Donate Help Contact The AHA Sign In Home
American Heart Association
Circulation
Search: search_blue_button Advanced Search
Circulation. 1998;98:1568-1574

This Article
Right arrow Full Text
Right arrow Full Text (PDF)
Right arrow Alert me when this article is cited
Right arrow Alert me if a correction is posted
Right arrow Citation Map
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Download to citation manager
Right arrowRequest Permissions
Citing Articles
Right arrow Citing Articles via HighWire
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Westaby, S.
Right arrow Articles by Jarvik, R.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Westaby, S.
Right arrow Articles by Jarvik, R.
Right arrowPubmed/NCBI databases
Medline Plus Health Information
*Heart Diseases

(Circulation. 1998;98:1568-1574.)
© 1998 American Heart Association, Inc.


Basic Science Reports

Jarvik 2000 Heart

Potential for Bridge to Myocyte Recovery

Stephen Westaby, MS, FRCS; Takahiro Katsumata, MD, PhD; Remi Houel, MD; Rhys Evans, MD; David Pigott, MD; O. H. Frazier, MD; ; Robert Jarvik, MD

From the Oxford Heart Centre (S.W., T.K., R.H., R.E., D.P.), Oxford, UK; the Texas Heart Institute (O.H.F.), Houston, Tex, and Jarvik Heart, Inc (R.J.), New York, NY.

Correspondence to Stephen Westaby, MS, FRCS, Oxford Heart Centre, John Radcliffe Hospital, Headley Way, Headington, Oxford OX3 9DU, UK.

Background—Mechanical bridge to left ventricular recovery is an emerging strategy for the treatment of heart failure. We sought to validate the use of a new intracardiac axial flow impeller pump for this purpose.

Methods and Results—The Jarvik 2000 Heart was implanted into 30 sheep to ascertain mechanical reliability, biocompatibility, and hemodynamic function. We attempted but failed to anticoagulate with warfarin. Elective explants with survival were performed in 3 animals to simulate bridge to recovery. Extensive autopsy studies were performed in all other animals. At speeds between 8000 and 12 000 rpm the device pumped up to 8 L/min, captured all mitral flow, and augmented cardiac output with elevation of mean arterial pressure. The pump was silent and hemolysis negligible. Nonpulsatile flow did not adversely affect neurological or renal function. Device removal proved straightforward and safe. A fractured inflow bearing occurred in 1 early model. There were no other pump failures, but power interruption occurred when the sheep chewed the cables or head-butted the percutaneous pedestal. At autopsy, there was no thromboembolism or primary thrombus formation in any device. Pump occlusion occurred in 2 sheep with bacterial endocarditis. One electively explanted pump, previously switched off for 5 months, had no thrombus in the device or vascular graft.

Conclusions—The Jarvik 2000 Heart is a major advance in blood-pump technology and increases the scope of mechanical circulatory support. Reliability and ease of removal favor its use for bridge to myocyte recovery, as well as for bridge to transplantation or long-term support.


Key Words: heart failure • myocytes • Jarvik 2000 • heart-assist device




This article has been cited by other articles:


Home page
Journal of Intelligent Material Systems and StructuresHome page
R. Ibuki, S. Maruyama, A. Komiya, and T. Yambe
Design of Plate-type Actuator using SMA Wire for Assistant Artificial Heart Muscle
Journal of Intelligent Material Systems and Structures, March 1, 2008; 19(3): 359 - 365.
[Abstract] [PDF]


Home page
Ann. Thorac. Surg.Home page
O. H. Frazier, T. J. Myers, S. Westaby, and I. D. Gregoric
Clinical experience with an implantable, intracardiac, continuous flow circulatory support device: physiologic implications and their relationship to patient selection
Ann. Thorac. Surg., January 1, 2004; 77(1): 133 - 142.
[Abstract] [Full Text] [PDF]


Home page
Anesth. Analg.Home page
N. A. Nussmeier, C. B. Probert, D. Hirsch, J. R. Cooper Jr., I. D. Gregoric, T. J. Myers, and O. H. Frazier
Anesthetic Management for Implantation of the Jarvik 2000TM Left Ventricular Assist System
Anesth. Analg., October 1, 2003; 97(4): 964 - 971.
[Abstract] [Full Text] [PDF]


Home page
Eur. J. Cardiothorac. Surg.Home page
S. Westaby, O.H. Frazier, F. Beyersdorf, S. Saito, M. P. Siegenthaler, D. W. Pigott, P. A. Catarino, and R. Jarvik
The Jarvik 2000 Heart. Clinical validation of the intraventricular position
Eur. J. Cardiothorac. Surg., August 1, 2002; 22(2): 228 - 232.
[Abstract] [Full Text] [PDF]


Home page
Ann. Thorac. Surg.Home page
T. A. Snyder, M. J. Watach, K. N. Litwak, and W. R. Wagner
Platelet activation, aggregation, and life span in calves implanted with axial flow ventricular assist devices
Ann. Thorac. Surg., June 1, 2002; 73(6): 1933 - 1938.
[Abstract] [Full Text] [PDF]


Home page
J. Thorac. Cardiovasc. Surg.Home page
S. Westaby, R. Jarvik, A. Freeland, D. Pigott, D. Robson, S. Saito, P. Catarino, and O. H. Frazier
Postauricular percutaneous power delivery for permanent mechanical circulatory support
J. Thorac. Cardiovasc. Surg., May 1, 2002; 123(5): 977 - 983.
[Abstract] [Full Text] [PDF]


Home page
Ann. Thorac. Surg.Home page
S. Westaby, O.H. Frazier, D. W. Pigott, S. Saito, and R. K. Jarvik
Implant technique for the Jarvik 2000 heart
Ann. Thorac. Surg., April 1, 2002; 73(4): 1337 - 1340.
[Abstract] [Full Text] [PDF]


Home page
Ann. Thorac. Surg.Home page
O.H. Frazier, T. J. Myers, R. K. Jarvik, S. Westaby, D. W. Pigott, I. D. Gregoric, T. Khan, D. W. Tamez, J. L. Conger, and M. P. Macris
Research and development of an implantable, axial-flow left ventricular assist device: the Jarvik 2000 Heart
Ann. Thorac. Surg., March 1, 2001; 71 (2007): S125 - S132.
[Abstract] [Full Text] [PDF]


Home page
Ann. Thorac. Surg.Home page
S. Westaby, T. Katsumata, D. Pigott, X. Y. Jin, K. Saatvedt, M. Horton, and R. E. Clark
Mechanical bridge to recovery in fulminant myocarditis
Ann. Thorac. Surg., July 1, 2000; 70(1): 278 - 282.
[Abstract] [Full Text] [PDF]


Home page
HeartHome page
S. Westaby
HEART FAILURE: Non-transplant surgery for heart failure
Heart, May 1, 2000; 83(5): 603 - 603.
[Full Text]


Home page
Arch. Dis. Child.Home page
S Westaby, O Franklin, and M Burch
New developments in the treatment of cardiac failure
Arch. Dis. Child., September 1, 1999; 81(3): 276 - 277.
[Full Text]