Donate Help Contact The AHA Sign In Home
American Heart Association
Circulation
Search: search_blue_button Advanced Search
Circulation. 2000;101:258-263

This Article
Right arrow Abstract Freely available
Right arrow Full Text (PDF)
Right arrow Alert me when this article is cited
Right arrow Alert me if a correction is posted
Right arrow Citation Map
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Download to citation manager
Right arrow Request Permissions
Citing Articles
Right arrow Citing Articles via HighWire
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Smart, S. C.
Right arrow Articles by Sagar, K. B.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Smart, S. C.
Right arrow Articles by Sagar, K. B.
Related Collections
Right arrow Hypertrophy
Right arrow Exercise testing
Right arrow Echocardiography

(Circulation. 2000;101:258.)
© 2000 American Heart Association, Inc.


Clinical Investigation and Reports

Dobutamine-Atropine Stress Echocardiography for the Detection of Coronary Artery Disease in Patients With Left Ventricular Hypertrophy

Importance of Chamber Size and Systolic Wall Stress

Steven C. Smart, MD; Thomas Knickelbine, MD; Fayaz Malik, MD; Kiran B. Sagar, MD

From the Division of Cardiology, Medical College of Wisconsin, Milwaukee.

Correspondence to Kiran B. Sagar, MD, Medical College of Wisconsin, Division of Cardiovascular Medicine, 9200 W Wisconsin Ave, Milwaukee, WI 53226.


*    Abstract
up arrowTop
*Abstract
down arrowIntroduction
down arrowMethods
down arrowResults
down arrowDiscussion
down arrowReferences
 
Background—Left ventricular hypertrophy is a heterogeneous disorder with distinct morphologies. Changes in wall thickness, left ventricular chamber diameter, and mass alter systolic wall stress of the left ventricle and may influence ischemic threshold. Thus, the goal of this study was to investigate the effect of the different patterns of left ventricular hypertrophy on the accuracy of dobutamine-atropine stress echocardiography.

Methods and Results—Three-hundred eighty-six patients underwent multistage dobutamine-atropine stress echocardiography and diagnostic angiography. Echocardiograms were measured for mean and relative wall thicknesses, chamber size, left ventricular mass, and end-systolic wall stress. The patterns of ventricular hypertrophy were concentric hypertrophy (increased wall thickness and mass), eccentric hypertrophy (normal wall thickness and increased mass), and concentric remodeling (increased wall thickness and normal mass). The overall sensitivity, specificity, and accuracy of dobutamine-atropine stress echocardiography for the detection of coronary artery disease were 85%, 87%, and 86%, respectively. Increased left ventricular mass index alone did not affect accuracy. Sensitivity was markedly reduced (36%) only in those with concentric remodeling. The univariate predictors of false-negative studies were single-vessel left circumflex disease, increased wall thickness, small chamber size, hyperdynamic ejection fraction, and left ventricular concentric remodeling. Multivariate predictors were concentric remodeling (P<0.0001; odds ratio, 13.5), left ventricular ejection fraction >2 SD above normal (P<0.0001), and single-vessel left circumflex disease (P<0.0007; odds ratio, 7.6). Sensitivity was excellent in patients with small ventricles and normal wall thickness and in those with normal or large chambers regardless of wall thickness.

Conclusions—Dobutamine-atropine stress echocardiography is an accurate test in most patients with left ventricular hypertrophy, but it is insensitive in the small subset with concentric remodeling.


Key Words: hypertrophy • echocardiography • coronary disease


*    Introduction
up arrowTop
up arrowAbstract
*Introduction
down arrowMethods
down arrowResults
down arrowDiscussion
down arrowReferences
 
Left ventricular (LV) hypertrophy has heterogeneous morphologies with variable changes in LV mass, volume, wall thickness, diameter, systolic wall stress, and coronary flow reserve.1 2 3 4 5 6 By definition, the adaptive variations in wall thickness and ventricular size result in different systolic meridional wall stress, which may alter the threshold for demand-based ischemia2 and may impair the capacity of dobutamine atropine stress echocardiography to detect coronary artery disease.

LV hypertrophy has no influence on the accuracy of exercise stress echocardiography.7 8 However, the effect of LV hypertrophy on the accuracy of dobutamine-atropine stress echocardiography remains unclear, especially in relation to LV wall thickness, chamber diameter, and systolic meridional wall stress. In the present study, we postulated that LV morphology, specifically wall thickness/diameter, and systolic meridional wall stress significantly influence the accuracy of dobutamine-atropine stress echocardiography to detect coronary artery disease. The specific aim of the study was to determine the effect of LV mass, wall thickness, chamber size, and systolic meridional wall stress on the sensitivity and specificity of dobutamine-atropine stress echocardiography.


*    Methods
up arrowTop
up arrowAbstract
up arrowIntroduction
*Methods
down arrowResults
down arrowDiscussion
down arrowReferences
 
Patient Selection
Between July 1992 and June 1996, 386 patients with known or suspected coronary artery disease underwent both dobutamine-atropine stress echocardiography and diagnostic coronary angiography within 1 month of each other at the Milwaukee County Medical Complex. All patients gave informed consent. Exclusion criteria were recent myocardial infarction (<1 month), unstable angina, severe hypertension (blood pressure >220 mm Hg or diastolic pressure >120 mm Hg), or sustained ventricular tachycardia. Hypertension was blood pressure >160/90 mm Hg.

Dobutamine stress echocardiography, image acquisition, and analysis were performed according to previously published methods.9 10 11 LV septal thickness, posterior wall thickness, and chamber size were measured in the parasternal long axis at end diastole from the digitized images.12 Specular boundary echoes were excluded from the septum and posterior wall and were included in the LV diameter measurement.12 These 2-dimensional (2D) measurements were validated by correlation studies to M-mode measurements derived from the 2D parasternal long-axis view in a series of 25 patients. There were highly linear correlations between digitized 2D and M-mode measurements of wall thickness and LV diameter in diastole and systole, relative wall thickness, and LV mass. Mean wall thickness (MWT) was the average of septal and posterior wall thicknesses. End-diastolic relative wall thickness (RWT) was the ratio of (2xposterior wall thickness)/LVID, where LVID is LV chamber size in diastole. LV volumes and ejection fraction (LVEF) were obtained at end diastole and end systole at rest by use of the apical 4-chamber view and application of the modified Simpson’s rule method.13 LV mass was calculated by the method reported by Devereux and Reichek.14 LV wall stress was calculated at rest in systole as the average meridional stress with uniform wall thickness and homogeneous elasticity assumed as P(LVESD)/4h(1+h/LVESD), where LVESD is LV end-systolic diameter, P is LV pressure, and h is mean systolic wall thickness.2

To ensure standardization of measured values with a representative population at our institution, an age-matched series of 100 dobutamine stress echocardiograms interpreted as "normal" were measured by use of the same methods and identical reading criteria (Table 1Down).


View this table:
[in this window]
[in a new window]
 
Table 1. Mean±SD of Measured Values in 100 Normal Dobutamine Echocardiograms

The control group was made up of patients who had a very low likelihood of coronary artery disease. They had no risk factors for coronary artery disease, had normal baseline ECGs, and were referred for dobutamine stress echocardiograms for preoperative clearance for atypical chest pain

Each study echocardiogram was classified as having normal or abnormal measurements with the use of the sex-specific control population for comparison. We used 2 SD above the mean to define increased MWT, RWT, LVID, and increased LV mass. They were used to classify ventricular morphology in each study patient into 1 of 4 anatomic categories: concentric hypertrophy patients had increased MWT, normal or elevated RWT, normal or elevated LVID, and increased mass index; eccentric hypertrophy patients had normal MWT, normal or small RWT, enlarged LVID, and increased mass index; concentric remodeling patients had increased MWT, increased RWT, small LVID, and normal mass index; and normal patients were within normal limits of MWT, RWT, LVID, and mass index.

Results of coronary angiography were interpreted by an experienced angiographer without knowledge of the clinical and echocardiographic data. Percent luminal diameter stenosis of all coronary stenoses was determined by the caliper technique.15 The criterion for coronary stenosis was >=50% luminal diameter stenosis of any epicardial coronary artery or major branch.

Statistical Analysis
Continuous data are expressed as mean±SD. The {chi}2 analysis or Fisher’s exact test was used to compare categorical data.16 Continuous data were compared by multiway ANOVA and Bonferroni’s t test.16 Hemodynamic changes during dobutamine-atropine echocardiography were compared by repeated-measures ANOVA and Bonferroni’s t test. Linear and sigmoidal (Chapman 3-parameter) regression analyses were used to compare the relationships of sensitivity, specificity, and wall stress (Sigmaplot 4.0, SPSS, Inc). Stepwise multiple logistic regression analysis was used to identify independent causes of false-negative and false-positive results. A 2-tailed value of P<0.05 was significant.


*    Results
up arrowTop
up arrowAbstract
up arrowIntroduction
up arrowMethods
*Results
down arrowDiscussion
down arrowReferences
 
Patient Data
The 386 patients enrolled in the study had a mean age of 61±12 years. There were 133 women and 253 men. One hundred twenty patients were treated with ß-adrenergic blocking agents, 127 with calcium channel blockers, and 169 with nitrates or other vasodilators. Hypertension was documented in 242 patients.

Dobutamine Infusion
The mean peak dose of dobutamine was 26±12 µg · kg-1 · min-1. Atropine (0.2 to 2.0 mg) was used in 176 patients (46%). Resting heart rate, systolic blood pressure, and rate-pressure product were 71±13 bpm, 134±23 mm Hg, and 9563±418 mm Hg/min, respectively. Mean peak heart rate, systolic blood pressure, and rate-pressure product increased to 127±17 bpm, 142±37 mm Hg, and 18 150±5103 mm Hg/min, respectively. End points for peak dose were heart rate >120 bpm in 310 patients, severe anginal chest pain in 18, maximum dose in 32, nonsustained ventricular tachycardia (5 to 8 beat runs) in 7, hypotension in 6, hypertension in 3, multiple inducible wall motion abnormalities at a submaximal heart rate in 7, and severe nausea or vomiting in 3.

Coronary Angiography
Coronary angiography detected significant coronary artery disease in 280 patients (73%). There were 169 patients with multivessel coronary artery disease and 111 with single-vessel disease. Of these 111 patients, 87 had stenosis >=70% and 24 had stenosis between 50% and 69%. Of the patients with single-vessel disease, 38 had left anterior descending disease, 21 had left circumflex disease, and 52 had right coronary artery disease.

Dobutamine Echocardiographic Data
There were 122 normal and 264 abnormal stress echocardiograms. The sensitivity and specificity of wall motion abnormalities for detecting coronary artery disease were 85% (238 of 280) and 87% (92 of 106), respectively. The positive predictive values of fixed resting and induced wall motion abnormalities were 97% (60 of 62) and 94% (178 of 190), respectively. The negative predictive value of a normal dobutamine-atropine stress echocardiogram or sustained improvement in all vascular territories was 69% (92 of 134). Sensitivity was higher (P<0.05) for multivessel disease (88%, 149 of 169) than single-vessel disease (80%, 89 of 111) and for single-vessel disease and >=70% stenosis (87%, 76 of 87) than single-vessel disease and 50% to 69% stenosis (54%, 13 of 24). Sensitivity was 85% (44 of 52) in single-vessel right coronary artery disease, 84% (32 of 38) in single-vessel left anterior descending disease, but only 62% (13 of 21, P<0.05) in single-vessel left circumflex disease. False-positive studies occurred only in patients with isolated wall motion abnormalities in the right coronary or left circumflex vascular territories (14% [14 of 98] versus 0% [0 of 35] for left anterior descending only and 0% [0 of 119] for multiple wall motion abnormalities, P<0.01). Sensitivity was higher (P<0.001) in patients with abnormal resting wall motion (98% [61 of 62] versus 81% [177 of 218] in patients with normal resting wall motion), but specificity was similar (83% [10 of 12] versus 87% [82 of 94], respectively, P=NS).

Echocardiographic Measurements
The normal database (Table 1Up) revealed that the criterion for increased wall thickness was >=1.1 cm for men and women. A small chamber in diastole was <=4.1 cm in men and <=3.9 cm in women. A dilated chamber in diastole was >=5.8 cm in men and >=5.5 cm in women. Low and high LVEFs were <45% and >67%, respectively, in both men and women.

Effects of Echocardiograms and Clinical Findings on Accuracy in Normal Resting Wall Motion
In the 312 patients without resting wall motion abnormalities, LV hypertrophy was present in 152 patients (Figure 1Down): concentric hypertrophy in 93, eccentric hypertrophy in 14, and concentric remodeling in 45. Table 2Down outlines the echocardiographic measurements and clinical data for the different types of LV hypertrophy, normal left ventricles, small left ventricles with normal wall thickness, and resting wall motion abnormalities. Hypertension and LV mass did not alter the accuracy of dobutamine-atropine stress echocardiography for detection of coronary artery disease. In the 194 patients with hypertension, sensitivity and specificity were 80% (110 of 138) and 84% (47 of 56), respectively. In the 118 normotensive patients, sensitivity and specificity were similar at 84% (67 of 80) and 92% (35 of 38). In the 82 patients with increased LV mass index, sensitivity and specificity were 87% (48 of 55) and 85% (23 of 27). In the 230 patients with normal mass, sensitivity and specificity were similar at 79% (129 of 163) and 88% (59 of 67).



View larger version (48K):
[in this window]
[in a new window]
 
Figure 1. Incidence of abnormal (Abn) resting wall motion (WM) and 3 patterns of LV hypertrophy in remaining patients with normal resting wall motion. LVD indicates LV diameter; WT, wall thickness.


View this table:
[in this window]
[in a new window]
 
Table 2. Echocardiographic Measurements and Clinical Data According to Hypertrophy Type

Figure 2Down shows the effects of wall thickness, chamber size, and relative wall thickness on accuracy in the detection of coronary artery disease. Increased wall thickness, small chamber size, and high relative wall thickness reduced sensitivity without altering specificity (P<0.05).



View larger version (91K):
[in this window]
[in a new window]
 
Figure 2. Sensitivity and specificity according to LV diameter (LVD), wall thickness (WT), and RWT in patients with normal resting wall motion. >2SD indicates >2 SD above normal mean; <2SD, <2 SD below normal mean. *P<0.01 vs normal or low wall thickness; ¶P<0.01 vs normal or high LV diameter; §P<0.01 vs normal or low RWT.

Figure 3Down compares sensitivity and specificity of dobutamine-atropine stress echocardiography in the 3 different types of hypertrophy, patients with normal wall thickness and small chamber size, and those with normal wall thickness and chamber size. The accuracy of dobutamine-atropine stress echocardiography was compromised only in the small subset of patients with concentric remodeling. Specificity was not affected by any of the hypertrophy patterns. Sensitivity was not altered by concentric or eccentric hypertrophy but was markedly reduced by concentric remodeling (P<0.01 versus all other groups). Sensitivity was preserved in patients with small chamber sizes and normal wall thickness.



View larger version (107K):
[in this window]
[in a new window]
 
Figure 3. Sensitivity and specificity in patients with normal resting wall motion and normal LV diameter (LDV) and wall thickness (WT), normal wall thickness with small diameter, concentric remodeling, concentric hypertrophy, and eccentric hypertrophy in patients. P<0.01 vs all other subsets.

Low meridional and circumferential wall stress was the only factor that distinguished patients with concentric remodeling from other groups. Figure 4Down plots the relationship of resting LV systolic meridional (top) and circumferential (bottom) wall stress and accuracy. Sensitivity was correlated (P<0.0001) with both meridional and circumferential wall stress by a sigmoidal relationship (r=0.98 and 0.97, respectively). In patients with normal or high meridional wall stress (>40 dynes/cm2), sensitivity was high (88%, 150 of 170). In patients with low meridional wall stress (<=40 dynes/cm2), sensitivity was low (54%, 26 of 48) and steeply decreased to 0 at a wall stress <=15 dynes/cm2. In patients with normal or high circumferential wall stress (>100 dynes/cm2), sensitivity was high (92%, 158 of 177). In patients with low meridional wall stress (<=100 dynes/cm2), sensitivity was low (44%, 18 of 41) and steeply decreased to 0 at a wall stress of <=40 dynes/cm2. Specificity did not correlate (P>0.2) with resting meridional or circumferential wall stress (r=0.163 and 0.017, respectively).



View larger version (19K):
[in this window]
[in a new window]
 
Figure 4. Regression analysis of relationship between sensitivity, specificity, and resting meridional and circumferential wall stress in patients with normal resting wall motion.

Multivariate Analysis of Data
The univariate causes of false-negative studies were increased wall thickness, small chamber size, concentric remodeling, increased relative wall thickness, low global resting LV wall stress, small diastolic volume, high LVEF, single-vessel coronary artery disease, and single-vessel left circumflex coronary artery disease. The multivariate predictors of false-negative studies were concentric remodeling (P<0.000001) and single-vessel coronary artery disease (P=0.0007). The univariate causes of false-positive studies were induced wall motion abnormalities, wall motion abnormalities isolated in a single vascular territory, and isolated wall motion abnormalities of the basal inferior and lateral walls. The only independent cause of false-positive studies was small wall motion abnormalities of the basal inferior or lateral wall (P<0.000001).

Intraobserver and Interobserver Variabilities
Intraobserver and interobserver variabilities of wall motion analysis were minimal in a representative subset of 60 patients, including 40 patients with and 20 patients without coronary artery disease. The interpretations of the 2 investigators regarding the presence or absence of wall motion abnormalities agreed in 92% (55 of 60). Intraobserver variability was assessed by 1 investigator. The 2 readings were concordant regarding the presence or absence of wall motion abnormalities in 97% (58 of 60).

Intraobserver variability of echocardiographic measurements was assessed in the same cohort of patients. The mean variabilities in chamber size and wall thickness were 0.1 and 0.1 cm, respectively. In a cohort of 100 patients, the correlation coefficient, y intercept, and slope of the relationship between M-mode and 2D measurements of wall thickness were 0.94, 0, and 0.99±0.004, respectively. These values for chamber size were 0.96, 0, and 1.00±0.004, respectively.


*    Discussion
up arrowTop
up arrowAbstract
up arrowIntroduction
up arrowMethods
up arrowResults
*Discussion
down arrowReferences
 
This study shows that patients with small LV chamber size and increased wall thickness, the pattern called concentric remodeling, exhibit an excessively high number of false-negative studies in the presence of significant angiographic coronary stenoses. Concentric remodeling was the strongest univariate and multivariate predictor of false-negative studies. In contrast, sensitivity was preserved in patients with small chamber size and normal wall thickness, concentric and eccentric hypertrophy. The presence of hypertension or increased LV mass index alone did not affect accuracy. Although adjunctive measures, such as the addition of intravenous atropine to augment heart rate response in patients taking ß-blocker therapy,17 have been shown to overcome decreases in sensitivity during dobutamine stress echocardiography, LV morphological patterns may represent the most important absolute limitation of its detection of coronary stenoses.

Ganau et al1 reported that LV hypertrophy occurred in 3 morphological patterns in a series of 165 hypertensive patients: increased ventricular mass and wall thickness as typical concentric hypertrophy, increased mass and normal wall thickness as eccentric hypertrophy, and increased wall thickness and normal LV mass as concentric remodeling. Chamber size is normal or large in concentric hypertrophy, large in eccentric hypertrophy, and small in concentric remodeling. These more direct definitions of specific patterns of hypertrophy may be needed in evaluations of the accuracy of stress echocardiography. Marwick et al18 reported that the accuracy of exercise echocardiography is not impaired in patients with LV hypertrophy. The definition of hypertrophy used, however, was increased LV mass index. The present study is concordant with these findings in that an absolute increase in LV mass index did not affect accuracy. However, our study demonstrates a significant reduction in sensitivity of dobutamine stress echocardiography in a small subset of patients with LV hypertrophy, concentric remodeling. Marwick et al7 reported that increased wall thickness (defined as wall thickness >1.2 mm) did not alter the sensitivity (73% versus 72%) or specificity (94% versus 83%) of dobutamine stress echocardiography. However, chamber size and LV mass were not documented, the peak heart rate was only 109±25 bpm, and atropine was not used. In the present study, sensitivity was decreased most prominently in patients with the combination of increased wall thickness and small LV chamber in concentric remodeling. Small chamber size in the absence of increased wall thickness was not associated with false-negative studies. In the present study, atropine was frequently used (44% of patients), the peak heart rate was higher (128±17 bpm), and the percentage of patients with increased wall thickness was higher (48%) than Marwick et al used.7

The sensitivity of dobutamine stress echocardiography for detection of coronary artery disease has been shown to range from 76% to 96%.19 20 Previous studies have identified submaximal stress, single-vessel disease, distal coronary artery disease, female sex, and ß-adrenergic blocker therapy as potential causes of false-negative studies.17 21

Specificity of dobutamine stress echocardiography has ranged from 60% to 95%.17 19 21 Inadequate endocardial visualization, myocardial ischemia caused by microvascular disease, and wall motion abnormalities unrelated to coronary artery disease (cardiomyopathy or left bundle-branch block) have been hypothesized to cause false-positive studies.7 22 Bach et al22 reported that the primary causes of false-positive dobutamine echocardiography were female sex, wall motion abnormalities of the basal segments of the posterior circulation, and intermediate coronary stenoses >=40%; however, fewer women were included in the present study. Patients with concentric remodeling commonly have hypertension and a high probability of microvascular coronary artery disease and impaired coronary flow reserve.23 In our study patients, neither concentric remodeling nor hypertension was a cause of false-positive results. These observations suggest that although microvascular coronary disease can lead to angina in patients with normal coronary arteries,4 these patients do not manifest significant clinically detectable wall motion abnormalities during the peak stress phase of dobutamine-atropine stress echocardiography.

One hypothesis to explain why small chamber size and increased wall thickness caused false-negative studies may be that these patients have an increased threshold for demand ischemia and induced wall motion abnormalities. A consequence of the marked increase in myocardial wall thickness and decrease in LV chamber size is reduced systolic wall stress and myocardial displacement during stress. The results of the present study demonstrate that reduced systolic wall stress causes sensitivity to plummet. Furthermore, hyperdynamic wall motion is common in these patients. Thus, ischemic segments that become hypokinetic or akinetic during stress may remain visually undetected because of minimal excursion distances and "tethering" from adjacent hyperdynamic segments.

Overestimation of noncritical stenosis by the caliper technique may contribute to reduced sensitivity9 ; however, only 24 of 111 (22%) of patients with single-vessel disease in the present study had a stenosis from 50% to 69%. Patients with intermediate coronary stenosis (40% to 70%) often do not have impaired coronary flow reserve.5 Sensitivity may be reduced in these patients, but this factor did not account for the reduced sensitivity in concentric remodeling patients. Therefore, our conclusions regarding the sensitivity of dobutamine-atropine stress echocardiography remain valid.

Sharp et al11 reported a sensitivity of 83% and specificity of 71% in patients with dilated cardiomyopathy. Sensitivity of dobutamine stress echocardiography for detection of triple-, double- and single-vessel disease was 100%, 83%, and 69% respectively. In our study, in patients with concentric remodeling (LVEF, 61%), sensitivity was 36% and specificity was 89% (Figure 3Up). In the group with eccentric hypertrophy and reduced LVEF, specificity was significantly reduced, similar to the results reported by Sharp et al.11

In conclusion, dobutamine-atropine stress echocardiography may not be the ideal test for the small subset of patients with small LV chamber, increased wall thickness, and high relative wall thickness, a pattern recognized as concentric remodeling, especially the extreme cases. In contrast, dobutamine-atropine stress echocardiography remains an accurate diagnostic test in patients with eccentric hypertrophy, those with typical concentric hypertrophy, and even those with small chambers but normal wall thickness.

Received April 27, 1999; revision received August 9, 1999; accepted August 26, 1999.


*    References
up arrowTop
up arrowAbstract
up arrowIntroduction
up arrowMethods
up arrowResults
up arrowDiscussion
*References
 

  1. Ganau A, Devereux RB, Roman MJ, de Simone G, Pickering TG, Saba PS, Vargiu P, Simongini I, Laragh JH. Patterns of left ventricular hypertrophy and geometric remodeling in essential hypertension. J Am Coll Cardiol. 1992;19:1550–1558.[Abstract]
  2. Grossman W, Jones D, McLaurin LP. Wall stress and patterns of hypertrophy in the human ventricle. J Clin Invest. 1975;56:56–64.
  3. Strauer BE. Ventricular function and coronary hemodynamics in hypertensive heart disease. Am J Cardiol. 1979;44:999–1006.[Medline] [Order article via Infotrieve]
  4. Marcus ML, Doty DB, Hiratzka LF, Wright CB, Eastham CL. Decreased coronary reserve: a mechanism for angina pectoris in patients with aortic stenosis and normal coronary arteries. N Engl J Med. 1982;307:1362–1366.[Abstract]
  5. Marcus ML, Koyanagi S, Harrison DG, Doty DB, Hiratzka LF, Eastham CL. Abnormalities in the coronary circulation that occur as a consequence of cardiac hypertrophy. Am J Med. 1983;75:62–66.
  6. Opherk D, Mall G, Zebe H, Schwarz F, Weihe E, Manthey J, Kubler W. Reduction of coronary reserve: a mechanism for angina pectoris in patients with arterial hypertension and normal coronary arteries. Circulation. 1984;69:1–7.[Abstract/Free Full Text]
  7. Marwick TH, Torelli J, Harjai K, Haluska B, Paskow FJ, Steward WJ, Thomas JD. Influence of left ventricular hypertrophy on detection of coronary artery disease using exercise echocardiography. J Am Coll Cardiol. 1995;5:1180–1186.
  8. Marwick T, D’Hondt A, Baudhuin T, Willemart B, Wijns W, Detry J, Melin J. Optimal use of dobutamine stress for the detection and evaluation of coronary artery disease: combination with echocardiography or scintigraphy, or both? J Am Coll Cardiol. 1993;22:159–167.[Abstract]
  9. Sawada SG, Segar DS, Ryan T, Brown SE, Dohan AM, Williams R, Fineberg NS, Armstrong WF, Feigenbaum H. Echocardiographic detection of coronary artery disease during dobutamine infusion. Circulation. 1991;83:1605–1614.[Abstract/Free Full Text]
  10. Arnese M, Fioretti PM, Cornel JH, Postma-Tjoa J, Reijis AEM, Roelandt JRTC. Akinesis becoming dyskinesis during high dose dobutamine stress echocardiography: a marker of myocardial ischemia or a mechanical phenomenon? Am J Cardiol. 1994;73:897–899.
  11. Sharp SM, Sawada SG, Segar DS, Ryan T, Kovacs R, Fineberg NS, Feigenbaum H. Dobutamine stress echocardiography: detection of coronary artery disease in patients with dilated cardiomyopathy. J Am Coll Cardiol. 1994;24:934–939.[Abstract]
  12. Devereux RB, Lutas EM, Casale PN, Kligfield P, Eisenberg RR, Hammond IW, Miller DH, Reis G, Alderman MH, Laragh JH. Standardization of M-mode echocardiographic left ventricular anatomic measurements. J Am Coll Cardiol. 1984;4:1222–1230.[Abstract]
  13. Wyatt HL, Heng MK, Meerbaum S, Gueret P, Hestenes J, Dula E, Corday E. Cross-sectional echocardiography, II: analysis of mathematic models for quantifying volume of formalin-fixed left ventricle. Circulation. 1980;6:1119–1125.
  14. Devereux RB, Reichek N. Echocardiographic determination of left ventricular mass in man: anatomic validation of the method. Circulation. 1977;55:613–618.[Abstract/Free Full Text]
  15. Kalbfleisch SJ, McGillem MJ, Pinto IMF, Kavanaugh KM, DeBoe SF, Mancini GBJ. Comparison of automated quantitative coronary angiography with caliper measurements of percent diameter stenosis. Am J Cardiol. 1990;65:1181–1184.[Medline] [Order article via Infotrieve]
  16. Wallenstein S, Zucker CL, Fleiss JL. Some statistical methods useful in circulation research. Circ Res. 1980;47:1–9.[Abstract/Free Full Text]
  17. McNeil AJ, Fioretti PM, El-Said EM, Salustri A, de Feyter PJ, Roelandt JR. Enhanced sensitivity for detection of coronary artery disease by addition of atropine to dobutamine stress echocardiography. Am J Cardiol. 1992;70:41–46.[Medline] [Order article via Infotrieve]
  18. Marwick TH, Torelli J, Harjai K, Haluska B, Pashkow FJ, Stewart WJ, Thomas JD. Influence of left ventricular hypertrophy on detection of coronary artery disease using exercise echocardiography. J Am Coll Cardiol. 1995;26:1180–1186.[Abstract]
  19. Martin TW, Seaworth JF, Johns JP, Pupa LE, Condos WR. Comparison of adenosine, dipyridamole, and dobutamine in stress echocardiography. Ann Intern Med. 1992;116:190–196.
  20. Markovitz PA, Armstrong WF. Accuracy of dobutamine stress echocardiography in detecting coronary artery disease. Am J Cardiol. 1992;69:1269–1273.[Medline] [Order article via Infotrieve]
  21. Cohen JL, Greene TO, Ottenweller J, Binenbaum SZ, Wilchfort SD, Kim CS. Dobutamine digital echocardiography for detecting coronary artery disease. Am J Cardiol. 1991;67:1311–1318.[Medline] [Order article via Infotrieve]
  22. Bach DS, Muller DW, Gros BJ, Armstrong WF. False positive dobutamine stress echocardiograms: characterization of clinical, echocardiographic and angiographic findings. J Am Coll Cardiol. 1994;24:928–933.[Abstract]
  23. Pichard AD, Gorlin R, Smith H, Ambrose J, Meller J. Coronary flow studies in patients with left ventricular hypertrophy of the hypertensive type: evidence for an impaired coronary vascular reserve. Am J Cardiol. 1981;47:547–554.[Medline] [Order article via Infotrieve]



This article has been cited by other articles:


Home page
RadiologyHome page
H. V. Dinh, J. Alvergue, J. Sayre, J. S. Child, V. S. Deshpande, G. Laub, and J. P. Finn
Isovolumic Cardiac Contraction on High-Temporal-Resolution Cine MR Images: Study in Heart Failure Patients and Healthy Volunteers
Radiology, August 1, 2008; 248(2): 458 - 465.
[Abstract] [Full Text] [PDF]


Home page
HeartHome page
R Senior, M Monaghan, H Becher, J Mayet, and P Nihoyannopoulos
Stress echocardiography for the diagnosis and risk stratification of patients with suspected or known coronary artery disease: a critical appraisal. Supported by the British Society of Echocardiography
Heart, April 1, 2005; 91(4): 427 - 436.
[Abstract] [Full Text] [PDF]


Home page
J CARDIOVASC PHARMACOL THERHome page
S. Satwani, G. W. Dec, and J. Narula
{beta}-Adrenergic Blockers in Heart Failure: Review of Mechanisms of Action and Clinical Outcomes
Journal of Cardiovascular Pharmacology and Therapeutics, October 1, 2004; 9(4): 243 - 255.
[Abstract] [PDF]


Home page
ANGIOLOGYHome page
F. Yalcin, H. Muderrisoglu, M. E. Korkmaz, B. Ozin, M. Baltali, and F. Yigit
The Effect of Dobutamine Stress on Left Ventricular Outflow Tract Gradients in Hypertensive Patients with Basal Septal Hypertrophy
Angiology, May 1, 2004; 55(3): 295 - 301.
[Abstract] [PDF]


Home page
J Am Coll CardiolHome page
A. E. Weyman
The year in echocardiography
J. Am. Coll. Cardiol., January 7, 2004; 43(1): 140 - 148.
[Full Text] [PDF]


Home page
J Am Coll CardiolHome page
W. Mathias Jr, J. M. Tsutsui, J. L. Andrade, I. Kowatsch, P. A. Lemos, S. M. B. Leal, B. K. Khandheria, and J. F. Ramires
Value of rapid beta-blocker injectionat peak dobutamine-atropine stressechocardiography for detection of coronary artery disease
J. Am. Coll. Cardiol., May 7, 2003; 41(9): 1583 - 1589.
[Abstract] [Full Text] [PDF]


Home page
J Am Coll CardiolHome page
A. Elhendy, K. M. Modesto, D. W. Mahoney, B. K. Khandheria, J. B. Seward, and P. A. Pellikka
Prediction of mortality in patients with left ventricular hypertrophy by clinical, exercise stress, and echocardiographic data
J. Am. Coll. Cardiol., January 1, 2003; 41(1): 129 - 135.
[Abstract] [Full Text] [PDF]


Home page
J Am Coll CardiolHome page
S. Yuda, V. Khoury, and T. H. Marwick
Influence of wall stress and left ventricular geometry on the accuracy of dobutamine stress echocardiography
J. Am. Coll. Cardiol., October 2, 2002; 40(7): 1311 - 1319.
[Abstract] [Full Text] [PDF]


Home page
HypertensionHome page
E. Bello, C. Caramelo, N. Martell, J. M. Alcazar, J. Gonzalez, M. D. Lopez, L. M. Ruilope, F. R. Gonzalez, A. M. Rovira, R. Gazapo, et al.
Impairment of Renal Vasodilation With L-Arginine Is Related to More Severe Disease in Untreated Hypertensive Patients
Hypertension, October 1, 2001; 38(4): 907 - 912.
[Abstract] [Full Text] [PDF]


Home page
J Am Coll CardiolHome page
E. Tadamura, H. Iida, K. Matsumoto, M. Mamede, S. Kubo, H. Toyoda, T. Shiozaki, T. Mukai, Y. Magata, and J. Konishi
Comparison of myocardial blood flow during dobutamine-atropine infusion with that after dipyridamole administration in normal men
J. Am. Coll. Cardiol., January 1, 2001; 37(1): 130 - 136.
[Abstract] [Full Text] [PDF]


This Article
Right arrow Abstract Freely available
Right arrow Full Text (PDF)
Right arrow Alert me when this article is cited
Right arrow Alert me if a correction is posted
Right arrow Citation Map
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Download to citation manager
Right arrow Request Permissions
Citing Articles
Right arrow Citing Articles via HighWire
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Smart, S. C.
Right arrow Articles by Sagar, K. B.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Smart, S. C.
Right arrow Articles by Sagar, K. B.
Related Collections
Right arrow Hypertrophy
Right arrow Exercise testing
Right arrow Echocardiography