(Circulation. 1997;96:3880-3887.)
© 1997 American Heart Association, Inc.
Articles |
From the Medizinische Klinik rechts der Isar and Deutsches Herzzentrum (A.S., A.K., S.E., H.S., J.D.) Institut für Medizinische Statistik und Epidemiologie (F.D., M.W., K.U.), Technische Universität München, Munich, Germany.
Background Restenosis has been perceived as the tail end of a normal distribution of the response of the vessel to the intervention. However, recent studies have described a bimodal distribution for de novo lesions after percutaneous transluminal coronary angioplasty. This finding suggests that some lesions may be more susceptible for restenosis. Whether this holds true for a wider spectrum of lesions undergoing stent placement is not yet known. The present study analyzes the frequency distribution of angiographic indexes of restenosis 6 months after coronary stent implantation.
Methods and Results Quantitative angiographic evaluation was performed in 1084 lesions of 1084 patients before, immediately after, and 6 months after successful Palmaz-Schatz stent placement; this represented 80.4% of patients eligible for follow-up angiography. Principal end points of the analysis were angiographic indexes of restenosis at 6 months. Twenty-two lesions that became totally occluded at follow-up were excluded from most parts of the analysis. Diameter stenosis, minimal luminal diameter (MLD), and lumen loss at 6 months did not follow a normal pattern; the bimodal pattern was demonstrated through deconvolution that yielded two separate normal components delineating two lesion populations, which developed distinctively different degrees of lumen renarrowing. The first and larger subgroup of lesions, which was less prone to restenosis, was centered around a mean value of 27% for diameter stenosis and 2.19 mm for MLD, whereas the second subgroup, with a greater tendency for restenosis, was situated around a mean value of 68% for diameter stenosis and 0.76 mm for MLD. The intersection point between the two theoretical normal distribution components was 53.5% for diameter stenosis and 1.09 mm for MLD at follow-up.
Conclusions Frequency-distribution curves of angiographic indexes of restenosis after coronary stent placement have a bimodal pattern, suggesting the existence of two distinct populations with different propensity to restenosis. These findings may encourage future efforts for the timely identification of the subset with a higher risk as the target of specific antirestenotic strategies.
Key Words: stents coronary disease restenosis angioplasty
This article has been cited by other articles:
![]() |
P. Agostoni and G. G.L. Biondi-Zoccai Are Surrogate End Points in Drug-Eluting Stent Trials Reliable? J. Am. Coll. Cardiol., May 20, 2008; 51(20): 1991 - 1992. [Full Text] [PDF] |
||||
![]() |
J. Cosgrave, G. Melzi, S. Corbett, G. G.L. Biondi-Zoccai, P. Agostoni, R. Babic, F. Airoldi, A. Chieffo, G. M. Sangiorgi, M. Montorfano, et al. Comparable Clinical Outcomes With Paclitaxel- and Sirolimus-Eluting Stents in Unrestricted Contemporary Practice J. Am. Coll. Cardiol., June 19, 2007; 49(24): 2320 - 2328. [Abstract] [Full Text] [PDF] |
||||
![]() |
J. C.J. Sun, J. W. Eikelboom, P. Agostoni, G. M. Sangiorgi, G. G. Biondi-Zoccai, B. Scheller, M. Bohm, and E. Camenzind Treatment of Restenosis with a Paclitaxel-Coated Balloon Catheter N. Engl. J. Med., March 8, 2007; 356(10): 1071 - 1073. [Full Text] [PDF] |
||||
![]() |
P. Agostoni, L. Mauri, E. J. Orav, and R. E. Kuntz Letter Regarding Article by Mauri et al, "Late Loss in Lumen Diameter and Binary Restenosis for Drug-Eluting Stent Comparison" * Response Circulation, December 13, 2005; 112(24): e358 - e358. [Full Text] [PDF] |
||||
![]() |
P. S. Monraats, N. M. M. Pires, A. Schepers, W. R. P. Agema, L. S. M. Boesten, M. R. de Vries, A. H. Zwinderman, M. P. M. de Maat, P. A. F. M. Doevendans, R. J. de Winter, et al. Tumor necrosis factor-{alpha} plays an important role in restenosis development FASEB J, December 1, 2005; 19(14): 1998 - 2004. [Abstract] [Full Text] [PDF] |
||||
![]() |
P. A. Lemos, N. Mercado, R. T. van Domburg, R. E. Kuntz, W. W. O'Neill, and P. W. Serruys Comparison of Late Luminal Loss Response Pattern After Sirolimus-Eluting Stent Implantation or Conventional Stenting Circulation, November 16, 2004; 110(20): 3199 - 3205. [Abstract] [Full Text] [PDF] |
||||
![]() |
H.-P. Bestehorn, F.-J. Neumann, H. J. Buttner, P. Betz, P. Sturzenhofecker, E. von Hodenberg, A. Verdun, L. Levai, J. P. Monassier, and H. Roskamm Evaluation of the effect of oral verapamil on clinical outcome and angiographic restenosis after percutaneous coronary intervention: The randomized, double-blind, placebo-controlled, multicenter verapamil slow-release for prevention of cardiovascular events after angioplasty (VESPA) trial J. Am. Coll. Cardiol., June 16, 2004; 43(12): 2160 - 2165. [Abstract] [Full Text] [PDF] |
||||
![]() |
B. Bhargava, G. Karthikeyan, A. S Abizaid, and R. Mehran New approaches to preventing restenosis BMJ, July 31, 2003; 327(7409): 274 - 279. [Full Text] [PDF] |
||||
![]() |
K. Kwon, D. Choi, S.-H. Choi, Bon Kwon Koo, Y. Jang, W.-H. Shim, and S.-Y. Cho Coronary Stenting After Rotational Atherectomy in Diffuse Lesions of the Small Coronary Artery: Comparison with Balloon Angioplasty Before Stenting Angiology, July 1, 2003; 54(4): 423 - 431. [Abstract] [PDF] |
||||
![]() |
O. Gorchakova, W. Koch, N. von Beckerath, J. Mehilli, A. Schomig, and A. Kastrati Association of a genetic variant of endothelial nitric oxide synthase with the 1 year clinical outcome after coronary stent placement Eur. Heart J., May 1, 2003; 24(9): 820 - 827. [Abstract] [Full Text] [PDF] |
||||
![]() |
A. Kastrati, W. Koch, P. B. Berger, J. Mehilli, K. Stephenson, F.-J. Neumann, N. von Beckerath, C. Bottiger, G. W. Duff, and A. Schomig Protective role against restenosis from an interleukin-1 receptor antagonist gene polymorphism in patients treated with coronary stenting J. Am. Coll. Cardiol., December 1, 2000; 36(7): 2168 - 2173. [Abstract] [Full Text] [PDF] |
||||
![]() |
A. Kastrati, A. Schomig, J. Dirschinger, J. Mehilli, F. Dotzer, N. von Welser, and F.-J. Neumann A Randomized Trial Comparing Stenting With Balloon Angioplasty in Small Vessels in Patients With Symptomatic Coronary Artery Disease Circulation, November 21, 2000; 102(21): 2593 - 2598. [Abstract] [Full Text] [PDF] |
||||
![]() |
M. Gyongyosi, P. Yang, A. Khorsand, D. Glogar, on behalf of the Austrian Wiktor Stent Study Group, and European Paragon Stent Investigators Longitudinal straightening effect of stents is an additional predictor for major adverse cardiac events J. Am. Coll. Cardiol., May 1, 2000; 35(6): 1580 - 1589. [Abstract] [Full Text] [PDF] |
||||
![]() |
A. Buffon, G. Liuzzo, L. M. Biasucci, P. Pasqualetti, V. Ramazzotti, A. G. Rebuzzi, F. Crea, and A. Maseri Preprocedural serum levels of C-reactive protein predict early complications and late restenosis after coronary angioplasty J. Am. Coll. Cardiol., November 1, 1999; 34(5): 1512 - 1521. [Abstract] [Full Text] [PDF] |
||||
![]() |
A. Kastrati, A. Schomig, M. Seyfarth, W. Koch, S. Elezi, C. Bottiger, J. Mehilli, K. Schomig, and N. von Beckerath PlA Polymorphism of Platelet Glycoprotein IIIa and Risk of Restenosis After Coronary Stent Placement Circulation, March 2, 1999; 99(8): 1005 - 1010. [Abstract] [Full Text] [PDF] |
||||
![]() |
A. Kastrati, A. Schomig, S. Elezi, H. Schuhlen, M. Wilhelm, and J. Dirschinger Interlesion Dependence of the Risk for Restenosis in Patients With Coronary Stent Placement in Multiple Lesions Circulation, June 23, 1998; 97(24): 2396 - 2401. [Abstract] [Full Text] [PDF] |
||||
|
Circulation Home | Subscriptions | Archives | Feedback | Authors | Help | AHA Journals Home | Search Copyright © 1997 American Heart Association, Inc. All rights reserved. Unauthorized use prohibited. |