Donate Help Contact The AHA Sign In Home
American Heart Association
Circulation
Search: search_blue_button Advanced Search
Circulation. 1997;95:2254-2261

This Article
Right arrow Full Text
Right arrow Alert me when this article is cited
Right arrow Alert me if a correction is posted
Right arrow Citation Map
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Download to citation manager
Right arrowRequest Permissions
Citing Articles
Right arrow Citing Articles via HighWire
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Peters, R. J.G.
Right arrow Articles by Bom, N.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Peters, R. J.G.
Right arrow Articles by Bom, N.
Right arrowPubmed/NCBI databases
Medline Plus Health Information
*Angioplasty

(Circulation. 1997;95:2254-2261.)
© 1997 American Heart Association, Inc.


Articles

Prediction of Restenosis After Coronary Balloon Angioplasty

Results of PICTURE (Post–IntraCoronary Treatment Ultrasound Result Evaluation), a Prospective Multicenter Intracoronary Ultrasound Imaging Study

Ron J.G. Peters, MD; Wouter E.M. Kok, MD; Carlo Di Mario, MD; Patrick W. Serruys, MD; Frits W.H.M. Bär, MD; Gerard Pasterkamp, MD; Cornelis Borst, MD; Otto Kamp, MD; Jean G.F. Bronzwaer, MD; Cees A. Visser, MD; Jan J. Piek, MD; Radjan N. Panday, MD; Wiebe Jaarsma, MD; Lucas Savalle, MD; Nicolaas Bom, PhD; for the PICTURE Study Group

Interuniversity Cardiology Institute of the Netherlands, Utrecht.

Correspondence to Ron J.G. Peters, MD, Department of Cardiology, Room G3-228, Academic Medical Center, Meibergdreef 9, 1105 AZ Amsterdam, Netherlands.

Background Intracoronary ultrasound (ICUS) imaging is potentially suitable to identify lesions at high risk of restenosis after percutaneous transluminal coronary angioplasty (PTCA), but it has not been studied systematically.

Methods and Results We recruited 200 patients in whom ICUS studies were performed after successful PTCA and related their ICUS parameters to 6-month follow-up quantitative coronary angiography. This was performed in 164 patients (82%), yielding 170 lesions for analysis. The overall incidence of a >=50% diameter stenosis at follow-up (categorical restenosis) was 29.4%. Quantitative ICUS parameters were weakly but significantly related to follow-up minimal luminal diameter on quantitative coronary angiography (lumen area: R2=.36, P=.0001; vessel area: R2=.29, P=.0002; plaque area: R2=-.18, P=.021; percent obstruction: R2=-.15, P=.05), but categorical restenosis was not significantly related to these parameters (P=.63, .77, .38, and .08, respectively). There were no significant predictors of restenosis in ICUS parameters of plaque morphology: eccentric versus concentric (P=1.0), plaque type (hard, soft, or calcific, P=.98), or the number of calcified quadrants (P=.41). There were no significant predictors of restenosis in two predefined types of vessel-wall disruptions: (1) rupture: presence (P=.79), depth (partial versus complete, P=.85), or extent in quadrants (P=.6), and (2) dissection: presence (P=.31), depth (P=.82), or extent (P=.38).

Conclusions Qualitative ICUS parameters after PTCA did not predict restenosis. A larger lumen and vessel area and a smaller plaque area by ICUS were associated with a larger angiographic minimal lumen diameter at follow-up, but these parameters were not significantly related to categorical restenosis.


Key Words: restenosis • angioplasty • ultrasonics




This article has been cited by other articles:


Home page
ESC Textbook of Cardiovascular MedicineHome page
C. Di Mario, G. R. Heyndrickx, F. Prati, and N. H.J. Pijls
CHAPTER 8 Invasive Imaging and Haemodynamics
ESC Textbook of Cardiovascular Medicine, January 1, 2009; 2(1): med-9780199566990-chapter - med-9780199566990-chapter.
[Abstract] [Full Text] [PDF]


Home page
CirculationHome page
R. Kettelkamp, J. House, M. Garg, R. S. Stuart, A. Grantham, and J. Spertus
Using the Risk of Restenosis as a Guide to Triaging Patients Between Surgical and Percutaneous Coronary Revascularization
Circulation, September 14, 2004; 110(11_suppl_1): II-50 - II-54.
[Abstract] [Full Text] [PDF]


Home page
Cardiovasc ResHome page
B. Liu, M. Fisher, and P. Groves
Down-regulation of the ERK1 and ERK2 mitogen-activated protein kinases using antisense oligonucleotides inhibits intimal hyperplasia in a porcine model of coronary balloon angioplasty
Cardiovasc Res, June 1, 2002; 54(3): 640 - 648.
[Abstract] [Full Text] [PDF]


Home page
ANGIOLOGYHome page
H. Alfke, J. J. Froelich, S. Nowak, and H.-J. Wagner
Cardiovascular Risk Factors Do Not Predict Clinically Defined Restenosis After Percutaneous Transluminal Angioplasty for Lower Limb Ischemia
Angiology, January 1, 2002; 53(1): 15 - 20.
[Abstract] [PDF]


Home page
J Am Coll CardiolHome page
N. Mercado, E. Boersma, W. Wijns, B. J. Gersh, C. A. Morillo, V. de Valk, G.-A. van Es, D. E. Grobbee, and P. W. Serruys
Clinical and quantitative coronary angiographic predictors of coronary restenosis: A comparative analysis from the balloon-to-stent era
J. Am. Coll. Cardiol., September 1, 2001; 38(3): 645 - 652.
[Abstract] [Full Text] [PDF]


Home page
J Am Coll CardiolHome page
H. Okura, Y. Morino, A. Oshima, M. Hayase, M. R. Ward, J. J. Popma, R. E. Kuntz, H. N. Bonneau, P. G. Yock, and P. J. Fitzgerald
Preintervention arterial remodeling affects clinical outcome following stenting: an intravascular ultrasound study
J. Am. Coll. Cardiol., March 15, 2001; 37(4): 1031 - 1035.
[Abstract] [Full Text] [PDF]


Home page
CirculationHome page
S. E. Nissen and P. Yock
Intravascular Ultrasound : Novel Pathophysiological Insights and Current Clinical Applications
Circulation, January 30, 2001; 103(4): 604 - 616.
[Abstract] [Full Text] [PDF]


Home page
CirculationHome page
K. Hibi, A. Takagi, X. Zhang, T.-J. Teo, H. N. Bonneau, P. G. Yock, and P. J. Fitzgerald
Feasibility of a Novel Blood Noise Reduction Algorithm to Enhance Reproducibility of Ultra-High-Frequency Intravascular Ultrasound Images
Circulation, October 3, 2000; 102(14): 1657 - 1663.
[Abstract] [Full Text] [PDF]


Home page
J Am Coll CardiolHome page
W. J. Cantor, E. D. Peterson, J. J. Popma, J. P. Zidar, M. H. Sketch Jr., J. E. Tcheng, and E. M. Ohman
Provisional stenting strategies: systematic overview and implications for clinical decision-making
J. Am. Coll. Cardiol., October 1, 2000; 36(4): 1142 - 1151.
[Abstract] [Full Text] [PDF]


Home page
Eur Heart JHome page
F. Alfonso
Videodensitometric vs edge-detection quantitative angiography. Insights from intravascular ultrasound imaging
Eur. Heart J., April 2, 2000; 21(8): 604 - 607.
[PDF]


Home page
Eur Heart JHome page
R.J.G Peters, W.E.M Kok, G Pasterkamp, C Von Birgelen, M Prins, and P.W Serruys
Videodensitometric quantitative angiography after coronary balloon angioplasty, compared to edge-detection quantitative angiography and intracoronary ultrasound imaging
Eur. Heart J., April 2, 2000; 21(8): 654 - 661.
[Abstract] [PDF]


Home page
CirculationHome page
D. P. Faxon
Predicting Restenosis : Bigger Is Better but Not Best
Circulation, March 7, 2000; 101(9): 946 - 947.
[Full Text] [PDF]


Home page
J Am Coll CardiolHome page
W. E. M. Kok, R. J. G. Peters, G. Pasterkamp, C. Di Mario, P. W. Serruys, M. Prins, C. A. Visser, and for the PICTURE study group
Greater late lumen loss after successful coronary balloon angioplasty in the proximal left anterior descending coronary artery is not explained by extent of vessel wall damage or plaque burden
J. Am. Coll. Cardiol., February 1, 2000; 35(2): 382 - 388.
[Abstract] [Full Text] [PDF]


Home page
HeartHome page
C von Birgelen, G S Mintz, E A de Vrey, P W Serruys, T Kimura, M Nobuyoshi, J J Popma, M B Leon, R Erbel, and P J de Feyter
Preintervention lesion remodelling affects operative mechanisms of balloon optimised directional coronary atherectomy procedures: a volumetric study with three dimensional intravascular ultrasound
Heart, February 1, 2000; 83(2): 192 - 197.
[Abstract] [Full Text]


Home page
J Am Coll CardiolHome page
P. H. Grewe, T. Deneke, A. Machraoui, J.u. Barmeyer, and K.-M. Muller
Acute and chronic tissue response to coronary stent implantation: pathologic findings in human specimen
J. Am. Coll. Cardiol., January 1, 2000; 35(1): 157 - 163.
[Abstract] [Full Text] [PDF]


Home page
Asian Cardiovasc. Thorac. Ann.Home page
A. Magdy, M. Al-Abbady, A. Ghoga, K. Heib, and C. Ozbek
Restenosis After Angioplasty in Patients with Left Ventricular Dysfunction
Asian Cardiovasc Thorac Ann, September 1, 1999; 7(3): 209 - 213.
[Abstract] [Full Text] [PDF]


Home page
J Am Coll CardiolHome page
P. J. Scanlon, D. P. Faxon, A.-M. Audet, B. Carabello, G. J. Dehmer, K. A. Eagle, R. D. Legako, D. F. Leon, J. A. Murray, S. E. Nissen, et al.
ACC/AHA guidelines for coronary angiography: A report of the American College of Cardiology/American Heart Association Task Force on Practice Guidelines (Committee on Coronary Angiography) developed in collaboration with the Society for Cardiac Angiography and Interventions
J. Am. Coll. Cardiol., May 1, 1999; 33(6): 1756 - 1824.
[Full Text] [PDF]


Home page
CirculationHome page
G. J. W. Bech, N. H. J. Pijls, B. De Bruyne, K. H. Peels, H. R. Michels, H. J. R. M. Bonnier, and J. J. Koolen
Usefulness of Fractional Flow Reserve to Predict Clinical Outcome After Balloon Angioplasty
Circulation, February 23, 1999; 99(7): 883 - 888.
[Abstract] [Full Text] [PDF]


Home page
J Am Coll CardiolHome page
Y. Nishimoto, Y. Miyazaki, Y. Toki, R. Murakami, M. Shinoda, A. Fukushima, and H. Kanayama
Enhanced secretion of insulin plays a role in the development of atherosclerosis and restenosis of coronary arteries: elective percutaneous transluminal coronary angioplasty in patients with effort angina
J. Am. Coll. Cardiol., November 15, 1998; 32(6): 1624 - 1629.
[Abstract] [Full Text] [PDF]


Home page
Vasc MedHome page
A. Oshima, D. Itchhaporia, and P. Fitzgerald
New developments in intravascular ultrasound
Vascular Medicine, November 1, 1998; 3(4): 281 - 290.
[Abstract] [PDF]


Home page
CirculationHome page
C. R. Narins, D. R. Holmes Jr, and E. J. Topol
A Call for Provisional Stenting : The Balloon Is Back!
Circulation, April 7, 1998; 97(13): 1298 - 1305.
[Full Text] [PDF]


Home page
HeartHome page
C von Birgelen, G S Mintz, E A de Vrey, T Kimura, J J Popma, S G Airiian, M B Leon, M Nobuyoshi, P W Serruys, and P J de Feyter
Atherosclerotic coronary lesions with inadequate compensatory enlargement have smaller plaque and vessel volumes: observations with three dimensional intravascular ultrasound in vivo
Heart, February 1, 1998; 79(2): 137 - 142.
[Abstract] [Full Text]


Home page
CirculationHome page
D. P. Faxon
Identifying the Predictors of Restenosis: Do We Need New Glasses?
Circulation, May 6, 1997; 95(9): 2244 - 2246.
[Full Text]