Donate Help Contact The AHA Sign In Home
American Heart Association
Circulation
Search: search_blue_button Advanced Search
Circulation. 2002;105:2324-2325
doi: 10.1161/01.CIR.0000013203.51417.55
This Article
Right arrow Full Text
Right arrow Full Text (PDF)
Right arrow Alert me when this article is cited
Right arrow Alert me if a correction is posted
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Download to citation manager
Right arrowRequest Permissions
Citing Articles
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Henein, M.
Right arrow Articles by Yacoub, M. H.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Henein, M.
Right arrow Articles by Yacoub, M. H.
Related Collections
Right arrow Contractile function
Right arrow Congestive
Right arrow Remodeling
Right arrow Heart failure - basic studies
Right arrow Imaging
Right arrow Quantitative modeling
Right arrow Transplantation
Right arrow Echocardiography
Right arrow CV surgery: transplantation, ventricular assistance, cardiomyopathy

(Circulation. 2002;105:2324.)
© 2002 American Heart Association, Inc.


Images in Cardiovascular Medicine

Temporal and Spatial Changes in Left Ventricular Pattern of Flow During Continuous Assist Device "HeartMate II"

Michael Henein, MRCP, MD; Emma J. Birks, MRCP, MD; Patrick D.T. Tansley, FRCS, MD; Christopher T. Bowles, PhD; Magdi H. Yacoub, FRS

From Royal Brompton and Harefield Trust and Imperial College School of Science, Technology and Medicine, London, UK.

Correspondence to Sir Magdi H. Yacoub, Professor of Cardiothoracic Surgery, Royal Brompton Hospital and Imperial College, Sydney St, London, SW3 6NP, United Kingdom. E-mail emmabirks@hotmail.com

The Heartmate II Left Ventricular Assist Device is a new axial impeller pump that is smaller than many existing devices and has no need for percutaneous venting. These features have the potential to reduce complications, lengthen durability, and enhance full implantability and good left ventricular unloading. The optimal operating conditions, however, remain to be elucidated. Changes in pump speed can produce temporal and spatial changes in the pattern of blood flow in the left ventricle (LV). These changes could influence the overall pump flow, cardiac rhythm, left ventricular function, structure, and possibly capacity to reverse remodeling. At different pump speeds, flow inside the ventricle was continuous throughout the cardiac cycle apart from a brief period during isovolumic contraction (arrow) (Figure 1A). At the slow pump speed of 9600 RPM, ventricular early diastolic flow velocity was augmented, particularly at mid-cavity level, where it reached a maximum of 0.6 m/s (Figure 2A). At a speed of 12 000 RPM, the flow pattern became disturbed with aliasing in early diastole at mid-cavity and apical levels (Figure 1B). This disturbance was associated with a striking 5-fold increase in velocity (exceeding 2.0 m/s; Figure 2B). This increase in velocity was the result of a reduced cross-sectional area at the mid-cavity level, which gave the ventricle an hourglass shape. At the same time, the proximal septal segment became reversed, possibly to maintain basal ventricular chamber size. These changes were observed consistently in 3 separate examinations at intervals of 5 . . . [Full Text of this Article]