Donate Help Contact The AHA Sign In Home
American Heart Association
Circulation
Search: search_blue_button Advanced Search
Circulation. 2000;102:2823-2828

This Article
Right arrow Abstract Freely available
Right arrow Full Text (PDF)
Right arrow Alert me when this article is cited
Right arrow Alert me if a correction is posted
Right arrow Citation Map
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Download to citation manager
Right arrow Request Permissions
Citing Articles
Right arrow Citing Articles via HighWire
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Achenbach, S.
Right arrow Articles by Moshage, W.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Achenbach, S.
Right arrow Articles by Moshage, W.
Right arrowPubmed/NCBI databases
Medline Plus Health Information
*CT Scans
Related Collections
Right arrow Coronary imaging: angiography/ultrasound/Doppler/CC
Right arrow CT and MRI

(Circulation. 2000;102:2823.)
© 2000 American Heart Association, Inc.


Clinical Investigation and Reports

Noninvasive Coronary Angiography by Retrospectively ECG-Gated Multislice Spiral CT

Stephan Achenbach, MD; Stefan Ulzheimer, MS; Ulrich Baum, MD; Marc Kachelrieß, PhD; Dieter Ropers, MD; Tom Giesler, MD; Werner Bautz, MD; Werner G. Daniel, MD; Willi A. Kalender, PhD; Werner Moshage, MD

From the Department of Internal Medicine II (S.A., D.R., T.G., W.G.D., W.M.), Institute of Medical Physics (S.U., M.K., W.A.K.), and Department of Diagnostic Radiology (U.B., W.B.), University of Erlangen-Nürnberg, Germany.

Correspondence to PD Dr Stephan Achenbach, Medizinische Klinik II mit Poliklinik, Universität Erlangen-Nürnberg, Östliche Stadtmauerstr 29, D-91054 Erlangen, Germany. E-mail stephan.achenbach{at}rzmail.uni-erlangen.de


*    Abstract
up arrowTop
*Abstract
down arrowIntroduction
down arrowMethods
down arrowResults
down arrowDiscussion
down arrowReferences
 
Background—We investigated the applicability and image quality of contrast-enhanced coronary artery visualization by multislice spiral CT using retrospective ECG gating.

Methods and Results—Twenty-five patients in sinus rhythm (significant coronary artery stenoses ruled out by invasive angiography) were studied with a multislice spiral CT (Siemens SOMATOM Volume Zoom). In inspiration (mean breathhold, 37 seconds), a volume data set of the heart was acquired (intravenous contrast agent; 4x1-mm slice thickness; 500-ms rotation; table feed, 1.5 mm/360°). Simultaneous recording of the ECG permitted retrospective reconstruction of contiguous cross sections in intervals of 1 mm at any desired interval of the cardiac cycle. The mean duration of the image reconstruction window was 185 ms. Next to 3-dimensional reconstructions of the heart and coronary arteries, multiplanar reconstructions were rendered to determine the visualized length of the coronary arteries, the contrast-to-noise ratio, and the correlation of coronary artery diameters to quantitative coronary angiography.

Conclusions—The coronary arteries could be visualized over long segments (left main, 9±4 mm; left anterior descending, 112±34 mm; left circumflex, 80±29 mm; right coronary artery, 116±33 mm). On average, 78±16% of these distances were visualized free of motion artifacts. The mean contrast-to-noise ratio was 9.3±3.3. Coronary artery diameters in multislice spiral CT showed close correlation to quantitative coronary angiography (CT, 3.3±1.0 mm; angiography, 3.2±0.9 mm; mean difference, 0.38 mm; r=0.86). Contrast-enhanced multislice spiral CT permits visualization of the coronary artery lumen. Further studies are necessary to determine whether image quality is sufficient to reliably detect coronary artery stenoses.


Key Words: imaging • coronary disease • tomography


*    Introduction
up arrowTop
up arrowAbstract
*Introduction
down arrowMethods
down arrowResults
down arrowDiscussion
down arrowReferences
 
X-ray coronary angiography is considered the diagnostic standard for establishing the presence of coronary artery stenoses. Because this technique has limitations as a result of its invasive nature with a small, nevertheless not negligible, procedure-related mortality (0.15%) and morbidity (1.5%) rates1 2 and relatively high cost, attempts have been made to image the coronary artery lumen with noninvasive methods. MRI3 4 5 6 7 8 9 10 and especially electron-beam tomography (EBT)11 12 13 14 15 16 17 18 have been successfully used to visualize the coronary arteries. Although mechanical CT has been successfully used to demonstrate the patency of coronary artery bypass grafts,19 20 21 the temporal resolution of conventional CT scanners has so far not been sufficient to visualize native coronary arteries. During the past years, CT scanners with gantry rotation times <1 second have been introduced. By using retrospective ECG gating, cardiac CT imaging can be performed with data acquisition windows that are shorter than the rotation time of the scanner.22 This approach has been used to detect and quantify coronary calcification,23 24 and one case report of a stenosis of the left anterior descending coronary artery visualized by contrast-enhanced spiral CT with a temporal resolution of 0.4 second has been published.25 The latest generation of spiral CT scanners offers rotation times of 500 ms and the possibility to simultaneously acquire up to 4 parallel slices. The lower scan times and especially multislice acquisitions, in combination with retrospective ECG gating, allow the data acquisition window to be shortened even further.26 27 28 We investigated the applicability and image quality of contrast-enhanced coronary artery visualization using a multislice CT scanner of the latest generation and a new ECG-gated image reconstruction algorithm, 180° Multislice Cardiac Interpolation (180°MCI), the theoretical basis of which and advantage over other reconstruction algorithms have been described in detail elsewhere.26 27


*    Methods
up arrowTop
up arrowAbstract
up arrowIntroduction
*Methods
down arrowResults
down arrowDiscussion
down arrowReferences
 
Twenty-five consecutive patients (16 men and 9 women; mean age, 56 years; range, 39 to 80 years) were investigated. In all patients, invasive x-ray coronary angiography had been performed, and hemodynamically relevant coronary artery stenoses (>=50% diameter reduction) had been ruled out. All patients had sinus rhythm (heart rate, 51 to 115 bpm; mean, 77 bpm) and were in a clinically stable condition. The mean weight of the patients was 80.2 kg (range, 56 to 115 kg). All patients gave written informed consent, and the study protocol was approved by the institutional review board.

Multislice Spiral CT
Multislice spiral CT (SOMATOM Volume Zoom, Siemens AG) was performed 1 to 3 days after invasive angiography. Medications were maintained between the invasive angiogram and the multislice spiral CT study. All image acquisitions were performed in inspiratory breathhold preceded by mild hyperventilation. First, a noncontrast localization scan was performed that yielded an anteroposterior view of the chest; it was used to position the imaging volume for coronary artery imaging, which extended from the carina to {approx}1 cm below the diaphragmal face of the heart. In a second step, a bolus of 20 mL of contrast agent (Iohexol, Ultravist350, Schering AG) was injected intravenously at 4 mL/s via an 18-gauge catheter placed in the cubital vein. After a delay of 10 seconds, a sequence of 10 axial images at the level of the carina was acquired with an interval of 2 seconds between subsequent images. From the time interval between contrast agent injection and acquisition of the image with peak attenuation in the aortic root, the contrast agent transit time was determined. In a third step, the volume data set for coronary artery visualization was acquired in spiral mode, with simultaneous acquisition of 4 parallel slices with 1.0-mm collimation each. The gantry rotation time was 500 ms, and the patient table was continuously advanced at 3.0 mm/s. The tube current was 150 mA. During the scan, the patient’s ECG was digitized and continuously recorded.

Contrast agent (160 mL) was injected into the cubital vein at 4 mL/s, and the CT scan was initiated with a delay according to the previously determined contrast agent transit time. Using the PC program WinDose (Wellhöfer Dosimetrie/Scanditronix Medical), we estimated the effective radiation dose of the complete investigation to be between 3.9 mSv (men) and 5.8 mSv (women).

Image Reconstruction
The CT raw data were transferred to an offline, PC-based workstation. Next to ungated image reconstruction with a conventional spiral CT algorithm (180° Linear Interpolation; 180°LI),29 cross-sectional images with a slice thickness of 1.2 to 1.4 mm were reconstructed in 1-mm intervals with the new algorithm 180°MCI.27 In short, the algorithm collects spiral data from successive heart beats by applying a filter function not only in the z direction (along the patient’s longitudinal axis) but also in the heart phase. The planar data set acquired by this means then undergoes the normal, filtered backprojection process for image reconstruction in CT. The width of the image reconstruction window is expressed through the full-width tenth-maximum of the phase contribution profile,27 which strongly depends on the patient’s heart rate and was between 125 and 243 ms in our study (mean, 185±41 ms; see Figure 1Down). The field of view was 180 mm, with an image matrix of 512x512 pixels. For each patient, 10 data sets were created. For the first data set, the image acquisition window was centered around the peak of the R wave. For the second data set, the center was positioned at 10% of the R-R interval, and for the subsequent data sets, the center of the image acquisition window was moved toward the end of the cardiac cycle in increments of 10%. Because reconstruction of one cross-sectional image required {approx}2 seconds, 30 to 45 minutes was necessary to create all 10 data sets. All image data sets were inspected concerning the presence of motion artifacts, and for each coronary artery, the data set that contained the fewest motion artifacts was chosen for further evaluation.



View larger version (20K):
[in this window]
[in a new window]
 
Figure 1. Relationship between heart rate and duration of image reconstruction window (full-width tenth-maximum of heart phase contribution profile). RR indicates R-wave to R-wave interval.

Data Evaluation
The reconstructed images were transferred to a commercially available image processing workstation (NetraMD, ScImage) and evaluated by a single blinded observer. As measures of image quality, the visualized length of each coronary artery, the contrast-to-noise ratio (CNR), and the correlation of coronary artery diameters in multislice spiral CT and in quantitative x-ray coronary angiography were determined. For each artery (left main, left anterior descending, left circumflex, and right coronary artery), a curved multiplanar reconstruction was rendered as previously described.30 In the multiplanar reconstructions, the visualized length of each coronary artery was measured. In addition, the length of the vessel segments that were visually judged to be free of motion artifacts was determined. The CNR was determined for each coronary artery by measuring the mean CT density within the proximal artery lumen and the mean CT density in a region of interest in the connective tissue immediately next to the coronary artery and dividing the respective difference by the image noise (SD of CT density in a region of interest placed in the aortic root). Finally, the diameters of the left main and proximal left anterior descending, left circumflex, and right coronary artery were determined immediately before or after bifurcation points that could be identified in both multislice spiral CT and invasive coronary angiography. Diameters were measured by use of the principle of "full-width half-maximum":31 The multiplanar reconstructions were displayed with a window of 1 Hounsfield unit and a level that corresponded to one half of the peak CT density measured in the proximal coronary artery segment. The length of the shortest possible line that could be drawn across the coronary artery lumen was considered to represent the coronary artery diameter.

In addition, 3-dimensional reconstructions were created with the "volume rendering technique" after manual segmentation of the data sets to remove structures that would obstruct the view onto the coronary arteries, such as the chest wall, pulmonary trunk, and atrial appendages.

Quantitative Coronary Angiography
The x-ray coronary angiograms of all patients were evaluated by means of QCA. The tip of the angiography catheter was used for calibration, and the vessel diameters of the coronary segments corresponding to those used for determination of the artery diameter in multislice spiral CT were measured in 2 orthogonal planes with automated contour detection. The mean of the 2 obtained values was considered to represent the actual vessel diameter at that site. Diameters were measured at the same time instant in the cardiac cycle as in multislice spiral CT.


*    Results
up arrowTop
up arrowAbstract
up arrowIntroduction
up arrowMethods
*Results
down arrowDiscussion
down arrowReferences
 
Multislice spiral CT was performed successfully and without complications in all 25 patients. The mean duration of the complete imaging procedure was 17±3 minutes. The mean craniocaudal distance of the volume data set needed to cover the heart was 110±11 mm (range, 90 to 137 mm). The mean duration of the breathhold therefore was 37±4 seconds (range, 30 to 46 seconds). Three patients were unable to hold their breath during the complete duration of the scan; their data were included in the analysis.

Using retrospective ECG gating with the image reconstruction algorithm 180°MCI, we could suppress cardiac motion artifacts in most images (see Figure 2Down). The cardiac phase that yielded optimal image quality varied strongly from patient to patient and between different coronary arteries. For the left main and left anterior descending coronary arteries, optimal image quality was usually achieved if the data acquisition window was centered at 70% or 80% of the cardiac cycle, whereas for the left circumflex and right coronary arteries, the most frequent "optimal" position of the data acquisition window was at 50% of the cardiac cycle (see the TableDown). In 3-dimensional reconstructions, it was possible to visualize the anatomy of the heart and coronary arteries (see Figures 3Down and 4Down). The mean visualized length of the left main coronary artery was 9±4 mm (range, 4 to 17 mm). The mean visualized length of the left anterior descending coronary was 112±34 mm (range, 52 to 155 mm); left circumflex coronary artery, 80±29 mm (range, 22 to 139 mm); and right coronary artery, 116±33 mm (range, 45 to 176 mm). Artifacts caused by coronary artery motion were not always fully suppressed and usually affected the mid right coronary artery and distal segments of the left anterior descending coronary artery and left circumflex coronary artery (see Figure 5Down). Although the left main coronary artery was free of visible motion artifact in all cases, the mean proportion of the left anterior descending coronary artery that was visualized free of motion artifact was 79±16% (range, 55% to 100%). The mean proportion of the left circumflex coronary artery that was visualized free of motion artifact was 79±17% (range, 41% to 100%), and on average, the right coronary artery could be visualized free of motion artifact over 75±14% (range, 54% to 100%) of its entire length.



View larger version (166K):
[in this window]
[in a new window]
 
Figure 2. Cross-sectional images acquired by contrast-enhanced multislice spiral CT in patient with heart rate of 77 bpm. A, Ungated image (reconstruction algorithm, 180°LI; 500-ms image acquisition time) at level of left main and proximal left anterior descending coronary arteries showing moderate motion artifacts. B, Retrospectively ECG-gated image at same level using reconstruction window of 215 ms centered at 70% of cardiac cycle. Decreased motion artifacts permit clearer visualization of proximal left anterior descending coronary artery (arrow). C, Ungated image (500-ms acquisition time) at level of mid right coronary artery. Severe motion artifacts prevent visualization of right coronary artery. D, Retrospectively ECG-gated image at same level using reconstruction window of 215 ms centered at 50% of cardiac cycle. Decreased motion artifacts permit clear visualization of right coronary artery (large arrow) and side branch (small arrow). Note also improved visualization of left anterior descending coronary (arrowhead) and left circumflex coronary (open arrow) arteries.


View this table:
[in this window]
[in a new window]
 
Table 1. Distribution of Optimal Positions of the Image Reconstruction Window Relative to the Cardiac Cycle



View larger version (82K):
[in this window]
[in a new window]
 
Figure 3. Three-dimensional reconstruction of heart and coronary arteries obtained with volume rendering technique. By manual segmentation of cross-sectional images, pulmonary trunk and atrial appendages were removed to permit visualization of proximal coronary arteries. A, View from anterior face of heart showing short left main and left anterior descending coronary arteries (large arrow), as well as left circumflex coronary artery (small arrow; image reconstruction window centered at 80% of cardiac cycle). B, Inferior and lateral view showing right coronary artery (arrow; image reconstruction window centered at 70% of cardiac cycle).



View larger version (154K):
[in this window]
[in a new window]
 
Figure 4. Three-dimensional reconstruction (volume rendering technique) showing anomalous origin of right coronary artery (small arrow) from left sinus of valsalva, as well as normal left main and left anterior descending coronary arteries (large arrow; image reconstruction window centered at 70% of cardiac cycle).



View larger version (94K):
[in this window]
[in a new window]
 
Figure 5. Multiplanar reconstructions of right coronary artery in 2 patients. A, Patient with a heart rate of 67 bpm. Reconstruction at 60% of cardiac cycle. Right coronary artery is visualized free of visible motion artifacts over its entire length (137 mm). B, Patient with heart rate of 71 bpm. Reconstruction at 50% of cardiac cycle. Right coronary artery is affected by motion artifact in its proximal and mid segments (dotted line). Overall visualized length is 103 mm. Visualized length without motion artifact is 62 mm.

The mean CNR determined for the proximal coronary arteries was 9.3±3.3 (left main, 8.9±4.1; left anterior descending, 9.9±3.4; left circumflex, 9.3±2.7; and right coronary artery, 9.3±2.8).

Coronary artery diameters were compared between multislice spiral CT and QCA at 100 points (see Figure 6Down). The mean coronary artery diameter in multislice spiral CT was 3.3±1.0 mm (range, 1.5 to 7.6 mm); the mean diameter in QCA was 3.2±0.9 mm (range, 1.6 to 6.2 mm). The mean absolute difference between the CT and angiographic measurement was 0.38±0.35 mm (range, 0.0 to 1.4 mm). There was no significant difference between diameters in QCA and multislice spiral CT. The slope of the regression line was 0.87, the intercept was 0.32, and the correlation coefficient was 0.86.



View larger version (116K):
[in this window]
[in a new window]
 
Figure 6. Measurement of vessel diameters in multislice spiral CT and QCA. A, Multiplanar reconstruction of left main (small arrow) and left anterior descending coronary arteries (large arrow; arrowhead shows diagonal branch). B, Enlarged segment indicated by box. Multiplanar reconstruction is displayed with window of 1 Hounsfield unit and level of 158 Hounsfield units, corresponding to one half the maximum attenuation within lumen of left anterior descending coronary artery in this segment. Vessel diameter is then measured immediately proximal to origin of diagonal branch (arrows). Vessel diameter here is 0.34 mm. C, Corresponding measurement of vessel diameter in QCA (0.35 mm; only 1 projection shown). D, Correlation between vessel diameters measured in multislice spiral CT (MSCT) and QCA. Correlation coefficient is 0.86.


*    Discussion
up arrowTop
up arrowAbstract
up arrowIntroduction
up arrowMethods
up arrowResults
*Discussion
down arrowReferences
 
Reliable noninvasive visualization of the coronary artery lumen through the use of mechanical CT scanners has so far not been possible because of the limited temporal resolution that conventional CT systems provide. The latest generation of spiral CT scanners, however, allows continuous acquisition of data with 4 parallel detectors and, with the use of the patient’s ECG, which is stored with the CT data, retrospective reconstruction of cross-sectional images of the heart with a data acquisition window that is shorter than the rotation time of the CT scanner’s gantry.26 27 28 We investigated the clinical applicability and image quality of retrospectively ECG-gated cardiac imaging using a multislice spiral CT scanner in a group of patients with sinus rhythm and no significant stenoses of the coronary arteries. We could demonstrate that multislice spiral CT with retrospective ECG gating and a new, sophisticated image reconstruction algorithm (180°MCI) permits visualization of the coronary arteries with high image quality. The coronary arteries could be visualized over longer segments than previously reported for early studies by EBT12 and MRI.3 4 5 6 8 The CNR achieved for the proximal coronary arteries was approximately equal to that reported for EBT.12 The high spatial resolution of multislice spiral CT is expressed through the fact that vessel diameters correlated closely to invasive, x-ray coronary angiography. However, motion artifacts resulting from rapid coronary artery motion were not completely eliminated and frequently affected the mid sections of the right coronary artery and the distal segments of the left anterior descending and left circumflex coronary artery. This may limit the applicability of the method, and further studies are necessary to determine whether motion artifacts can be sufficiently suppressed to permit reliable detection of significant coronary artery stenoses.

One major drawback of retrospectively ECG-gated spiral CT is the fact that radiation is continuously applied, whereas image reconstruction is restricted to data acquired during only a fraction of the cardiac cycle. It is doubtful whether prospective triggering algorithms—yet to be developed—would lead to a substantial reduction in radiation exposure, because the optimal positioning of the image reconstruction window used varies from patient to patient and between the different coronary arteries. Based on our data, only a relatively small portion of the cardiac cycle ({approx}20%) could potentially be excluded from data acquisition. Also, coronary artery visualization by spiral CT requires intravenous injection of iodinated contrast agent, which may lead to side effects and necessitates perfect timing of image acquisition to contrast injection. Minor reductions in the amount of contrast injection could be achieved by exactly adapting the amount of contrast used to the duration of data acquisition, which depends on the craniocaudal distance of the volume data set, instead of using a standard dose of 160 mL as we did in our study protocol. Another limitation is the relatively long breathhold. At the cost of increased slice thickness, however, the speed of table movement could be increased, leading to a shorter overall scan duration required to cover the volume of the heart. Further investigations are necessary to determine the optimal balance between breathhold duration and slice thickness, which translates into image resolution along the patient’s longitudinal axis.

In conclusion, multislice spiral CT with retrospective ECG gating is an interesting new approach for noninvasive coronary artery imaging. It could be demonstrated that the coronary arteries can be visualized with high spatial resolution and good overall image quality, although artifacts caused by motion, especially of the right coronary artery, can so far not be sufficiently eliminated. In the future, the accuracy of this approach concerning the detection of coronary artery stenoses will have to be determined, and the method needs to be compared against other evolving and established techniques for coronary artery visualization, such as MRI and EBT.

Received June 9, 2000; revision received July 20, 2000; accepted July 21, 2000.


*    References
up arrowTop
up arrowAbstract
up arrowIntroduction
up arrowMethods
up arrowResults
up arrowDiscussion
*References
 

  1. Kennedy JW. Complications associated with cardiac catheterization and angiography. Cath Cardiovasc Diagn. 1982;8:5–11.[Medline] [Order article via Infotrieve]
  2. Davidson CJ, Fishman RF, Bonow RO. Cardiac catheterization. In: Braunwald E, ed. Heart Disease: A Textbook of Cardiovascular Medicine. Philadelphia, Pa: WB Saunders; 1997;177–203.
  3. Manning WJ, Li W, Boyle NG, et al. Fat-suppressed breath-hold magnetic resonance coronary angiography. Circulation. 1993;87:94–104.[Abstract/Free Full Text]
  4. Pennell DJ, Keegan J, Firmin DN, et al. Magnetic resonance imaging of coronary arteries: technique and preliminary results. Br Heart J. 1993;70:315–326.[Abstract/Free Full Text]
  5. Duerinckx AJ, Urman MK. Two-dimensional coronary MR angiography: analysis of initial clinical results. Radiology. 1994;193:731–738.[Abstract/Free Full Text]
  6. Hofman MBM, Paschal CB, Li D, et al. MRI of coronary arteries: 2D breath-hold vs 3D respiratory-gated acquisition. J Comput Assist Tomogr. 1995;19:56–62.[Medline] [Order article via Infotrieve]
  7. Wielopolski PA, van Geuns RJM, de Feyter PJ, et al. Breath-hold coronary MR angiography with volume targeted imaging. Radiology. 1998;209:209–219.[Abstract/Free Full Text]
  8. Stuber M, Botnar RM, Danias PG, et al. Double-oblique free-breathing high resolution three-dimensional coronary magnetic resonance coronary angiography. J Am Coll Cardiol. 1999;34:524–531.[Abstract/Free Full Text]
  9. van Geuns RJM, de Bruin HG, Rensing BJWM, et al. Magnetic resonance imaging of the coronary arteries: clinical results from three-dimensional evaluation of a respiratory gated technique. Heart. 1999;82:515–519.[Abstract/Free Full Text]
  10. Botnar RM, Stuber M, Kissinger KV, et al. Free-breathing 3D coronary MRA: the impact of "isotropic" image resolution. J Magn Reson Imaging. 2000;11:389–393.[Medline] [Order article via Infotrieve]
  11. Moshage W, Achenbach S, Seese B, et al. Coronary artery stenoses: three-dimensional imaging with electrocardiographically triggered, contrast agent-enhanced, electron-beam CT. Radiology. 1995;196:707–714.[Abstract/Free Full Text]
  12. Chernoff DM, Ritchie CJ, Higgins CB. Evaluation of electron beam CT coronary angiography in healthy subjects. Am J Roentgenol. 1997;169:93–99.[Abstract/Free Full Text]
  13. Nakanishi T, Ito K, Imazu M, et al. Evaluation of coronary artery stenoses using electron-beam CT and multiplanar reformation. J Comput Assist Tomogr. 1997;21:121–127.[Medline] [Order article via Infotrieve]
  14. Schmermund A, Rensing BJ, Sheedy PF, et al. Intravenous electron-beam computed tomographic coronary angiography for segmental analysis of coronary artery stenoses. J Am Coll Cardiol. 1998;31:1547–1554.[Abstract/Free Full Text]
  15. Reddy G, Chernoff DM, Adams JR, et al. Coronary artery stenoses: assessment with contrast-enhanced electron-beam CT and axial reconstructions. Radiology. 1998;208:167–172.[Abstract/Free Full Text]
  16. Rensing BJ, Bongaerts A, van Geuns RJ, et al. Intravenous coronary angiography by electron beam computed tomography: a clinical evaluation. Circulation. 1998;98:2509–2512.[Abstract/Free Full Text]
  17. Achenbach S, Moshage W, Ropers D, et al. Value of electron-beam computed tomography for the detection of high-grade coronary artery stenoses and occlusions. N Engl J Med. 1998;339:1964–1971.[Abstract/Free Full Text]
  18. Budoff MJ, Oudiz RJ, Zalace CP, et al. Intravenous three-dimensional coronary angiography using contrast-enhanced electron beam computed tomography. Am J Cardiol. 1999;83:840–845.[Medline] [Order article via Infotrieve]
  19. Daniel WG, Döhring W, Stender H-S, et al. Value and limitations of computed tomography in assessing aortocoronary bypass graft patency. Circulation. 1983;67:983–987.[Abstract/Free Full Text]
  20. Tello R, Costello P, Ecker C, et al. Spiral CT evaluation of coronary artery bypass graft patency. J Comput Assist Tomogr. 1993;17:253–259.[Medline] [Order article via Infotrieve]
  21. Steiner P, Phillips F, Stiel G, et al. The value of spiral computed tomography in the imaging of aortocoronary bypass vessels. Rofo Fortschr Geb Rontgenstr Nuklearmed. 1994;160:23–29.
  22. Kachelrieß M, Kalender WA. ECG-correlated image reconstruction from subsecond spiral computed tomography scans of the heart. Med Phys. 1998;25:2417–2431.[Medline] [Order article via Infotrieve]
  23. Woodhouse CE, Janowitz WR, Viamonte M. Coronary arteries: retrospective cardiac gating technique to reduce cardiac motion artifact at spiral CT. Radiology. 1997;204:566–569.[Abstract/Free Full Text]
  24. Becker CR, Knez A, Jakobs TF, et al. Detection and quantification of coronary artery calcification with electron-beam and conventional CT. Eur Radiol. 1999;9:620–624.[Medline] [Order article via Infotrieve]
  25. Mochizuki T, Murase K, Koyama Y, et al. Images in cardiovascular medicine: LAD stenosis detected by subsecond spiral CT. Circulation. 1999;99:1523.[Free Full Text]
  26. Kachelrieß M, Ulzheimer S, Kalender WA. ECG-correlated imaging of the heart with subsecond multislice spiral CT. IEEE Trans Med Imaging 2000. In press.
  27. Kachelrieß M, Ulzheimer S, Kalender WA. ECG-correlated image reconstruction from subsecond multislice spiral CT scans of the heart. Med Phys. 2000;27:1881-1902.[Medline] [Order article via Infotrieve]
  28. Ohnesorge B, Flohr T, Becker C, et al. Cardiac imaging with rapid, retrospectively ECG synchronized multilevel spiral CT. Radiologe. 2000;40:111–117.[Medline] [Order article via Infotrieve]
  29. Kalender W, Seissler W, Klotz E, et al. Spiral volumetric CT with single-breath-hold technique, continuous transport and continuous scanner rotation. Radiology. 1990;176:181–183.[Abstract/Free Full Text]
  30. Achenbach S, Moshage W, Ropers D, et al. Curved multiplanar reconstructions for the evaluation of contrast-enhanced electron beam CT of the coronary arteries. Am J Roentgenol. 1998;170:895–899.[Abstract/Free Full Text]
  31. Rumberger JA. Principles and practice of cardiac edge-detection and border definition using ultrafast computed tomography. In: Stanford W, Rumberger JA, eds. Ultrafast Computed Tomography: Principles and Practice. Mount Kisco, NY: Futura Publishing Co; 1992:25–36.



This article has been cited by other articles:


Home page
Am. J. Roentgenol.Home page
M. Nagao, H. Matsuoka, H. Kawakami, H. Higashino, T. Mochizuki, K. Murase, and M. Uemura
Quantification of Myocardial Perfusion by Contrast-Enhanced 64-MDCT: Characterization of Ischemic Myocardium
Am. J. Roentgenol., July 1, 2008; 191(1): 19 - 25.
[Abstract] [Full Text] [PDF]


Home page
Am. J. Roentgenol.Home page
X. Fei, X. Du, Q. Yang, Y. Shen, P. Li, J. Liao, and K. Li
64-MDCT Coronary Angiography: Phantom Study of Effects of Vascular Attenuation on Detection of Coronary Stenosis
Am. J. Roentgenol., July 1, 2008; 191(1): 43 - 49.
[Abstract] [Full Text] [PDF]


Home page
J Am Coll Cardiol IntvHome page
S. Voros
Can Computed Tomography Angiography of the Coronary Arteries Characterize Atherosclerotic Plaque Composition?: Is the CAT (Scan) Out of the Bag?
J. Am. Coll. Cardiol. Intv., April 1, 2008; 1(2): 183 - 185.
[Full Text] [PDF]


Home page
Am. J. Roentgenol.Home page
C. L. Hollingsworth, T. T. Yoshizumi, D. P. Frush, F. P. Chan, G. Toncheva, G. Nguyen, C. R. Lowry, and L. M. Hurwitz
Pediatric Cardiac-Gated CT Angiography: Assessment of Radiation Dose
Am. J. Roentgenol., July 1, 2007; 189(1): 12 - 18.
[Abstract] [Full Text] [PDF]


Home page
CirculationHome page
D. Ropers, F.-K. Pohle, A. Kuettner, T. Pflederer, K. Anders, W. G. Daniel, W. Bautz, U. Baum, and S. Achenbach
Diagnostic Accuracy of Noninvasive Coronary Angiography in Patients After Bypass Surgery Using 64-Slice Spiral Computed Tomography With 330-ms Gantry Rotation
Circulation, November 28, 2006; 114(22): 2334 - 2341.
[Abstract] [Full Text] [PDF]


Home page
J Am Coll CardiolHome page
S. Achenbach
Computed Tomography Coronary Angiography
J. Am. Coll. Cardiol., November 21, 2006; 48(10): 1919 - 1928.
[Abstract] [Full Text] [PDF]


Home page
CirculationHome page
M. J. Budoff, S. Achenbach, R. S. Blumenthal, J. J. Carr, J. G. Goldin, P. Greenland, A. D. Guerci, J. A.C. Lima, D. J. Rader, G. D. Rubin, et al.
Assessment of Coronary Artery Disease by Cardiac Computed Tomography: A Scientific Statement From the American Heart Association Committee on Cardiovascular Imaging and Intervention, Council on Cardiovascular Radiology and Intervention, and Committee on Cardiac Imaging, Council on Clinical Cardiology
Circulation, October 17, 2006; 114(16): 1761 - 1791.
[Full Text] [PDF]


Home page
J. Lipid Res.Home page
J. R. Crouse III
Thematic review series: Patient-Oriented Research. Imaging atherosclerosis: state of the art
J. Lipid Res., August 1, 2006; 47(8): 1677 - 1699.
[Abstract] [Full Text] [PDF]


Home page
Am. J. Roentgenol.Home page
K. Nikolaou, A. Knez, C. Rist, B. J. Wintersperger, A. Leber, T. Johnson, M. F. Reiser, and C. R. Becker
Accuracy of 64-MDCT in the diagnosis of ischemic heart disease.
Am. J. Roentgenol., July 1, 2006; 187(1): 111 - 117.
[Abstract] [Full Text] [PDF]


Home page
Am. J. Roentgenol.Home page
K. Nikolaou, C. Rist, B. J. Wintersperger, T. F. Jakobs, R. van Gessel, M. A. Kirchin, A. Knez, F. von Ziegler, M. F. Reiser, and C. R. Becker
Clinical value of MDCT in the diagnosis of coronary artery disease in patients with a low pretest likelihood of significant disease.
Am. J. Roentgenol., June 1, 2006; 186(6): 1659 - 1668.
[Abstract] [Full Text] [PDF]


Home page
J Am Coll CardiolHome page
P. Zanzonico, L. N. Rothenberg, and H. W. Strauss
Radiation Exposure of Computed Tomography and Direct Intracoronary Angiography: Risk Has its Reward
J. Am. Coll. Cardiol., May 2, 2006; 47(9): 1846 - 1849.
[Abstract] [Full Text] [PDF]


Home page
J Am Coll CardiolHome page
D. R. Coles, M. A. Smail, I. S. Negus, P. Wilde, M. Oberhoff, K. R. Karsch, and A. Baumbach
Comparison of Radiation Doses From Multislice Computed Tomography Coronary Angiography and Conventional Diagnostic Angiography
J. Am. Coll. Cardiol., May 2, 2006; 47(9): 1840 - 1845.
[Abstract] [Full Text] [PDF]


Home page
HeartHome page
C Peebles
Computed tomographic coronary angiography: how many slices do you need?
Heart, May 1, 2006; 92(5): 582 - 584.
[Abstract] [Full Text] [PDF]


Home page
J Am Coll CardiolHome page
U. Hoffmann, F. Moselewski, K. Nieman, I.-K. Jang, M. Ferencik, A. M. Rahman, R. C. Cury, S. Abbara, H. Joneidi-Jafari, S. Achenbach, et al.
Noninvasive Assessment of Plaque Morphology and Composition in Culprit and Stable Lesions in Acute Coronary Syndrome and Stable Lesions in Stable Angina by Multidetector Computed Tomography
J. Am. Coll. Cardiol., April 18, 2006; 47(8): 1655 - 1662.
[Abstract] [Full Text] [PDF]


Home page
J Am Coll CardiolHome page
M. A.S. Cordeiro and J. A.C. Lima
Atherosclerotic plaque characterization by multidetector row computed tomography angiography.
J. Am. Coll. Cardiol., April 18, 2006; 47(8 Suppl): C40 - C47.
[Abstract] [Full Text] [PDF]


Home page
RadiologyHome page
C. Jahnke, I. Paetsch, S. Achenbach, B. Schnackenburg, R. Gebker, E. Fleck, and E. Nagel
Coronary MR Imaging: Breath-hold Capability and Patterns, Coronary Artery Rest Periods, and {beta}-Blocker Use
Radiology, April 1, 2006; 239(1): 71 - 78.
[Abstract] [Full Text] [PDF]


Home page
CirculationHome page
J. Hausleiter, T. Meyer, M. Hadamitzky, E. Huber, M. Zankl, S. Martinoff, A. Kastrati, and A. Schomig
Radiation Dose Estimates From Cardiac Multislice Computed Tomography in Daily Practice: Impact of Different Scanning Protocols on Effective Dose Estimates
Circulation, March 14, 2006; 113(10): 1305 - 1310.
[Abstract] [Full Text] [PDF]


Home page
RadiologyHome page
H. Alkadhi, S. Wildermuth, D. A. Bettex, A. Plass, B. Baumert, S. Leschka, L. M. Desbiolles, B. Marincek, and T. Boehm
Mitral Regurgitation: Quantification with 16-Detector Row CT--Initial Experience
Radiology, December 21, 2005; (2005) 2381042216.
[Abstract] [Full Text]


Home page
Proc Am Thorac SocHome page
G. Kohl
The Evolution and State-of-the-Art Principles of Multislice Computed Tomography
Proceedings of the ATS, December 1, 2005; 2(6): 470 - 476.
[Abstract] [Full Text] [PDF]


Home page
HeartHome page
N E Manghat, G J Morgan-Hughes, A J Marshall, and C A Roobottom
Multidetector row computed tomography: imaging congenital coronary artery anomalies in adults
Heart, December 1, 2005; 91(12): 1515 - 1522.
[Abstract] [Full Text] [PDF]


Home page
Eur Heart JHome page
S. Achenbach, D. Ropers, F.-K. Pohle, D. Raaz, J. von Erffa, A. Yilmaz, G. Muschiol, and W. G. Daniel
Detection of coronary artery stenoses using multi-detector CT with 16x0.75 collimation and 375 ms rotation
Eur. Heart J., October 1, 2005; 26(19): 1978 - 1986.
[Abstract] [Full Text] [PDF]


Home page
Eur Heart JHome page
C. Kaiser, J. Bremerich, S. Haller, H. P. Brunner-La Rocca, G. Bongartz, M. Pfisterer, and P. Buser
Limited diagnostic yield of non-invasive coronary angiography by 16-slice multi-detector spiral computed tomography in routine patients referred for evaluation of coronary artery disease
Eur. Heart J., October 1, 2005; 26(19): 1987 - 1992.
[Abstract] [Full Text] [PDF]


Home page
Am. J. Roentgenol.Home page
H. Alkadhi, D. Bettex, S. Wildermuth, B. Baumert, A. Plass, J. Grunenfelder, L. Desbiolles, B. Marincek, and T. Boehm
Dynamic Cine Imaging of the Mitral Valve with 16-MDCT: A Feasibility Study
Am. J. Roentgenol., September 1, 2005; 185(3): 636 - 646.
[Abstract] [Full Text] [PDF]


Home page
JNMHome page
M. Hacker, T. Jakobs, F. Matthiesen, C. Vollmar, K. Nikolaou, C. Becker, A. Knez, T. Pfluger, M. Reiser, K. Hahn, et al.
Comparison of Spiral Multidetector CT Angiography and Myocardial Perfusion Imaging in the Noninvasive Detection of Functionally Relevant Coronary Artery Lesions: First Clinical Experiences
J. Nucl. Med., August 1, 2005; 46(8): 1294 - 1300.
[Abstract] [Full Text] [PDF]


Home page
Eur Heart JHome page
S. Leschka, H. Alkadhi, A. Plass, L. Desbiolles, J. Grunenfelder, B. Marincek, and S. Wildermuth
Accuracy of MSCT coronary angiography with 64-slice technology: first experience
Eur. Heart J., August 1, 2005; 26(15): 1482 - 1487.
[Abstract] [Full Text] [PDF]


Home page
Am. J. Roentgenol.Home page
T. H. Kim, J. Hur, S. J. Kim, H. S. Kim, B. W. Choi, K. O. Choe, Y. W. Yoon, and H. M. Kwon
Two-Phase Reconstruction for the Assessment of Left Ventricular Volume and Function Using Retrospective ECG-Gated MDCT: Comparison with Echocardiography
Am. J. Roentgenol., August 1, 2005; 185(2): 319 - 325.
[Abstract] [Full Text] [PDF]