Donate Help Contact The AHA Sign In Home
American Heart Association
Circulation
Search: search_blue_button Advanced Search
Circulation. 1999;100:768-771

This Article
Right arrow Abstract Freely available
Right arrow Full Text (PDF)
Right arrow Alert me when this article is cited
Right arrow Alert me if a correction is posted
Right arrow Citation Map
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Download to citation manager
Right arrow Request Permissions
Citing Articles
Right arrow Citing Articles via HighWire
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Tsai, C.-F.
Right arrow Articles by Chen, S.-A.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Tsai, C.-F.
Right arrow Articles by Chen, S.-A.
Related Collections
Right arrow Arrythmias-basic studies
Right arrow Ablation/ICD/surgery

(Circulation. 1999;100:768-771.)
© 1999 American Heart Association, Inc.


Basic Science Reports

Is 8-mm More Effective Than 4-mm Tip Electrode Catheter for Ablation of Typical Atrial Flutter?

Presented at the 71st Scientific Sessions of the American Heart Association, Dallas, Tex, November 8–11, 1998, and published in abstract form (Circulation. 1998;98[suppl 1]: I-19.)

Chin-Feng Tsai, MD; Ching-Tai Tai, MD; Wen-Chung Yu, MD; Yi-Jen Chen, MD; Ming-Hsiung Hsieh, MD; Chern-En Chiang, MD; Yu-An Ding, MD; Mau-Song Chang, MD; Shih-Ann Chen, MD

From the Division of Cardiology, Department of Medicine, National Yang-Ming University, School of Medicine, and Veterans General Hospital-Taipei and Division of Cardiology, Department of Medicine, Chung Shan Medical and Dental College Hospital (C.-F.T.), Taiwan, R.O.C.

Correspondence to Shih-Ann Chen, MD, Division of Cardiology, Veterans General Hospital-Taipei, 201, Sec 2, Shih-Pai Road, Taipei, Taiwan, R.O.C. E-mail sachen{at}vghtpe.gov.tw


*    Abstract
up arrowTop
*Abstract
down arrowIntroduction
down arrowMethods
down arrowResults
down arrowDiscussion
down arrowReferences
 
Background—The prospective, randomized study comparing 4- with 8-mm tip electrodes for radiofrequency linear ablation of typical atrial flutter is not available.

Methods and Results—A total of 104 consecutive patients with typical atrial flutter were randomly assigned to undergo radiofrequency linear ablation using a 4- (Group I, n=54) or 8-mm tip electrode (Group II, n=50) catheter (temperature-control model, preset 70°C). If complete bidirectional isthmus block could not be achieved after 5 pulses, the ablation catheter was changed to the other type; the maximal radiofrequency pulse number was limited to <10 pulses. Complete or incomplete isthmus conduction block was assessed by activation sequence in a multielectrode Halo catheter during low lateral right atrial and proximal coronary sinus pacing. Before shifting to the other catheter type, the 8-mm electrode catheter achieved higher complete isthmus block rate (92% versus 67%, P<0.05) with fewer pulses (2±1 versus 3±1, P<0.05), shorter procedure time (24±15 versus 31±12 minutes, P<0.05), and shorter fluoroscopic time (14±10 versus 23±15 minutes, P<0.05). After 5 failed ablation pulses, 12 (67%) of 18 patients in group I attained complete isthmus block by using an 8-mm tip catheter, but none of 4 patients in group II achieved complete block by changing to a 4-mm tip catheter.

Conclusions—The 8-mm tip electrodes are more effective than the standard 4-mm length electrodes in linear ablation for typical atrial flutter. This clinical benefit may be of particular value for some patients with broad and/or thick isthmus.


Key Words: atrial flutter • ablation • isthmus


*    Introduction
up arrowTop
up arrowAbstract
*Introduction
down arrowMethods
down arrowResults
down arrowDiscussion
down arrowReferences
 
Typical atrial flutter (AF) has been proved to be a macroreentrant circuit in the right atrium.1 2 Radiofrequency (RF) linear ablation targeting the cavotricuspid isthmus can achieve a high success rate.3 4 5 6 Bidirectional isthmus conduction block appears to be a better ablation end point, as opposed to interruption and noninducibility of AF.7 8 9 Previous experimental studies have shown that an 8- to 10-mm tip electrode is superior to the standard 4-mm tip electrode in ablation effects on ventricular tissues, applying higher RF power and causing a further increase in lesion size and depth.10 11 12 However, a randomized study comparing 4- with 8-mm tip electrodes for linear ablation of AF was not available. Thus, this study compared the effects of ablation on typical AF using a large tip catheter (7F, 8 mm) with those of a conventional ablation catheter (7F, 4 mm) in a prospective randomized fashion among a large patient group.


*    Methods
up arrowTop
up arrowAbstract
up arrowIntroduction
*Methods
down arrowResults
down arrowDiscussion
down arrowReferences
 
Study Patients
The study included 104 consecutive patients (76 males, 28 females; mean age 63±10 years) referred to this institution for ablation of typical AF. All patients were intolerant or had recurrent AF despite a mean of 3±1 antiarrhythmic drugs before referral. Sixty-two patients had associated cardiopulmonary diseases, including hypertensive heart diseases (n=30), coronary artery disease (n=9), valvular heart disease (n=8), and chronic lung disease (n=15). Left or right atrial enlargement was considered to be present if the end-systolic midcavity mediolateral dimension exceeded 4.5 cm on 2-D and M-mode echocardiography.9

Radiofrequency Ablation
The methods of electrophysiological studies and ablation of AF in this laboratory have been described previously.6 9 All clinically documented AF was induced by programmed stimulation protocols established in most laboratories.3 4 5 6 7 8

In all patients, a deflectable duodecapolar Halo catheter (Cordis-Webster, Inc) was used to demonstrate an AF exhibiting either a counterclockwise or a clockwise activation around the tricuspid annulus and through the low right atrium isthmus. All electrograms, filtered between 30 and 500 Hz, were recorded with a commercial digital acquisition system (Prucka Engineering, Inc). All patients were randomly assigned to undergo transisthmus linear ablation using a 4- (Group I, n=54) or an 8-mm tip electrode (Group II, n=50) catheter initially. The clinical characteristics were similar between both groups (Table 1Down). RF energy was delivered by a generator (EPT-1000, EP Technologies, Inc), using a thermistor ablation catheter with a 4- or 8-mm tip electrode (7F, EP Technologies, Inc), to achieve a tip-tissue interface temperature of 70°C and an output of up to 100 W during AF or sinus rhythm (with pacing from the proximal coronary sinus if AF was not induced). The preset duration of each RF pulse was 120 seconds. By utilizing a special long venous sheath (SR0 curve, Daig) to increase stability, continuous application of RF energy during pull-back of the ablation catheter from the right ventricle toward the inferior vena cava was used to create linear lesions in the cavotricuspid isthmus. The 8-mm tip electrode catheter was not used for linear ablation of medial (septal) isthmus in close proximity to right posteroseptal area to avoid the potential risk of atrioventricular block. If complete isthmus conduction block could not be achieved after 5 pulses, the ablation catheter was replaced with the other type (Group IA: 4-mm tip electrode with successful ablation within 5 RF pulses; Group IB: 4-mm->8-mm tip electrode; Group IIA: 8-mm tip electrode with successful ablation within 5 RF pulses; Group IIB: 8-mm->4-mm tip electrodes). For comparison of group I and group II, a maximal RF pulse number was limited to 10 pulses. Successful ablation was defined as achievement of bidirectional isthmus conduction block and inability to reinduce typical AF. Complete isthmus conduction block was defined as low lateral right atrium pacing demonstrating counterclockwise conduction to the point of block followed by the delayed arrival of septal activation up to the line of block from the opposite direction; the similar activation pattern in opposite direction was demonstrated with proximal coronary sinus pacing.7 9 Incomplete isthmus conduction block was defined as existence of any residual isthmus conduction when pacing from either side of the line of block in the cavotricuspid isthmus, irrespective of reinducibility of AF.


View this table:
[in this window]
[in a new window]
 
Table 1. Clinical Characteristics of Study Patients

Post-Ablation Follow-Up
All patients received 24-hour Holter monitoring 1 day before hospital discharge. Follow-up examination was performed at 2 weeks, 1 month, and 3 months after ablation with complete history taken, physical examination, and a 12-lead ECG. When patients experienced symptoms suggestive of tachycardia, 24-hour Holter monitoring, cardiac events recording, or a follow-up electrophysiological study was performed to define the cause of tachycardia. RF ablation was repeated if recurrent typical AF was documented. Long-term follow-up information was also obtained from the referring physicians and through telephone interviews with the patients.

Statistical Analysis
Quantitative data were expressed as mean±SD and compared by Student's t test. Categorical data were analyzed by the {chi}2 test with Yates' correction or Fisher's exact test. P<0.05 was considered statistically significant.


*    Results
up arrowTop
up arrowAbstract
up arrowIntroduction
up arrowMethods
*Results
down arrowDiscussion
down arrowReferences
 
Comparison of Effects of Radiofrequency Ablation
Within the first 5 ablation attempts, complete isthmus conduction block was demonstrated in 36 of 54 (67%) Group I patients and 46 of 50 (92%) Group II patients (Table 2Down). Among the 18 patients in Group IB, complete isthmus block was achieved in 12 (67%) patients after changing to an 8-mm tip electrode catheter. In none of Group IIB patients could complete isthmus conduction block be attained, yet in all these incomplete isthmus block cases, sustained AF was no longer induced after ablation. In a comparison of ablation results between Group I and Group II, 8-mm tip electrode catheters had a higher successful ablation rate than 4-mm tip catheters (8- versus 4-mm: 92% versus 67%, P<0.05) with a lower mean number of application pulses (2±1 versus 3±1, P<0.05), shorter mean procedure time (24±15 minutes versus 31±12 minutes, P<0.05), and shorter mean fluoroscopic time (14±10 minutes versus 23±15 minutes, P<0.05) required for creation of complete isthmus conduction block. There were no complications related to the ablation procedure in any patient.


View this table:
[in this window]
[in a new window]
 
Table 2. Results of Radiofrequency Linear Ablation

Follow-Up
During a mean follow-up of 10±5 months (range, 6 to 15 months), patients with incomplete isthmus block had a significantly higher incidence of recurrent AF than those with complete isthmus block (5 of 10 versus 0 of 94, P<0.0001). In all 5 patients with recurrent AF, repeated electrophysiological study revealed recovery of intact isthmus conduction: 1 received amiodarone therapy and the other 4 underwent a second successful ablation session. The incidence of clinically documented atrial fibrillation at follow-up periods was 22% (23 of 104) and was not significantly different in both groups. This finding suggested that the occurrence of atrial fibrillation may not be related to the ablation-induced lesions.


*    Discussion
up arrowTop
up arrowAbstract
up arrowIntroduction
up arrowMethods
up arrowResults
*Discussion
down arrowReferences
 
Major Findings
To our knowledge, this is the first prospective randomized study to compare the effects of large (8-mm) and conventional tip electrode (4-mm) catheters on ablation for typical AF. This study demonstrated that an 8-mm tip electrode catheter could facilitate RF linear ablation of typical AF by achieving a higher success rate with a lower pulse number, shorter procedure, and less radiation exposure time required for creation of complete bidirectional isthmus conduction block.

Effects of a Large Tip Electrode on Radiofrequency Lesion
Previous experimental studies have shown that increase in ablation electrode size can allow the application of higher RF power, resulting in a further increase in lesion size and depth.10 11 12 McRury et al demonstrated good correlation between electrode size and temperature with lesion size in temperature-controlled RF ablation model in canine ventricles.12 Langberg et al also showed that the larger electrode could couple higher power and less impedance rise to achieve the preset target temperature.11 In this study, the superiority of the 8-mm tip electrode might rely on a larger and deeper lesion created by 2 mechanisms.13 First, a larger tip electrode with a larger electrode-blood interface area, in particular under high blood flow in the cavotricuspid isthmus area, could increase the convective cooling effect and allow higher RF power delivery to the tissues at the same electrode-tissue interface temperature with resulting greater depth of direct resistive heating. Secondly, increasing electrode-tissue interface area by orienting the electrode as parallel to the tissue as possible during the dragging ablation technique could produce greater width of direct resistive heating. Thus, both increased cooling and increased electrode-tissue interface area with a large tip electrode increase volume of direct resistive heating and create a larger and deeper lesion. Langberg et al showed that thermistor-equipped elongated ablation electrodes (8-mm) coupled to high-power outputs could reproducibly produce lesions approximately 1 cm in diameter and 11 mm in depth.11 In this study, we used a temperature feedback power control (up to 100 W) at a target temperature of 70°C. Accordingly, the 8-mm tip electrode catheter is superior to the 4-mm tip catheter with respect to energy delivery parameters for a steady-state temperature to make a larger and deeper lesion.

Some AF cases demonstrating resistance to or difficulty with RF ablation may be due to a broader or thicker than usual isthmus or to complex isthmus architecture with resulting in adaptation of catheters. Tabuchi et al studied isthmus pathology after RF ablation for the canine AF and demonstrated the requirement of transmural damage of the atrial myocardium from the endocardium to the subepicardium for successful isthmus ablation.14 Therefore, using an 8-mm tip electrode catheter (supported by a long vascular sheath for a consistent good contact with endocardial surface and for making continuous lesions during steadily dragging catheter) might be of particular benefit in linear ablation of broad and/or thickened isthmus by producing adequate lesion size and depth to reduce the possibility of skip lesions (gaps) formation.

Comparison With Previous Studies
Feld et al used the electrophysiological approach for AF ablation and compared the efficacy between 8- and 4-mm tip catheter. They showed reductions of the mean number of energy applications (from 11 to 6 pulses) and recurrence rate (from 43% to 10%) by using 8-mm tip electrode catheters.15 Iesaka et al used the anatomical approach for ablation of AF by using an 8-mm tip electrode and used the electrophysiological approach for ablation of AF by using a 4-mm tip electrode. They also concluded that the 8-mm tip electrode reduced the number of energy applications (from 10 to 2.3 pulses) required for successful ablation.16 In these 2 studies, there were some confounding issues on validity of results with regard to different ablation approach methods (anatomic versus electrophysiolgical approach) and ablation end points (termination and noninducibility versus isthmus conduction block). Additionally, these studies were not randomized controlled studies. Our laboratory had reported that the anatomic approach was time-saving with respect to the procedure time and radiation exposure time compared with electrophysiologically guided focal ablation.6 Additionally, this study used a randomized prospective method to compare the efficacy of different electrode tip sizes on ablation of AF by the anatomical approach. Thus, this study adds further insight into the superiority of 8-mm tip electrode to 4-mm tip electrode for transisthmus linear ablation of typical AF.

Clinical Implications
This study's results established clearly that 8-mm tip electrodes are more effective and as safe as the standard 4-mm length electrodes in transisthmus linear ablation for typical AF. This clinical benefit of the 8-mm tip catheter for AF ablation may be of particular value for some patients with broad and/or thick isthmus.


*    Acknowledgments
 
This study was supported in part by grants from the National Science Council (NSC-88-2314-B-010-094; 88-2314-B-010-093) and the Tzou's Foundation (VGH-23, VGH-47, VGH-61, VGH-254, VGH-301), Taipei, Taiwan.

Received January 19, 1999; revision received April 9, 1999; accepted April 15, 1999.


*    References
up arrowTop
up arrowAbstract
up arrowIntroduction
up arrowMethods
up arrowResults
up arrowDiscussion
*References
 

  1. Klein GJ, Guiraudon GM, Sharma AD, Milstein S. Demonstration of macroreentry and feasibility of operative therapy in the common type of atrial flutter. Am J Cardiol. 1986;57:587–591.[Medline] [Order article via Infotrieve]
  2. Kalman JM, Olgin JE, Saxon LA, Fisher WG, Lee RJ, Lesh MD. Activation and entrainment mapping defines the tricuspid annulus as the anterior barrier in typical atrial flutter. Circulation. 1996;94:398–406.[Abstract/Free Full Text]
  3. Cosio FG, Lopez GM, Goicolea A, Arribas F, Barroso JL. Radiofrequency ablation of the inferior vena cava-tricuspid valve isthmus in common atrial flutter. Am J Cardiol. 1993;71:705–709.[Medline] [Order article via Infotrieve]
  4. Kirkorian G, Moncada E, Chevalier P, Canu G, Claudel JP, Bellon C, Lyon L, Touboul P. Radiofrequency ablation of atrial flutter. Efficacy of an anatomically guided approach. Circualtion. 1994;90:2804–2814.[Abstract/Free Full Text]
  5. Lesh MD, Van Hare GF, Epstein LM, Fitzpatrick AP, Scheinman MM, Lee RJ, Kwasman MA, Grogin HR, Griffin JC. Radiofrequency catheter ablation of atrial arrhythmias: results and mechanisms. Circulation. 1994;89:1074–1089.[Abstract/Free Full Text]
  6. Chen SA, Chiang CE, Wu TJ, Tai CT, Lee SH, Cheng CC, Chiou CW, Ueng KC, Wen CZ, Chang MS. Radiofrequency catheter ablation of common atrial flutter—comparisons between electrophysiologically guided focal ablation technique and linear ablation technique. J Am Coll Cardiol. 1996;27:860–868.[Abstract]
  7. Poty H, Saoudi N, Abdel AA, Nair M, Letac B. Radiofrequency catheter ablation of type I atrial flutter. Prediction of late success by electrophysiological criteria. Circulation. 1995;92:1389–1392.[Abstract/Free Full Text]
  8. Cauchemez B, Haissaguerre M, Fischer B, Thomas O, Clementy J, Coumel P. Electrophysiological effects of catheter ablation of inferior vena cava-tricuspid annulus isthmus in common atrial flutter. Circulation. 1996;93:284–294.[Abstract/Free Full Text]
  9. Tai CT, Chen SA, Chiang CE, Lee SH, Wen ZC, Huang JL, Chen YJ, Yu WC, Feng AN, Lin YJ, Ding YA, Chang MS. Long-term outcome of radiofrequency catheter ablation for typical atrial flutter: risk prediction of recurrent arrhythmias. J Cardiovasc Electrophysiol. 1998;9:115–121.[Medline] [Order article via Infotrieve]
  10. Langberg JJ, Lee MA, Chin MC, Rosenqvist M. Radiofrequency catheter ablation: the effect of electrode size on lesion volume in vivo. Pacing Clin Electrophysiol. 1990;13:1242–1248.[Medline] [Order article via Infotrieve]
  11. Langberg JJ, Gallagher M, Strickberger A, Amirana O. Temperature-guided radiofrequency catheter ablation with very large distal electrodes. Circulation. 1993;88:245–249.[Abstract/Free Full Text]
  12. McRury ID, Whayne JG, Mitchell M, Haines DE. Electrode size and temperature effects on lesion volume during temperature-controlled RF ablation in vivo. J Am Coll Cardiol. 1996;27:123A. Abstract.
  13. Otomo K, Yamanashi WS, Tondo C, Antz M, Bussey J, Pitha JV, Arruda M, Nakagawa H, Wittkampf FHM, Lazzara R, Jackman WM. Why a large tip electrode makes a deeper radiofrequency lesion: effects of increase in electrode cooling and electrode-tissue interface area. J Cardiovasc Electrophsiol. 1998;9:47–54.
  14. Tabuchi T, Okumura K, Matsunaga T, Tsunoda R, Jougasaki M, Yasue H. Linear ablation of the isthmus between the inferior vena cava and tricuspid annulus for the treatment of atrial flutter. A study in the canine atrial flutter model. Circulation. 1995;92:1312–1319.[Abstract/Free Full Text]
  15. Feld G, Fujimura O, Green U, Mazzola F. Radiofrequency catheter ablation of human type 1 atrial flutter—comparison of results with 8 mm versus 4 mm tip ablation catheter. J Am Coll Cardiol. 1995;25:169A. Abstract.
  16. Iesaka Y, Takahashi A, Goya M, Yamane T, Tokunaga T, Amemiya H, Fujiwara H, Nitta J, Nogami A, Aonuma K, Hiroe M, Marumo F, Hiraoka M. High energy radiofrequency catheter ablation for common atrial flutter targeting the isthmus between the inferior vena cava and tricuspid valve annulus using a super long tip electrode. PACE. 1998;21:401–409.



This article has been cited by other articles:


Home page
Card Surg AdultHome page
R. E. Eckart and L. M. Epstein
Interventional Therapy for Atrial and Ventricular Arrhythmias
Card. Surg. Adult, January 1, 2008; 3(2008): 1357 - 1374.
[Full Text]


Home page
JAMAHome page
J. E. Marine
Catheter Ablation Therapy for Supraventricular Arrhythmias
JAMA, December 19, 2007; 298(23): 2768 - 2778.
[Abstract] [Full Text] [PDF]


Home page
EuropaceHome page
H. Calkins, J. Brugada, D. L. Packer, R. Cappato, S.-A. Chen, H. J.G. Crijns, R. J. Damiano Jr, D. W. Davies, D. E. Haines, M. Haissaguerre, et al.
HRS/EHRA/ECAS Expert Consensus Statement on Catheter and Surgical Ablation of Atrial Fibrillation: Recommendations for Personnel, Policy, Procedures and Follow-Up: A report of the Heart Rhythm Society (HRS) Task Force on Catheter and Surgical Ablation of Atrial Fibrillation Developed in partnership with the European Heart Rhythm Association (EHRA) and the European Cardiac Arrhythmia Society (ECAS); in collaboration with the American College of Cardiology (ACC), American Heart Association (AHA), and the Society of Thoracic Surgeons (STS). Endorsed and Approved by the governing bodies of the American College of Cardiology, the American Heart Association, the European Cardiac Arrhythmia Society, the European Heart Rhythm Association, the Society of Thoracic Surgeons, and the Heart Rhythm Society.
Europace, June 1, 2007; 9(6): 335 - 379.
[Full Text] [PDF]


Home page
HeartHome page
F G Cosio
Should ablation be the first line treatment for supraventricular arrhythmias?
Heart, January 1, 2005; 91(1): 5 - 6.
[Abstract] [Full Text] [PDF]


Home page
EuropaceHome page
R. J. Hillock, I. C. Melton, and I. G. Crozier
Radiofrequency ablation for common atrial flutter using an 8-mm tip catheter and up to 150 W
Europace, January 1, 2005; 7(5): 409 - 412.
[Abstract] [Full Text] [PDF]


Home page
CirculationHome page
A. Da Costa, E. Faure, J. Thevenin, M. Messier, S. Bernard, K. Abdel, C. Robin, C. Romeyer, and K. Isaaz
Effect of Isthmus Anatomy and Ablation Catheter on Radiofrequency Catheter Ablation of the Cavotricuspid Isthmus
Circulation, August 31, 2004; 110(9): 1030 - 1035.
[Abstract] [Full Text] [PDF]


Home page
Eur Heart JHome page
C. Scavee, P. Jais, L.-F. Hsu, P. Sanders, M. Hocini, R. Weerasooriya, L. Macle, F. Raybaud, J. Clementy, and M. Haissaguerre
Prospective randomised comparison of irrigated-tip and large-tip catheter ablation of cavotricuspid isthmus-dependent atrial flutter
Eur. Heart J., June 1, 2004; 25(11): 963 - 969.
[Abstract] [Full Text] [PDF]


Home page
J Am Coll CardiolHome page
G. Feld, M. Wharton, V. Plumb, E. Daoud, T. Friehling, L. Epstein, and EPT-1000 XP Cardiac Ablation System Investigators
Radiofrequency catheter ablation of type 1 atrial flutter using large-tip 8- or 10-mm electrode catheters and a high-output radiofrequency energy generator: Results of a multicenter safety and efficacy study
J. Am. Coll. Cardiol., April 21, 2004; 43(8): 1466 - 1472.
[Abstract] [Full Text] [PDF]


Home page
Card Surg AdultHome page
S. D. Satti and L. M. Epstein
Cardiologic Interventional Therapy for Atrial and Ventricular Arrhythmias
Card. Surg. Adult, January 1, 2003; 2(2003): 1253 - 1270.
[Full Text]


Home page
J Am Coll CardiolHome page
G. Stabile, A. De Simone, P. Turco, V. La Rocca, P. Nocerino, C. Astarita, F. Maresca, C. De Matteis, T. Di Napoli, E. Stabile, et al.
Response to flecainide infusion predicts long-term success of hybrid pharmacologic and ablation therapy in patients with atrial fibrillation
J. Am. Coll. Cardiol., May 1, 2001; 37(6): 1639 - 1644.
[Abstract] [Full Text] [PDF]


Home page
CirculationHome page
H. Kottkamp, B. Hugl, B. Krauss, U. Wetzel, A. Fleck, G. Schuler, and G. Hindricks
Electromagnetic Versus Fluoroscopic Mapping of the Inferior Isthmus for Ablation of Typical Atrial Flutter : A Prospective Randomized Study
Circulation, October 24, 2000; 102(17): 2082 - 2086.
[Abstract] [Full Text] [PDF]


This Article
Right arrow Abstract Freely available
Right arrow Full Text (PDF)
Right arrow Alert me when this article is cited
Right arrow Alert me if a correction is posted
Right arrow Citation Map
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Download to citation manager
Right arrow Request Permissions
Citing Articles
Right arrow Citing Articles via HighWire
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Tsai, C.-F.
Right arrow Articles by Chen, S.-A.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Tsai, C.-F.
Right arrow Articles by Chen, S.-A.
Related Collections
Right arrow Arrythmias-basic studies
Right arrow Ablation/ICD/surgery