Donate Help Contact The AHA Sign In Home
American Heart Association
Circulation
Search: search_blue_button Advanced Search
Circulation. 1997;96:2808-2812

This Article
Right arrow Full Text
Right arrow Alert me when this article is cited
Right arrow Alert me if a correction is posted
Right arrow Citation Map
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Download to citation manager
Right arrowRequest Permissions
Citing Articles
Right arrow Citing Articles via HighWire
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Natale, A.
Right arrow Articles by Newby, K.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Natale, A.
Right arrow Articles by Newby, K.
Right arrowPubmed/NCBI databases
Medline Plus Health Information
*Arrhythmia
*High Risk Pregnancy
*Pacemakers and Implantable Defibrillators

(Circulation. 1997;96:2808-2812.)
© 1997 American Heart Association, Inc.


Articles

Implantable Cardioverter-Defibrillators and Pregnancy

A Safe Combination?

Andrea Natale, MD; Theresa Davidson, RN; Mary J. Geiger, MD; ; Keith Newby, MD1

From the Department of Cardiology (A.N., M.J.G., K.N.), Duke University Medical Center, and the Durham Veterans Administration Medical Center, Durham, NC; University of Michigan Medical Center (T.D.) (Ann Arbor); and University of Kentucky (A.N.) (Lexington).

Correspondence to Andrea Natale, MD, University of Kentucky, Division of Cardiovascular Medicine, Kentucky Clinic, Room L-543, Lexington, KY 40536-0284.

Background The purpose of this investigation was to evaluate the outcome of pregnancy in women with implantable cardioverter-defibrillators (ICDs).

Methods and Results A multicenter retrospective analysis was performed on women with an ICD who became pregnant. Data were collected on 44 patients. The mean age and ejection fraction at the time of the initial ICD implant were 25.6±4.9 years and 49.8±9.7%, respectively. The mean follow-up after the ICD implant was 4.8±2.8 years. Forty-two women had abdominally implanted generators, and 2 had a prepectoral device. Thirty had epicardial lead sensing systems, and 14 had transvenous. Thirty-six (82%) experienced no complications, and 8 (18%) had a medical or device-related complication. The ICD-related problems included tenderness at the ICD pocket scar (2 patients), generator migration (1), and pericarditis secondary to the epicardial patches (1). Medical complications were pulmonary embolism (1), therapeutic abortion (1), worsening hyperthyroidism (1), congestive heart failure (1), and weight loss (1). Thirty-seven women delivered vaginally, and 7 underwent cesarean section. Thirty-nine babies were born healthy, 1 was stillborn, 2 were small for gestational age, 1 had transient hypoglycemia, and 1 woman had a therapeutic abortion unrelated to the ICD. During pregnancy, 33 women received no ICD therapy, 8 had 1 shock, 1 had 5 discharges, 1 had 11 shocks, and 1 had 5 shocks. The total number of shocks during pregnancy ranged from 0 to 11, with an average of 0.66±1.9 discharges. Five women had 7 additional pregnancies without an ICD shock.

Conclusions The mere presence of an ICD should not defer a women from becoming pregnant unless she has an underlying structural cardiac disease that is considered a contraindication. Pregnancy does not increase the risk of major ICD-related complications or result in a high number of ICD discharges.


Key Words: defibrillation • death, sudden • morbidity • women




This article has been cited by other articles:


Home page
ESC Textbook of Cardiovascular MedicineHome page
P. Presbitero, G. G. Boccuzzi, C. J.M. Groot, and J. W. Roos-Hesselink
CHAPTER 33 Pregnancy and Heart Disease
ESC Textbook of Cardiovascular Medicine, January 1, 2009; 2(1): med-9780199566990-chapter - med-9780199566990-chapter.
[Abstract] [Full Text] [PDF]


Home page
Postgrad. Med. J.Home page
D L Adamson and C Nelson-Piercy
Managing palpitations and arrhythmias during pregnancy
Postgrad. Med. J., February 1, 2008; 84(988): 66 - 72.
[Full Text] [PDF]


Home page
HeartHome page
D. L Adamson and C. Nelson-Piercy
Managing palpitations and arrhythmias during pregnancy
Heart, December 1, 2007; 93(12): 1630 - 1636.
[Full Text] [PDF]


Home page
J Intensive Care MedHome page
H.-J. Trappe
Acute Therapy of Maternal and Fetal Arrhythmias During Pregnancy
J Intensive Care Med, September 1, 2006; 21(5): 305 - 315.
[Abstract] [PDF]


Home page
Am J Crit CareHome page
S. B. Dunbar
Psychosocial Issues of Patients With Implantable Cardioverter Defibrillators
Am. J. Crit. Care., July 1, 2005; 14(4): 294 - 303.
[Abstract] [Full Text] [PDF]


Home page
HeartHome page
S. C Siu and J. M Colman
CONGENITAL HEART DISEASE: Heart disease and pregnancy
Heart, June 1, 2001; 85(6): 710 - 715.
[Full Text]


Home page
Eur Heart JHome page
H.L. Tan and K.I. Lie
Treatment of tachyarrhythmias during pregnancy and lactation
Eur. Heart J., March 2, 2001; 22(6): 458 - 464.
[PDF]


Home page
EuropaceHome page
W. Bonini, G.L. Botto, T. Broffoni, and C. Dondina
Pregnancy with an ICD and a documented ICD discharge
Europace, January 1, 2000; 2(1): 87 - 90.
[Abstract] [PDF]


Home page
JWatch GeneralHome page
PREGNANCY IN WOMEN WITH HEART DISEASE: HOW SAFE?
Journal Watch (General), November 21, 1997; 1997(1121): 2 - 2.
[Full Text]