Donate Help Contact The AHA Sign In Home
American Heart Association
Circulation
Search: search_blue_button Advanced Search
Circulation. 2001;103:e84

This Article
Right arrow Full Text
Right arrow Full Text (PDF)
Right arrow Cine Images
Right arrow Alert me when this article is cited
Right arrow Alert me if a correction is posted
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Download to citation manager
Right arrowRequest Permissions
Citing Articles
Right arrow Citing Articles via HighWire
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Yang, Z.
Right arrow Articles by Berr, S. S.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Yang, Z.
Right arrow Articles by Berr, S. S.
Related Collections
Right arrow Contractile function
Right arrow Animal models of human disease
Right arrow Imaging

(Circulation. 2001;103:e84.)
© 2001 American Heart Association, Inc.


Images in Cardiovascular Medicine

Cine Magnetic Resonance Imaging of Myocardial Ischemia and Reperfusion in Mice

Zequan Yang, MD, PhD; Brent A. French, PhD; Wesley D. Gilson, MS; Antwone J. Ross, MS; John N. Oshinski, PhD; Stuart S. Berr, PhD

From the Departments of Biomedical Engineering (Z.Y., B.A.F., W.D.G., A.J.R., J.N.O.) and Radiology (S.S.B.), University of Virginia Health System, Charlottesville, Va.

Correspondence to Stuart S. Berr, PhD, Department of Radiology, University of Virginia Health Sciences Center, MR4 Building, Room 1192, PO Box 801332, Charlottesville, VA 22908. E-mail berr@virginia.edu

Studies of acute myocardial ischemia/reperfusion injury in genetically manipulated mice have been impeded by the technical challenges of instrumenting small animals (<40 g) and assessing cardiac function at such rapid heart rates (>500 bpm). To address these problems, 4 C57BL/6 mice (28 to 30 g) were anesthetized with pentobarbital and intubated for surgical instrumentation of the major left coronary artery with pneumatically controlled balloon occluders. The distal end of the tubing from the balloon occluder was exteriorized at the back of the neck. One week later, each mouse was anesthetized with pentobarbital and fitted with surface ECG electrodes, and an extension tube was added to the balloon occluder. Mice were imaged on a Varian Inova 4.7T MR scanner using a Helmholtz radiofrequency coil. An ECG-triggered, 2D gradient echo sequence with an echo time of 3.9 ms and a flip angle of 20 degrees was used to obtain 12 phases per cardiac cycle at a final resolution of 100x100x1000 µm3.

Baseline cine images consisted of a series of 7 contiguous, 1-mm-thick, short-axis slices spanning the heart from apex to base. A myocardial stunning protocol consisting of a series of four 4-minute coronary occlusions interspersed with 4 minutes of reperfusion was then executed from a remote position outside of the magnet. Contiguous, short-axis cine MR images were successively acquired in the midventricular to apical regions of the left ventricle during each of the 4 balloon inflations. As shown in the FigureDown and the accompanying cine images, the . . . [Full Text of this Article]




This article has been cited by other articles:


Home page
Eur. J. Cardiothorac. Surg.Home page
C. Coghlan and J. Hoffman
Leonardo da Vinci's flights of the mind must continue: cardiac architecture and the fundamental relation of form and function revisited
Eur. J. Cardiothorac. Surg., April 1, 2006; 29(Suppl_1): S4 - S17.
[Abstract] [Full Text] [PDF]