Background Previous studies showed that moderate and severe acute cardiac rejection (AR) but not mild AR is associated with significant myocardial acoustic changes. This study examines whether serial measurements of end-diastolic two-dimensional integrated backscatter (2D-IB) enhance the diagnostic potential of ultrasonic tissue analysis in AR.
Methods and Results Serial endomyocardial biopsies, conventional echocardiograms, and parasternal long-axis radiofrequency signals for determination of posterior wall and septal 2D-IB were performed in 52 transplant patients. Histology showed no AR in 155 biopsy samples, AR grade 1A in 25, AR grade 1B/2 in 27, and AR grade 3A/3B in 13. Whereas no significant 2D-IB changes occurred between AR-free studies and during AR grade 1A, posterior wall and septal 2D-IB increased during AR grade 1B/2 from -47.80±4.36 to -42.97±5.11 dB and from -36.72±7.45 to -32.52±7.98 dB (P<.001 and P<.05, respectively) and during AR grade 3A/3B from -47.96±4.74 to -38.25±5.32 dB and from -37.92±5.87 to -31.01±4.62 dB (P<.001 and P<.01, respectively). Changes in posterior wall and septal 2D-IB were greater during AR grade 3A/3B than during AR grade 1B/2 (P<.01 and P<.05). Increases of 1.5 dB in posterior wall or septal 2D-IB indicated AR grades
1B with sensitivities of 88% and 83% and specificities of 89% and 85%; posterior wall and septal 2D-IB increases of 5.5 and 3.8 dB identified AR grades
3A with sensitivities of 92% and 79% and specificities of 90% and 84%. Although a weak inverse correlation between posterior wall and septal 2D-IB changes and posterior wall and septal thickening (r=.41 and r=.39, both P<.001) and fractional diameter shortening (r=.35, P<.001) was found, significant 2D-IB increases also occurred in some rejecting patients with unaltered contraction.
Conclusions Increases in end-diastolic posterior wall and septal 2D-IB in serial studies permit reliable identification not only of moderate and severe AR but also of mild AR. Because 2D-IB increases significantly more in AR with myocyte damage than without such damage, an estimate of AR severity appears feasible. Significant myocardial acoustic changes during AR may occur independently of changes in contractile performance.
Key Words: rejection echocardiography tissue transplantation
This article has been cited by other articles:
![]() |
H. N. Skouri, G. W. Dec, M. G. Friedrich, and L. T. Cooper Noninvasive Imaging in Myocarditis J. Am. Coll. Cardiol., November 21, 2006; 48(10): 2085 - 2093. [Abstract] [Full Text] [PDF] |
||||
![]() |
J. Koyama, P. A. Ray-Sequin, and R. H. Falk Prognostic Significance of Ultrasound Myocardial Tissue Characterization in Patients With Cardiac Amyloidosis Circulation, July 30, 2002; 106(5): 556 - 561. [Abstract] [Full Text] [PDF] |
||||
![]() |
G. Derumeaux, J. Loufoua, G. Pontier, A. Cribier, and M. Ovize Tissue Doppler Imaging Differentiates Transmural From Nontransmural Acute Myocardial Infarction After Reperfusion Therapy Circulation, January 30, 2001; 103(4): 589 - 596. [Abstract] [Full Text] [PDF] |
||||
![]() |
F. G. Blankenberg, P. D. Katsikis, J. F. Tait, R. E. Davis, L. Naumovski, K. Ohtsuki, S. Kopiwoda, M. J. Abrams, M. Darkes, R. C. Robbins, et al. In vivo detection and imaging of phosphatidylserine expression during programmed cell death PNAS, May 26, 1998; 95(11): 6349 - 6354. [Abstract] [Full Text] [PDF] |
||||
|
Circulation Home | Subscriptions | Archives | Feedback | Authors | Help | AHA Journals Home | Search Copyright © 1997 American Heart Association, Inc. All rights reserved. Unauthorized use prohibited. |