(Circulation. 1999;100:II-295.)
© 1999 American Heart Association, Inc.
Aortic and Peripheral Vascular Surgery |
From the Department of Medicine II, Cardiology, University of Erlangen-Nürnberg, Erlangen, Germany (D.S.); the Departments of Medicine, Nephrology and Intensive Care Medicine (M.S.), and Radiology (J.O.B., H.S.), Charitè, Campus Virchow Klinikum, Humboldt University, Berlin, Germany; and Center for Cardiology and Vascular Intervention (G.B.), Hamburg, Germany.
Correspondence to Dierk Scheinert, MD, Medizinische Klinik II mit Poliklinik, Universität Erlangen-Nürnberg, Ösliche Stadtmauerstrasse 29, 91054 Erlangen, Germany.
| Abstract |
|---|
|
|
|---|
Methods and ResultsIn 48 patients with obstructions of the aortoiliac segment, primary stent implantation was performed with the "kissing balloon technique." Preinterventional angiography showed bilateral stenoses (>85%) of the proximal common iliac arteries in 25 patients, unilateral occlusions and contralateral stenosis in 22 patients, and bilateral occlusion in 1 patient. In 7 cases, stents were placed for the treatment of high-grade infrarenal aortic stenoses. After excimer laserassisted recanalization of the common iliac artery obstructions, the aortic bifurcation was reconstructed with the bilateral simultaneous implantation of Palmaz stents (diameter, 7 to 8 mm). Stents used for the treatment of aortic stenoses (Palmaz, n=6; Gianturco, n=1) had a diameter ranging from 20 to 25 mm. In all patients, stents were placed successfully (residual stenosis <30%) and without complications. A clinical improvement of +2 to +3 according to American Heart Association criteria was observed in 41 and 7 patients, respectively. Follow-up was performed clinically (standardized treadmill testing and color-coded Doppler ultrasound) and angiographically. The primary angiographic patency rate (24-month follow-up) was 86.8%. In 3 patients, angiography revealed significant restenoses, which were successfully treated with percutaneous transluminal angioplasty.
ConclusionsPrimary stent implantation with the kissing balloon technique is safe and effective for the treatment of aortoiliac obstructions involving the aortic bifurcation and represents a true endovascular alternative to surgery.
Key Words: angioplasty aorta claudication peripheral vascular disease stents
| Introduction |
|---|
|
|
|---|
Complex iliac artery obstructions, particularly bilateral stenoses or total iliac artery occlusions, are usually treated with aortofemoral or aortobifemoral graft surgery. Although highly effective, these surgical interventions are associated with a substantial procedure-related risk for the patient. In a meta-analysis of studies published after 1975, the aggregated operative mortality rate was 3.3%, and the aggregated systemic morbidity rate was 8.3%.8
Although the clinical introduction of endovascular stents has contributed to an expansion of indications for minimally invasive endovascular procedures,9 there is only limited experience with PTA for the treatment of bilateral iliac obstructions involving the aortic bifurcation. The potential of contralateral embolism or contralateral iliac artery occlusion due to dislodgement of atherosclerotic or thrombotic material during unilateral PTA has prevented the common use of interventional techniques in this vessel segment.
To avoid these complications, the "kissing balloon technique" was developed for bilateral simultaneous angioplasty of the common iliac arteries. Clinical experience with this technique has been reported only occasionally, and there are no documented series.10 11 12 13
The purposes of this study were to evaluate the clinical, hemodynamic, and angiographic changes after stent-supported reconstruction of the aortic bifurcation with the kissing balloon technique and to assess the long-term results of this procedure.
| Methods |
|---|
|
|
|---|
|
According to the guidelines of the American Heart Association,14 the Rutherford categories were used for clinical classification.15 The majority of patients presented with markedly impaired walking capacity due to claudication. Accordingly, preinterventional standardized treadmill testing (5 minutes at 2 mph on a 12% incline) was completed by only 2 of 48 patients (4.2%). The mean ankle-brachial index (ABI) before and after exercise was 0.53±0.14 and 0.44±0.15 on the left side and 0.51±0.16 and 0.41±0.14 on the right side, respectively. Although the majority of patients reported bilateral symptoms of claudication (n=42, 87.5%), the functional impairment was mostly asymmetric, with 1 leg being more symptomatic.
Because direct color-coded Doppler imaging of the aortic
bifurcation with cross-sectional planimetry was possible in only <50%
of the patients, indirect Doppler criteria were used, including
shape of the Doppler spectrum and maximum peak flow velocities
determined in both common femoral arteries (CFAs). Preinterventional-
and postinterventional Doppler findings are given in Table 3
.
|
The preinterventional angiography showed bilateral common iliac artery stenoses of >85% diameter reduction in 25 cases. Unilateral occlusions (mean length, 6.7±2.7 cm) and contralateral stenosis (>85%) were present in 22 patients, and bilateral occlusion was present in 1 patient. Seven patients had coexistent relevant stenosis of the infrarenal aorta. The peripheral runoff was markedly impaired in 5 patients, showing occlusions or relevant stenoses of the superficial femoral artery.
Recanalization Procedure and Stent
Implantation
The standard approach for bilateral iliac artery
stenoses was the retrograde technique. After bilateral sheath
placement (8F) on each side, an 0.018-inch guidewire (High Torque;
Mallinckrodt) was navigated through the lesion.
In the case of unilateral iliac artery occlusion, the wire loop technique was used.16 After retrograde puncture and sheath placement into the contralateral CFA, the occlusion was initially passed in crossover technique with a 0.035-inch hydrophilic guidewire (stiff type, angled tip; Terumo), finally placed into the superficial femoral artery. With the guidewire as a marker, the ipsilateral CFA was punctured under fluoroscopic control, and a second 8F sheath was placed. With an angled, shaped wire loop introduced through the ipsilateral sheath, the tip of the guidewire was snared and retrieved out of the sheath. This technique of initial contralateral passage of the occlusion minimizes the risk of subintimal tracking in the area of the aortic bifurcation. The additional steps of the procedure are performed similarly to those for stenotic lesion with a bilateral retrograde approach.
To achieve optimal debulking of the obstructed vessel, several retrograde passes were made with a multifiber laser catheter. Pulsed Excimer laser systems, working at a wavelength of 308 nm (LAIS DYMER 200+: pulse duration, 200 ns; calibrated fluence, 40 to 60 mJ/mm2; Spectranetics CVX 300: pulse duration, 200 ns; calibrated fluence, 45 mJ/mm2), were used for the generation of laser energy. Additional predilatations with undersized balloons (mean diameter, 6.2 mm; range, 5 to 7 mm) were performed in 16 of 48 patients (33.3%), always with the kissing balloon technique.
In all cases, primary implantation of Palmaz stents (P394; Johnson & Johnson Interventional Systems) was performed to stabilize the recanalized vessel segment. Balloon-mounted stents were bilaterally introduced and positioned at the aortic bifurcation extending 3 to 5 mm into the distal aorta; this allows optimal reconstruction of the aortic bifurcation. In all cases, stent implantation was performed simultaneously on both sides with the kissing balloon technique.
A total of 113 stents were implanted into the common iliac arteries.
The mean length of the stented segment was 4.8±0.82 mm (range, 3
to 12 mm). Diameters of the implanted devices were equal to the
final balloon diameter (range, 7 to 10 mm; mean, 7.8±0.61
mm). To avoid overdilatation, final balloon diameters were selected
through comparison with the distal reference segment. (See
Figure
).
|
In 7 patients with relevant aortic stenoses, stent implantation into the infrarenal aorta was performed. Stent types used in this location were Palmaz stents (P4014/P5014) in 6 patients and a Gianturco stent in 1 patient, respectively. Diameters ranged from 20 to 25 mm. Because large aortic balloons with diameters between 20 and 25 mm allow only low-pressure inflations (2 to 4 atm), in all cases, we performed simultaneous dilatations with 2 balloons (diameter, 8 to 10 mm) within the stent to achieve an optimal expansion.
Postprocedural Treatment
During intervention, all patients received 10 000 U heparin
intra-arterially, followed by 1000 to 1200 U/h heparin IV
for 24 hours (activated partial thromboplastin time, 60 to
80 s). Anticoagulation was continued with 0.3 mg
low-molecular-weight heparin SC (Fraxiparin; Sanofi Winthrop GmbH) BID
for 2 weeks. Oral anticoagulation with phenprocoumon was administered
to 3 patients. All other patients received a combination of ticlopidine
(250 mg BID for 4 weeks) and acetylsalicylic acid
(100 mg/d).
Follow-Up Protocol
Clinical follow-up examinations, including standardized
treadmill testing and color-coded duplex sonography (Sonos 1000 and
Sonos 2000 7.5-MHz linear transducer; Hewlett Packard), were performed
at hospital discharge; at 1, 3, 6, 12, and 18 months; and then yearly.
In 43 of 48 patients (89.6%) after a mean period of 18 months (range,
4 to 51 months), follow-up angiography, including
intra-arterial measurement of translesion pressure
gradient, was obtained.
Definitions
"Technical success" was defined as restored patency of the
vessel with an angiographic residual diameter stenosis of
<30% and a residual translesion pressure gradient of <5
mm Hg.
"Cumulative clinical patency rates" were calculated according to the Rutherford criteria15 on the basis of findings of the most recent available investigation. Angiographic patency at follow-up was defined as <50% diameter restenosis and a translesion pressure gradient of <5 mm Hg. "Cumulative angiographic patency rates" were calculated based on the angiographic findings, including intra-arterial pressure measurements for 43 patients who underwent follow-up angiography.
"Primary patency" refers to uninterrupted patency with no procedures performed on or at the margins of the treated segment. "Secondary patency" was defined as patency of the target vessel regardless of secondary interventions performed to restore blood flow.
Statistical Analysis
Continuous variables are presented as mean±SD
values, if appropriate. In the case of a nongaussian distribution,
median and range values are given. Patency rates were calculated with
the use of the Kaplan-Meyer life-table method. The paired t
test was used to analyze continuous data from paired
samples.
| Results |
|---|
|
|
|---|
A marked clinical improvement of +3 or +2 grades according to the limb
status grading system14 15 was achieved in 7 and 41
patients, respectively (Table 2
). Changes
in the ABI and the Doppler peak flow velocity (transcutaneous
color-coded Doppler ultrasound) before and after the intervention,
as well as the values at the most recent available follow-up, are given
in Table 3
.
|
Follow-Up Results
During the mean clinical follow-up of 24 months (median, 22
months; range, 6 to 56 months), a deterioration in the initial clinical
improvement according to American Heart Association classification was
observed in only 5 patients. Accordingly, the mean ABI before and after
treadmill exercise, as well as the Doppler peak flow velocities in
the CFA, remained almost stable during the follow-up period (Table 3
).
In 3 of 5 resymptomatic patients, the control angiography revealed significant restenoses within the stented segment. In the remaining 2 cases, de novo atherosclerotic lesions at other vessel segments (external iliac artery, n=1; superficial femoral artery, n=1) were demonstrated. All lesions could be successfully treated with secondary interventions, leading to a secondary patency rate of 100%.
Cumulative primary clinical and angiographic patency rates were
calculated on an intention-to-treat basis using the Kaplan-Meyer
life-table method and are given in Table 4
.
|
| Discussion |
|---|
|
|
|---|
In contrast, the experience with PTA for complex bilateral aortoiliac obstructions is limited and has been reported only sporadically and for small numbers of patients.10 11 12 17 Technical difficulties, such as the unavailability of suitable-sized high-pressure aortic balloons, and the relatively frequent occurrence of severe procedure-related complications, such as contralateral peripheral embolism in the case of conventional unilateral PTA, have been major drawbacks in the widespread use of interventional techniques in this location. Indeed, inflation of a single balloon in 1 common iliac artery close to the aortic bifurcation can cause compression of the contralateral artery, resulting in relatively poor dilatation and risking contralateral embolization. To overcome these problems, the kissing balloon technique was developed. In the performance of a simultaneous bilateral inflation of similar-sized balloons, the aortic bifurcation can be optimally dilated, minimizing the risk of plaque displacement and embolization. Insall et al18 reported a series of 86 kissing balloon procedures performed in 79 patients; technically successful dilatation was achieved in 94%, and symptomatic relief was obtained in 87%.
In the past decade, the implantation of endovascular stents has become a widely used adjunctive interventional technique. Especially in the iliac location, the use of these devices in the case of relevant residual stenoses yields excellent results and limits the complications of angioplasty.3 4 5 6 The potential of endovascular stents to improve the results of angioplasty at the aortic bifurcation has not yet been systematically analyzed.13 However, implantation of stents in this location may be particularly beneficial because ostia of major arterial branches such as the aortic bifurcation are prone to severe atherosclerotic changes of the vessel wall combined with extensive calcification. Several mechanisms have been proposed to account for this phenomenon. The markedly reduced cross-sectional area of the iliac vessels compared with the aorta causes an increase in blood pressureinduced arterial wall stress. Mediated by endothelial cells, smooth muscle cells, and the penetration of LDL, this may subsequently promote atherosclerosis.19 Furthermore, hemodynamic phenomena such as non-newtonian fluid rheology at the aortic bifurcation cause increased wall shear stress, which shows a positive correlation with intimal thickness.20
In the present study, 48 patients with obstructions of the aortoiliac bifurcation underwent excimer laserassisted angioplasty, followed by primary stent implantation with the kissing balloon technique.
All stents were placed, with successful restoration of the vessel patency. Because the use of conventional diagnostic angiography may underestimate hemodynamically significant residual luminal narrowing in iliac arteries, intra-arterial measurement of translesion pressure gradient was performed.21 With this hemodynamic criterion, successful stent deployment was confirmed in all cases, leading to a 100% technical success rate.
Several technical aspects should be considered to achieve an optimal technical result. In the common iliac arteries, stent and balloon diameter should be chosen through comparison with the normal distal reference segment, providing an optimal luminal gain and full expansion of the stent. The techniques of intra-aortic stent placement are more demanding than those in iliac procedures. For heavily calcified infrarenal aortic stenoses, an optimal circumferential apposition of the stent is sometimes difficult to achieve because large aortic balloons permit only a limited inflation pressure. A double-balloon technique with 2 simultaneously inflated smaller balloons (diameter, 8 to 10 mm) can be used to solve this problem. However, we always avoided overdilatation to prevent the risk of hazardous aortoiliac rupture.
The length of the stent should be chosen to completely encompass the entire lesion. This is especially critical for ostial lesions of the common iliac artery, because atherosclerotic disease usually extends into the distal aorta. To ensure optimal reconstruction of the aortic bifurcation, stents were deliberately placed in the aortic lumen somewhat beyond the assumed bifurcation.13 Furthermore, this technique may contribute to a reduction in embolic complications, because dislodgment of thrombotic material or plaque displacement may be prevented with the stent struts.
With regard to stent types, we almost exclusively used the Palmaz stent for implantation at the aortic bifurcation. This stent has some favorable mechanical properties for application in ostial lesions and in the relatively straight common iliac arteries, where flexibility of the stent seems to be of relatively little importance. Constructed as a plastically deformable latticework, it can particularly well resist the relatively high reconfiguration forces of fibrotic, calcified, or highly excentric iliac stenoses. Furthermore, because the stent opens out with only minimal shortening, extremely exact placement in the aortoiliac orifice is ensured.3 4 9
Early series of percutaneous recanalization procedures for chronic iliac artery occlusions demonstrated poor results and excessively high complication rates of up to 20%.2 17 22 More recently, larger studies have produced encouraging results. Johnston et al2 achieved a considerable primary recanalization rate of 82% (67 of 82 patients were treated successfully), but the cumulative patency rate after a mean follow-up of 36 months was only 58%. Vorwerk et al23 demonstrated that endovascular stents significantly contribute to an improvement in the long-term results. In a series of 103 patients with chronic iliac artery occlusions, the authors performed primary stent placement and achieved a primary 2-year patency rate of 83% and a 4-year patency rate of 78%. Vorwerk et al23 reported that one major reason for technical failure of retrograde iliac recanalization was subintimal passage of the occlusion with an excentric reentry through the aortic wall. To avoid this complication, we performed all recanalization procedures of iliac occlusions in crossover technique using the "wire loop technique."16 By using this approach, we were successful in crossing all 22 common iliac occlusions without complications.
After the initial guidewire passage of an iliac artery occlusion, effective removal of obstructing atherosclerotic and thrombotic material must be achieved. Local thrombolytic therapy before PTA has been advocated, especially for fresh iliac artery thromboses24 ; however, it has not been proved to be universally effective for chronic occlusions.25 In our study, photoablation of atherosclerotic material through the performance of several passes with an excimer laser multifiber catheter (diameter, 2.2 to 2.5 mm) has been used to create a primary laser canal of 2 to 3 mm in diameter. In this way, subsequent balloon dilatation and stent implantation have been facilitated, substantially reducing the risk of distal embolization.
Long-term results are based on clinical, angiographic, and hemodynamic findings. Clinical patency was evaluated indirectly through the retention of clinical benefits, measured with the limb status grading system. Of 48 patients, 43 showed no deterioration in the initial clinical improvement, accounting for a 85.3% clinical patency rate after 24 months. However, these clinical criteria reflect the state of vessel patency for the entire extremity. To evaluate the long-term results of the aortoiliac reconstruction, angiography combined with intra-arterial measurement of the translesion pressure gradient was obtained in 43 of 48 patients (89.6%), including all cases with recurrent clinical symptoms. In only 3 patients was there evidence of relevant in-stent restenosis, accounting for a cumulative primary angiographic patency rate of 97.2% after 12 months and of 86.8% after 24 months. Because all restenotic lesions could be successfully retreated with balloon angioplasty, a secondary angiographic and clinical patency rate of 100% could be achieved.
In summary, the results of the present study demonstrate that stent-supported reconstruction of the aortoiliac bifurcation is a safe and highly effective interventional technique. Even very complex obstructions with unilateral iliac occlusion, contralateral high-grade stenosis, and coexistent infrarenal aortic stenosis can be treated, achieving a high technical success rate. The long-term results with the use of primary stent implantation at the aortic bifurcation are similar to the data reported for the use of short segment iliac artery stents. According to the low complication rate and the excellent technical and follow-up results, this technique may be considered as a first-line treatment for patients with symptomatic atherosclerotic occlusive disease at the aortic bifurcation. However, further investigation should be focused on the 5- and 10-year patency rates in comparison with the surgical results.
| References |
|---|
|
|
|---|
2.
Johnston KW. Iliac arteries: reanalysis of
results of balloon angioplasty. Radiology. 1993;186:207212.
3. Murphy KD, Encarnacion CE, Le VA, Palmaz JC. Iliac artery stent placement with the Palmaz stent: follow-up study. J Vasc Intervent Radiol. 1995;6:321329.[Medline] [Order article via Infotrieve]
4.
Henry M, Amor M, Ethevenot G, Henry I, Amicabile C,
Beron R, Mentre B, Allaoui M, Touchot N. Palmaz stent placement in
iliac and femoropopliteal arteries: primary and secondary patency in
310 patients with 24 year follow-up. Radiology. 1995;197:167174.
5. Sullivan TM, Childs MB, Bacharach JM, Gray BH, Piedmonte MR. Percutaneous transluminal angioplasty and primary stenting of the iliac arteries in 288 patients. J Vasc Surg. 1997;25:829838.[Medline] [Order article via Infotrieve]
6.
Vorwerk D, Günther RW, Schürmann K, Wendt
G. Aortic and iliac stenoses: follow-up results of stent
placement after insufficient balloon angioplasty in 118 cases.
Radiology. 1996;198:4548.
7. Brothers TE, Greefield LJ. Long-term results of aortoiliac reconstruction. J Vasc Intervent Radiol. 1990;1:4955.[Medline] [Order article via Infotrieve]
8. de Vries SO, Hunink MGM. Results of aortic bifurcation grafts for aortoiliac occlusive disease: a meta-analysis. J Vasc Surg. 1997;26:558569.[Medline] [Order article via Infotrieve]
9. Becker GJ. Intravascular stents: general principles and status of lower-extremity arterial applications. Circulation. 1991;83(suppl I):I-122I-136.
10.
Velasquez G, Castaneda-Zuniga W, Formanek A.
Non-surgical aortoplasty in Leriche syndrome. Radiology. 1980;134:359360.
11. Tegtmeyer CJ, Wellons HA, Thompson RN. Balloon dilatation of the abdominal aorta. JAMA. 1980;244:26262637.
12. Morag G, Rubinstein Z, Kessler A, Schneiderman J, Levinkopf M, Bass A. Percutaneous transluminal angioplasty of the distal abdominal aorta and its bifurcation. Cardiovasc Intervent Radiol. 1987;10:129133.[Medline] [Order article via Infotrieve]
13. Küffer G, Spengel F, Steckmeier B. Percutaneous reconstruction of the aortic bifurcation with Palmaz stents: case report. Cardiovasc Intervent Radiol. 1991;14:170172.[Medline] [Order article via Infotrieve]
14.
Pentecost MJ, Criqui MH, Dorros G, Goldstone J,
Johnston KW, Martin EC, Ring EJ, Spies JB. Guidelines for
peripheral percutaneous transluminal
angioplasty of the abdominal aorta and lower extremity vessels.
Circulation. 1994;89:511531.
15. Rutherford RB. Standards for evaluating results of interventional therapy for peripheral vascular disease. Circulation. 1991;83(suppl I):I-6I-11.
16.
Gaines PA, Cumberland DC. Wire loop technique for
angioplasty of total iliac artery occlusions. Radiology. 1988;168:275276.
17.
Colapinto RF, Stronell RD, Johnston WK. Transluminal
angioplasty of complete iliac obstructions. Am J
Roentgenol. 1986;146:859862.
18. Insall RL, Loose HWC, Chamberlain J. Long-term results of double-balloon percutaneous transluminal angioplasty of the aorta and iliac arteries. Eur J Vasc Surg. 1993;7:3136.[Medline] [Order article via Infotrieve]
19.
Thubrikar MJ, Robicsek F. Pressure-induced
arterial wall stress and atherosclerosis.
Ann Thorac Surg. 1995;59:15941603.
20. Hayashi K, Yanai Y, Naiki T. A 3D-LDA study of the relation between wall shear stress and intimal thickness in a human aortic bifurcation. J Biomech Eng. 1996;118:273279.[Medline] [Order article via Infotrieve]
21.
Tetteroo E, van Engelen AD, Spithoven JH, Tielbeek AV,
van der Graaf Y, Mali WP. Stent placement after iliac angioplasty:
comparison of hemodynamic and angiographic criteria:
Dutch Iliac Stent Trial Study Group. Radiology. 1996;201:155159.
22.
Ring EJ, Freimann DB, McLean GK, Schwarz W.
Percutaneous recanalization of
common iliac artery occlusions: an unacceptable complication rate?
AJR Am J Roentgenol. 1982;139:587589.
23.
Vorwerk D, Guenther RW, Schürmann K, Wendt G,
Peters I. Primary stent placement for chronic iliac artery occlusions:
follow-up results in 103 patients. Radiology. 1995;194:745749.
24.
Blum U, Gabelmann A, Redecker M, Noldge G, Dornberg W,
Grosser G, Heiss W, Langer M. Percutaneous
recanalization of iliac artery occlusions: results
of a prospective study. Radiology. 1993;189:536540.
25. Hausegger KA, Lammer J, Klein G, Fluckiger F, Lafer M, Pilger E, Aschauer M. Percutaneous recanalization of pelvic artery occlusionsfibrinolysis, PTA, stents. Fortschr Rontgenstr. 1991;155:550555.
| |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
|
Circulation Home | Subscriptions | Archives | Feedback | Authors | Help | AHA Journals Home | Search Copyright © 1999 American Heart Association, Inc. All rights reserved. Unauthorized use prohibited. |