Donate Help Contact The AHA Sign In Home
American Heart Association
Circulation
Search: search_blue_button Advanced Search
Circulation. 2006;114:1745-1754
doi: 10.1161/CIRCULATIONAHA.106.646190
Free Article
This Article
Free upon publication Free Article
Right arrow Full Text
Right arrow Full Text (PDF)
Right arrow Alert me when this article is cited
Right arrow Alert me if a correction is posted
Right arrow Citation Map
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Download to citation manager
Right arrowRequest Permissions
Citing Articles
Right arrow Citing Articles via HighWire
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Eisenberg, M. J.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Eisenberg, M. J.
Related Collections
Right arrow Health policy and outcome research
Right arrow Restenosis
Right arrow Catheter-based coronary interventions: stents
Right arrow Angioplasty and Stenting
Right arrow Coronary circulation

(Circulation. 2006;114:1745-1754.)
© 2006 American Heart Association, Inc.


Controversies in Cardiovascular Medicine

Drug-Eluting Stents

The Price Is Not Right

Mark J. Eisenberg, MD, MPH

From the Divisions of Cardiology and Clinical Epidemiology, Jewish General Hospital/McGill University, Montreal, Quebec, Canada.

Correspondence to Mark J. Eisenberg, MD, MPH, Associate Professor of Medicine, Divisions of Cardiology and Clinical Epidemiology, Jewish General Hospital/McGill University, 3755 Cote Ste Catherine Rd, Suite A-118, Montreal, Quebec, Canada H3T 1E2. E-mail meisenberg@epid.jgh.mcgill.ca


An extract of the first 250 words of the full text is provided, because this article has no abstract.
 


*    Introduction
 

"Does it make economic sense to completely abandon a therapy that works well for 85% to 90% of the population for a new therapy costing four times as much to treat a transient health condition with no impact on either death or myocardial infarction?"

J.M. Brophy and L.J. Erickson1

Since Andreas Gruntzig performed the first percutaneous coronary intervention (PCI) in 1977,2 the cost-effectiveness of this procedure has engendered major controversy. Debates have erupted over the clinical value and cost-effectiveness of each new device or therapy that has become available. Controversies have arisen regarding the cost of atherectomy, bare metal stents (BMS), brachytherapy, distal protection devices, glycoprotein IIb/IIIa inhibitors, and intravascular ultrasound.3–6 Drug-eluting stents (DES) are the most recent devices to have their cost scrutinized.7–12

Response by Ryan and Cohen p 1754


*    Clinical Effectiveness and DES Penetration
 
Balloon angioplasty is associated with restenosis rates of 30% to 40%, whereas PCI with BMS is associated with rates of 20% to 30%,13,14 and PCI with DES is associated with rates in the single digits.15,16 My colleagues and I pooled the results of 11 DES trials involving >5000 patients using a hierarchical Bayesian random-effects model.17 We found that, compared with BMS, DES reduce angiographic restenosis from 29.3% to 8.9% (Table 1 and Figure 1). There was no difference between DES and BMS in terms of mortality (0.9% versus 0.9%, respectively) or myocardial infarction (2.7% versus 2.9%, respectively). There was a suggestion that restenosis was less with sirolimus-eluting stents (SES) compared with polymeric paclitaxel-eluting stents (PES) (6.2% for . . . [Full Text of this Article]




This article has been cited by other articles:


Home page
CirculationHome page
J. Ryan, W. Linde-Zwirble, L. Engelhart, L. Cooper, and D. J. Cohen
Temporal Changes in Coronary Revascularization Procedures, Outcomes, and Costs in the Bare-Metal Stent and Drug-Eluting Stent Eras: Results From the US Medicare Program
Circulation, February 24, 2009; 119(7): 952 - 961.
[Abstract] [Full Text] [PDF]


Home page
CirculationHome page
S.-J. Park and Y.-H. Kim
Current Status of Percutaneous Coronary Intervention With Drug-Eluting Stents in Asia
Circulation, December 16, 2008; 118(25): 2730 - 2737.
[Full Text] [PDF]


Home page
Phil Trans R Soc AHome page
D.J.W Evans, P.V Lawford, J Gunn, D Walker, D.R Hose, R.H Smallwood, B Chopard, M Krafczyk, J Bernsdorf, and A Hoekstra
The application of multiscale modelling to the process of development and prevention of stenosis in a stented coronary artery
Phil Trans R Soc A, September 28, 2008; 366(1879): 3343 - 3360.
[Abstract] [Full Text] [PDF]