elevation of the serum creatine kinase to greater than twice the upper limit of normal with an elevated MB fraction (measured at 12 and 24 hours). Target vessel revascularization required recurrent angina or signs of ischemia.
Statistical Analysis
On the basis of the only preliminary data available on small arteries at the time of study design (published subsequently),11 the sample size required to demonstrate a restenosis-rate reduction from 52% to 35% or from 43% to 25% by a 2-sided test with an
error of 0.05 and a power of 0.90 was 275 and 234 patients, respectively. This 35% reduction of restenosis rate by stenting was considered clinically significant. To compensate for unsuccessful interventions, crossovers, and losses to follow-up, the sample size was increased by 25% to 350 patients. The results are expressed as mean±SD. Comparisons between treatment groups were performed on an intent-to-treat basis. Unpaired Student's t tests were used to assess differences in continuous variables. Categorical data, presented as rates, were compared by
2 test or Fishers exact test. Two-tailed probability values were calculated, with P<0.05 considered to indicate statistical significance.
| Results |
|---|
|
|
|---|
|
Procedural and Early Outcome
Of the 169 patients assigned to stenting, 166 (98.2%) had procedural success. In 2 patients, the wire failed to cross the lesion, and 1 patient required emergency coronary artery bypass surgery for type D dissection after predilatation. Of the 182 angioplasty-only patients, 179 (98.3%) had procedural success. In 1 patient, the wire failed to cross the lesion, 1 patient required emergency coronary artery bypass surgery, and 1 patient had a total occlusion and was treated medically. In the stent group, 4 patients (2.4%) were switched to angioplasty because of inability to cross the lesion with the stent. In the angioplasty group, 37 patients (20.3%) crossed over to stent implantation as a bailout procedure.
Procedural and in-hospital outcomes are shown in Table 2. Angiographic success was achieved in 98.2% of stent patients and 93.9% of angioplasty-only patients (P=0.0065). Clinical success was also greater in the stent group than the angioplasty group (95.3% versus 87.9%, respectively, P=0.0066). There were no significant differences in major in-hospital cardiac complications. There was a trend toward fewer nonQwave myocardial infarctions in the stent group (1.8% versus 4.9% in the angioplasty group, P=0.142) and fewer repeated angioplasties (0.6% versus 2.7%, respectively, P=0.217). There was a trend toward fewer occurrences of in-hospital events in the stent group (3% versus 7.1% in the angioplasty group, P=0.076).
|
Angiographic Results
Coronary angiography was repeated 6±2 (mean±SD) months after initial procedure in 289 of 339 (85.3%) patients eligible for angiographic follow-up. Angiography was not repeated or angiograms could not be analyzed in 23 patients in the stent group because of refusal (20 patients), technical problems in quantification (2), or death (1). In the angioplasty group, 30 patients refused follow-up angiography, 2 were unsuitable for quantification, and 1 died. Quantitative angiographic results are shown in Table 3. Immediately after intervention, a larger gain in luminal diameter was achieved in stented patients (1.37±0.42 versus 0.91±0.46 mm, P<0.0001), whereas the late loss in luminal diameter was higher after stenting (0.89±0.52 versus 0.48±0.60 mm, P<0.0001). The net gain at follow-up was thus not significantly different (0.51±0.55 versus 0.43±0.54 mm for stent versus balloon, P=0.28). The minimal lumen diameter at 6 months was 1.44±0.53 in the stent group and 1.37±0.57 mm in the angioplasty group (P=0.34). Cumulative frequency distributions of minimal lumen diameter are shown in Figure.
|
|
When results were analyzed according to intention-to-treat principles, restenosis occurred in 28% of stented patients and in 32.9% of patients in the angioplasty-only group (P=0.36). To assess results on the basis of actual treatment received, patients who crossed over from angioplasty to stent were put together with patients randomized to stenting, creating a population of 170 patients treated with stent and 119 patients treated by angioplasty alone. The restenosis rates according to this analysis showed no statistically significant differences (28.8% stent group versus 32.8% angioplasty group, P=NS).
Late Clinical Events
The cumulative major cardiac event rate at follow-up is shown in Table 4. The rate of occurrence of any events (death, myocardial infarction, or target-vessel revascularization) at 6 months was not significantly different (22% angioplasty versus 18.3% stent, P=0.40). The target-vessel revascularization rate was 20.3% in the angioplasty group and 17.8% in the stent group (P=0.54). The angina-free rate at 6 months was 72.2% in the angioplasty group and 76.2% in the stent group (P=NS).
|
| Discussion |
|---|
|
|
|---|
Patients with lesions in vessels with small reference diameters constitute a distinct population. Their clinical characteristics are different, including more women, fewer white patients, and more patients with diabetes mellitus, heart failure, and peripheral vascular disease.9 Lesions in small vessels tend to be more complex and more commonly associated with multivessel disease.9 As a result, percutaneous revascularizations in small vessels show lower rates of procedural success and higher rates of in-hospital major events.9 Small vessels, particularly those with long or diffuse lesions, are more prone to restenosis than larger vessels after both standard angioplasty10 and stent placement.12 At least part of this difference can be ascribed to the amount of late loss that can be accommodated before clinically important luminal narrowing recurs.13 There is a typical inverse relationship between arterial diameter and lesion length,23 which results in a higher plaque burden in small-vessel lesions.
Retrospective and observational studies have been reported on stenting in small coronary arteries.1117 A subgroup analysis from the STRESS trial comparing stand-alone balloon angioplasty to stent implantation examined the benefit of stenting in small arteries, defined as a reference diameter <3 mm identified post hoc by quantitative coronary angiography.11 The mean reference diameter was 2.65 mm, and angiographic restenosis rates were 34% for stented lesions and 55% in the angioplasty group. Smaller trials in <3 mm or <2.8 mm arteries showed restenosis rates between 32% and 39% after stenting.1217 Recently, 2 randomized trials comparing stent with balloon angioplasty in small vessels were published.18,19 In the ISAR-SMART study,18 angiographic restenosis (
50% diameter stenosis) was found in 35.7% of stented patients and 37.4% of PTCA patients (P=0.74). The protocol was very similar to this study with a 404-patient population, an average vessel size of 2.4 mm, and a 16.5% crossover rate to stent. All patients received adjunctive therapy with abciximab (none in our study), and the stent used was the MULTI-LINK stent. Also, in the ISAR-SMART study, there was no difference in adverse events at 30 days. In comparison, our trial showed better clinical success with stent (95.3% versus 87.9%, P=0.0066) and a trend to fewer complications (3% versus 7.1%, P=0.076). The second randomized trial19 included only 120 patients, and the restenosis rate was 30.9% in the angioplasty group and 35.7% in the stent group (P=NS) using the 7-cell NIR 2.5-mm stent.
The findings of the present trial are in agreement with these 2 recently-published randomized trials in showing no difference in the primary end point of restenosis. Several explanations could account for this lack of significant differences. In the power calculation, the predicted restenosis rate for the stent arm was set between 43% and 25%. The observed rate was 28%. On the other hand, for the balloon group, the actual restenosis rate was 32.9%, which is relatively low for small arteries and better than the predicted range of 35% to 52%. Even excluding crossovers to stent, the restenosis rate remained 32.8%. One reason for the lack of significant difference could be the excellent performance of the balloon. The availability of stents for bailout may presently permit a more aggressive dilatation strategy and provides better results with balloon angioplasty only. Another explanation may be differences in populations. Compared with all other studies in which the efficacy of stenting to prevent restenosis had been proven,27 our trial included a higher-risk population. With 46% of the population having complex lesions (type B2 or C) and 32% having unstable angina and a lesion length of 10.4 mm, our population was clearly different from that of previously published trials. Therefore, the efficacy of stenting to prevent restenosis may have been negated by lesion characteristics. Another potential explanation for lack of significant differences is that the balloon-to-artery ratio and final pressure were significantly different between the balloon and the stent group. A higher balloon-to-artery ratio is associated with greater wall damage and consequently more potent intimal hyperplasia stimulus.24 The limitation of available space for the hyperplastic response in small vessels may highlight the need for a more gentle approach in this particular population.
There are some potential limitations to this trial. First, small coronary arteries were defined as vessels 2.3 to 2.9 mm according to online QCA interpolation of the proximal and distal references. This is an arbitrary definition that can create an inhomogeneous group in terms of restenosis risk, although it is clearly distinct from the previously studied stent population. A second limitation is related to the atherosclerosis process, which may be diffuse in nature, so that the diseased vessel may be reduced in caliber along its entire length, giving the angiographic impression of a small vessel. Ultrasound may be the only way to obtain an accurate measurement of the true normal reference.25 We then could have included in our trial larger vessels with diffuse disease that represent a completely different population compared with small vessels with discrete lesions. A third limitation is related to stent design and strut thickness, which can influence outcomes in small vessels. Our findings may not be generalizable to all types of stents. Finally, technical variables, especially regarding stent deployment and maximum atmosphere, were left to operators choice and may have introduced bias in this large multicenter trial.
In conclusion, stenting and PTCA are associated with equal restenosis rate in small coronary arteries. With lower in-hospital complication rates, stenting may be a superior strategy in this population.
Appendix
The following institutions and investigators, in addition to the authors, participated in the Stent In Small Arteries (SISA) trial: R. Bonan, G. Côté, J. Crépeau, P. de Guise, R. Gallo, G. Gosselin, J. Grégoire, M. Joyal, J.-F. Tanguay, Montreal Heart Institute, Montreal, Canada; J. Van Lierde, Ziekenhuis Oost Limburg, Genk, Belgium; W.P. Klinke, R.D. Kinloch, M.B. Williams, Royal Jubilee Hospital, Victoria, Canada; O. Gorne, E. Schroeder, Catholic University of Louvain-UCL-Mont-Godinne Hospital, Mont-Godinne, Belgium; W. Wijns, G.R. Heyndrickx, Cardiovascular Center, Aalst, Belgium; P. Chandra, A. Mathur, Escorts Heart Institute and Research Center, New Delhi, India; P. Ngarmukos, Chulalongkorn University Hospital, Bangkok, Thailand; H.D. Glogar, P. Yang, M. Pavone-Gyöngyöst, University of Vienna Medical Center, Vienna, Austria; F. Reeves, G. Leclerc, R.M. Gagnon, A. Rivard, CHUM, Notre-Dame Pavillon, Montreal, Canada; L. Schwartz, Toronto General Hospital, Toronto, Canada; M.J. Pieper, Herz-Zentrum Bodensee, Kreuzlingen, Switzerland; M. Curtis, M. Knudtson, M. Traboulsi, T. Anderson, F. Spence, J. Hansen, Foothills Hospital, Calgary, Canada; D. Tresukosol, S. Chaithiraphan, Siriraj Hospital, Mahïdol University, Bangkok, Thailand; B.J. ONeill, L.M. Title, R.J. Teskey, C.J. Foster, C.M. Kells, Queen Elizabeth II Health Sciences Center, Halifax, Canada; G. Barbeau, L. Roy, O. Gleeton, S. Plante, G. Proulx, C. Juneau, Laval Hospital, Quebec, Canada; E. Schampaert, D. Palisaïtis, P. Tessier, P. Terriault, D. Hamel, Hôpital du Sacré-C
ur, Montreal, Canada; G. Heyer, Invasive Kardiologie, Salzburg, Austria; L. Missault, L. Muyldermans, St-Jan Hospital, Brugge, Belgium; E. Von Hodenberg, U. Berninger, Heart Center, Lahr/Baden, Germany; H. Mudra, A. König, Medezinische Klinik, Klinikum Innenstad, University of Munich, Munich, Germany; L. Giommi, E. Franceschini, G. Risica, Ospedale Regionale DellAzienda, Treviso, Italy; A. Chauhan, Blackpool Victoria Hospital, Blackpool, United Kingdom; C. Costantini, Clinica Cardiologyca C. Constantini, Curitiba, Brazil. Steering Committee: S. Doucet (Chairperson) and L. Bilodeau, Montreal, Canada; M. Schalij, Leiden, The Netherlands; F. van Leeuwen, Maastricht, The Netherlands. Adverse Event Adjudication Committee: V.L. Legrand, Liège, Belgium; P. van den Heuvel, Middelheim, Belgium. Data and Safety Monitoring Board: M.G. Bourassa, Montreal, Canada; M. Bertrand, Lille, France; A.V.G. Bruschke, Leiden, The Netherlands. Quantitative Angiographic Core Laboratories: A.W.M. van Weert, J.H.C. Reiber, E. Hekking, J. ter Horst and Y. Ishii, Leiden, The Netherlands; J. Lesperance, L. Bilodeau, F. Bélanger, C. Desjardins and M.J. Dussault, Montreal, Canada. Data Coordinating Management: S. Jacobs, Maastricht, The Netherlands. Sponsor: Medtronic Vascular, Maastricht, The Netherlands.
| Acknowledgments |
|---|
| Footnotes |
|---|
Received March 14, 2001; accepted August 15, 2001.
| References |
|---|
|
|
|---|
2.
Serruys PW, de Jaegere P, Kiemeneij F, et al. A comparison of balloon-expandable-stent implantation with balloon angioplasty in patients with coronary artery disease: Benestent Study Group. N Engl J Med. 1994; 331: 489495.
3.
Fischman DL, Leon MB, Baim DS, et al for the Stent Restenosis Study Investigators. A randomized comparison of coronary-stent placement and balloon angioplasty in the treatment of coronary artery disease: Stent Restenosis Study Investigators. N Engl J Med. 1994; 331: 496501.
4.
Buller CE, Dzavik V, Carere RG, et al. Primary stenting versus balloon angioplasty in occluded coronary arteries: the Total Occlusion Study of Canada (TOSCA). Circulation. 1999; 100: 236242.
5.
Versaci F, Gaspardone A, Tomai F, et al. A comparison of coronary-artery stenting with angioplasty for isolated stenosis of the proximal left anterior descending coronary artery. N Engl J Med. 1997; 336: 817822.
6.
Erbel R, Haude M, Hopp HW, et al. Coronary-artery stenting compared with balloon angioplasty for restenosis after initial balloon angioplasty: Restenosis Stent Study Group. N Engl J Med. 1998; 339: 16721678.
7.
Grines CL, Cox D, Stone GW, et al. Coronary angioplasty with or without stent implantation for acute myocardial infarction: Stent Primary Angioplasty in Myocardial Infarction Study Group. N Engl J Med. 1999; 341: 19491956.
8.
Holmes DR, Hirshfeld J, Faxon D, et al. ACC expert consensus document on coronary artery stents. J Am Coll Cardiol. 1998; 32: 14711482.
9.
Schunkert H, Harrell L, Palacios IF. Implications of small reference vessel diameter in patients undergoing percutaneous coronary revascularization. J Am Coll Cardiol. 1999; 34: 4048.
10.
Foley DP, Melkert R, Serruys PW. Influence of coronary vessel size on renarrowing process and late angiographic outcome after successful balloon angioplasty. Circulation. 1994; 90: 12391251.
11.
Savage MP, Fischman DL, Rake R, et al. Efficacy of coronary stenting versus balloon angioplasty in small coronary arteries: Stent Restenosis Study (STRESS) Investigator. J Am Coll Cardiol. 1998; 31: 307311.
12.
Elezi S, Kastrati A, Neumann FJ, et al. Vessel size and long-term outcome after coronary stent placement. Circulation. 1998; 98: 18751880.
13.
Akiyama T, Moussa I, Reimers B, et al. Angiographic and clinical outcome following coronary stenting of small vessels. J Am Coll Cardiol. 1998; 32: 16101618.
14. Morice MC, Bradai R, Lefevre T, et al. Stenting small coronary arteries. J Invasive Cardiol. 1999; 11: 337340.[Medline] [Order article via Infotrieve]
15. Eeckhout E, Grobety M, Vogt P, et al. Corrective use of the 2.5-mm GFX stent for suboptimal angioplasty results in small coronary arteries. Catheter Cardiovasc Interv. 1999; 48: 157161.[Medline] [Order article via Infotrieve]
16. Huang P, Levin T, Kabour A, Feldman T. Acute and late outcome after use of 2.5-mm intracoronary stents in small (<2.5 mm) coronary arteries. Catheter Cardiovasc Interv. 2000; 49: 121126.[Medline] [Order article via Infotrieve]
17. Cohen MG, Kong DF, Warner JJ, et al. Outcomes following interventions in small coronary arteries with the use of hand-crimped Palmaz-Schatz stents. Am J Cardiol. 2000; 85: 446450.[Medline] [Order article via Infotrieve]
18.
Kastrati A, Schömig A, Dirschinger J, et al. A randomized trial comparing stenting with balloon angioplasty in small vessels in patients with symptomatic coronary artery disease. Circulation. 2000; 102: 25932598.
19.
Park SW, Lee CW, Hong MK, et al. Randomized comparison of coronary stenting with optimal balloon angioplasty for treatment of lesions in small coronary arteries. Eur Heart J. 2000; 21: 17851789.
20. Reiber JHC, van der Zwet PMJ, von Land CD, et al. Quantitative coronary arteriography: equipment and technical requirements.In: Reiber JHC, Serruys PW, eds. Advances in Quantitative Coronary Arteriography. Dordrecht, The Netherlands: Kluwer Academic Publishers; 1993: 75111.
21. van Weert AWM, Lespérance J, Reiber JHC. Standardization of central off-line quantitative image analysis: implications from experiences with quantitative coronary angiography. Heart Drug. 2000; 1: 4451.
22.
Ellis SG, Vandormael MG, Cowley MJ, et al. Coronary morphologic and clinical determinants of procedural outcome with angioplasty for multivessel coronary disease: multivessel angioplasty prognosis study group. Circulation. 1990; 82: 11931202.
23. Goldberg SL. The arteries are small: the challenge is large. J Invasive Cardiol. 1999; 11: 351352.[Medline] [Order article via Infotrieve]
24. Serruys PW, Foley DP, Kirkeeide RL, et al. Restenosis revisited: insights provided by quantitative coronary angiography. Am Heart J. 1993; 126: 12431267.[Medline] [Order article via Infotrieve]
25. Mintz GS, Painter JA, Pichard AD, et al. Atherosclerosis in angiographically "normal" coronary artery reference segments: an intravascular ultrasound study with clinical correlations. J Am Coll Cardiol. 1995; 25: 14791485.[Abstract]
This article has been cited by other articles:
![]() |
B. L. van der Hoeven, S.-S. Liem, J. Dijkstra, S. C. Bergheanu, H. Putter, M. L. Antoni, D. E. Atsma, M. Bootsma, K. Zeppenfeld, J. W. Jukema, et al. Stent Malapposition After Sirolimus-Eluting and Bare-Metal Stent Implantation in Patients with ST-Segment Elevation Myocardial Infarction: Acute and 9-Month Intravascular Ultrasound Results of the MISSION! Intervention Study J. Am. Coll. Cardiol. Intv., April 1, 2008; 1(2): 192 - 201. [Abstract] [Full Text] [PDF] |
||||
![]() |
B. L. van der Hoeven, S.-S. Liem, J. W. Jukema, N. Suraphakdee, H. Putter, J. Dijkstra, D. E. Atsma, M. Bootsma, K. Zeppenfeld, P. V. Oemrawsingh, et al. Sirolimus-eluting stents versus bare-metal stents in patients with ST-segment elevation myocardial infarction: 9-month angiographic and intravascular ultrasound results and 12-month clinical outcome results from the MISSION! Intervention Study. J. Am. Coll. Cardiol., February 12, 2008; 51(6): 618 - 626. [Abstract] [Full Text] [PDF] |
||||
![]() |
J. Mehilli, A. Dibra, A. Kastrati, J. Pache, J. Dirschinger, A. Schomig, and for the Intracoronary Drug-Eluting Stenting to Abr Randomized trial of paclitaxel- and sirolimus-eluting stents in small coronary vessels Eur. Heart J., February 1, 2006; 27(3): 260 - 266. [Abstract] [Full Text] [PDF] |
||||
![]() |
J. Pache, A. Dibra, J. Mehilli, J. Dirschinger, A. Schomig, and A. Kastrati Drug-eluting stents compared with thin-strut bare stents for the reduction of restenosis: a prospective, randomized trial Eur. Heart J., July 1, 2005; 26(13): 1262 - 1268. [Abstract] [Full Text] [PDF] |
||||
![]() |
L. Mauri, E. J. Orav, and R. E. Kuntz Late Loss in Lumen Diameter and Binary Restenosis for Drug-Eluting Stent Comparison Circulation, June 28, 2005; 111(25): 3435 - 3442. [Abstract] [Full Text] [PDF] |
||||
![]() |
P. Agostoni, G. G.L. Biondi-Zoccai, G. L. Gasparini, M. Anselmi, G. Morando, M. Turri, A. Abbate, E. P. McFadden, C. Vassanelli, P. Zardini, et al. Is bare-metal stenting superior to balloon angioplasty for small vessel coronary artery disease? Evidence from a meta-analysis of randomized trials Eur. Heart J., May 1, 2005; 26(9): 881 - 889. [Abstract] [Full Text] [PDF] |
||||
![]() |
D. Ardissino, C. Cavallini, E. Bramucci, C. Indolfi, A. Marzocchi, A. Manari, G. Angeloni, G. Carosio, E. Bonizzoni, S. Colusso, et al. Sirolimus-Eluting vs Uncoated Stents for Prevention of Restenosis in Small Coronary Arteries: A Randomized Trial JAMA, December 8, 2004; 292(22): 2727 - 2734. [Abstract] [Full Text] [PDF] |
||||
![]() |
R. Moreno, C. Fernandez, F. Alfonso, R. Hernandez, M. J. Perez-Vizcayno, J. Escaned, M. Sabate, C. Banuelos, D. J. Angiolillo, L. Azcona, et al. Coronary stenting versus balloon angioplasty in small vessels: A meta-analysis from 11 randomized studies J. Am. Coll. Cardiol., June 2, 2004; 43(11): 1964 - 1972. [Abstract] [Full Text] [PDF] |
||||
![]() |
A. J Nordmann, P. Hengstler, B. M Leimenstoll, T. Harr, J. Young, and H. C Bucher Clinical outcomes of stents versus balloon angioplasty in non-acute coronary artery disease: A meta-analysis of randomized controlled trials Eur. Heart J., January 1, 2004; 25(1): 69 - 80. [Abstract] [Full Text] [PDF] |
||||
![]() |
J. M. Brophy, P. Belisle, and L. Joseph Evidence for Use of Coronary Stents: A Hierarchical Bayesian Meta-Analysis Ann Intern Med, May 20, 2003; 138(10): 777 - 786. [Abstract] [Full Text] [PDF] |
||||
![]() |
M. Haude, T. F.M. Konorza, U. Kalnins, A. Erglis, K. Saunamaki, H. D. Glogar, E. Grube, R. Gil, A. Serra, H. G. Richardt, et al. Heparin-Coated Stent Placement for the Treatment of Stenoses in Small Coronary Arteries of Symptomatic Patients Circulation, March 11, 2003; 107(9): 1265 - 1270. [Abstract] [Full Text] [PDF] |
||||
![]() |
V. Spanos, G. Stankovic, J. Tobis, and A. Colombo The challenge of in-stent restenosis: insights from intravascular ultrasound Eur. Heart J., January 2, 2003; 24(2): 138 - 150. [Full Text] [PDF] |
||||
![]() |
E. Regar, P.W. Serruys, C. Bode, C. Holubarsch, J.L. Guermonprez, W. Wijns, A. Bartorelli, C. Constantini, M. Degertekin, K. Tanabe, et al. Angiographic Findings of the Multicenter Randomized Study With the Sirolimus-Eluting Bx Velocity Balloon-Expandable Stent (RAVEL): Sirolimus-Eluting Stents Inhibit Restenosis Irrespective of the Vessel Size Circulation, October 8, 2002; 106(15): 1949 - 1956. [Abstract] [Full Text] [PDF] |
||||
![]() |
A. Colombo, G. Stankovic, and J. W. Moses Selection of coronary stents J. Am. Coll. Cardiol., September 18, 2002; 40(6): 1021 - 1033. [Abstract] [Full Text] [PDF] |
||||
![]() |
P. B. Shah and C. M. Lilly Interventional Therapy for Coronary Artery Disease Am. J. Respir. Crit. Care Med., September 15, 2002; 166(6): 791 - 796. [Full Text] |
||||
![]() |
J.o. Hausleiter, A. Kastrati, J. Mehilli, H. Schuhlen, J.u. Pache, F. Dotzer, J. Dirschinger, and A. Schomig Predictive factors for early cardiac events and angiographic restenosis after coronary stent placement in small coronary arteries J. Am. Coll. Cardiol., September 4, 2002; 40(5): 882 - 889. [Abstract] [Full Text] [PDF] |
||||
![]() |
C. Briguori, C. Sarais, P. Pagnotta, F. Liistro, M. Montorfano, A. Chieffo, F. Sgura, N. Corvaja, R. Albiero, G. Stankovic, et al. In-stent restenosis in small coronary arteries: Impact of strut thickness J. Am. Coll. Cardiol., August 7, 2002; 40(3): 403 - 409. [Abstract] [Full Text] [PDF] |
||||
| |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
|
Circulation Home | Subscriptions | Archives | Feedback | Authors | Help | AHA Journals Home | Search Copyright © 2001 American Heart Association, Inc. All rights reserved. Unauthorized use prohibited. |