| ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
(Circulation. 1996;93:753-762.)
© 1996 American Heart Association, Inc.
Articles |
From the Department of Cardiology, Hospital General Gregorio Marañón, Facultad de Medicina de la Universidad Complutense, Madrid, Spain.
Correspondence to Jesús Almendral, MD, Laboratorio de Electrofisiología, Departamento de Cardiología, Hospital General Gregorio Marañón (Planta 5), Calle Dr Esquerdo 46, 28007 Madrid, Spain.
Background Some patients with an automatic implantable cardioverter-defibrillator (ICD) suffer multiple appropriate, consecutive, high-energy discharges (MCDs) during follow-up. Such events might represent resistant ventricular arrhythmias and might have prognostic significance.
Methods and Results Eighty consecutive patients with an ICD were followed up for up to 82 months (mean, 21±19 months). Thirty-eight patients had survived an out-of-hospital cardiac arrest and 42 had recurrent ventricular tachycardia. During follow-up, 16 patients had MCD (group A), 26 patients had episodes of single appropriate discharges (group B), and 38 patients had no appropriate discharges (group C). Group A patients had worse functional status (P=.001), lower left ventricular ejection fractions (LVEFs) (P=.001), and lower survival rates (log rank, P=.003) than the remaining two groups of patients. Cox analysis showed LVEF (P=.001) to be an independent predictor of MCD. Independent predictors of death or heart transplant were MCD (P=.001), female sex (P=.001), age (P=.001), history of cardiac arrest (P=.003), and functional status (P=.003). The only independent predictor of total mortality was female sex (P=.002). Independent predictors of cardiac death were MCD (P=.007) and female sex (P=.018). Independent predictors of arrhythmic death were age (P=.001), female sex (P=.02), and MCD (P=.023).
Conclusions In patients with an ICD, the development of MCD is an independent predictor of cardiac and arrhythmic mortality. If this finding is confirmed in larger studies, it may help to identify patients in whom other therapeutic alternatives, ie, heart transplantation, should be considered during follow-up after ICD implantation.
Key Words: defibrillation survival prognosis tachyarrhythmias
This article has been cited by other articles:
![]() |
J. L. Sapp Venturing Into the Storm Circulation, January 29, 2008; 117(4): 456 - 457. [Full Text] [PDF] |
||||
![]() |
C. Carbucicchio, M. Santamaria, N. Trevisi, G. Maccabelli, F. Giraldi, G. Fassini, S. Riva, M. Moltrasio, M. Cireddu, F. Veglia, et al. Catheter Ablation for the Treatment of Electrical Storm in Patients With Implantable Cardioverter-Defibrillators: Short- and Long-Term Outcomes in a Prospective Single-Center Study Circulation, January 29, 2008; 117(4): 462 - 469. [Abstract] [Full Text] [PDF] |
||||
![]() |
V. Y. Reddy, M. R. Reynolds, P. Neuzil, A. W. Richardson, M. Taborsky, K. Jongnarangsin, S. Kralovec, L. Sediva, J. N. Ruskin, and M. E. Josephson Prophylactic Catheter Ablation for the Prevention of Defibrillator Therapy N. Engl. J. Med., December 27, 2007; 357(26): 2657 - 2665. [Abstract] [Full Text] [PDF] |
||||
![]() |
J. Almendral and M. E. Josephson All Patients With Hemodynamically Tolerated Postinfarction Ventricular Tachycardia Do Not Require an Implantable Cardioverter-Defibrillator Circulation, September 4, 2007; 116(10): 1204 - 1212. [Full Text] [PDF] |
||||
![]() |
A. K. Gehi, D. Mehta, and J. A. Gomes Evaluation and Management of Patients After Implantable Cardioverter-Defibrillator Shock JAMA, December 20, 2006; 296(23): 2839 - 2847. [Abstract] [Full Text] [PDF] |
||||
![]() |
A. Elhendy, S. Chapman, T. R. Porter, and J. Windle Association of Myocardial Ischemia With Mortality and Implantable Cardioverter-Defibrillator Therapy in Patients With Coronary Artery Disease at Risk of Arrhythmic Death J. Am. Coll. Cardiol., November 1, 2005; 46(9): 1721 - 1726. [Abstract] [Full Text] [PDF] |
||||
![]() |
L.J. Jordaens and J.M. Mekel Electrical storm in the ICD era Europace, January 1, 2005; 7(2): 181 - 183. [Full Text] [PDF] |
||||
![]() |
K. A. Gatzoulis, G. K. Andrikopoulos, T. Apostolopoulos, E. Sotiropoulos, G. Zervopoulos, J. Antoniou, S. Brili, and C. I. Stefanadis Electrical storm is an independent predictor of adverse long-term outcome in the era of implantable defibrillator therapy Europace, January 1, 2005; 7(2): 184 - 192. [Abstract] [Full Text] [PDF] |
||||
![]() |
P. Dorian, M. Borggrefe, H. R. Al-Khalidi, S. H. Hohnloser, J. M. Brum, D. S. Tatla, J. Brachmann, R. J. Myerburg, D. S. Cannom, M. van der Laan, et al. Placebo-Controlled, Randomized Clinical Trial of Azimilide for Prevention of Ventricular Tachyarrhythmias in Patients With an Implantable Cardioverter Defibrillator Circulation, December 14, 2004; 110(24): 3646 - 3654. [Abstract] [Full Text] [PDF] |
||||
![]() |
G. Gronefeld and S. H Hohnloser What do implantable cardioverter/defibrillators teach us about the mechanisms of sudden cardiac death? Cardiovasc Res, May 1, 2001; 50(2): 232 - 241. [Abstract] [Full Text] [PDF] |
||||
![]() |
S. Nisam A Prophylactic ICD? Who are the patients? What is the device? Europace, January 1, 2001; 3(4): 269 - 274. [PDF] |
||||
![]() |
D. Bansch, D. Bocker, J.u. Brunn, M. Weber, G.u. Breithardt, and M. Block Clusters of ventricular tachycardias signify impaired survival in patients with idiopathic dilated cardiomyopathy and implantable cardioverter defibrillators J. Am. Coll. Cardiol., August 1, 2000; 36(2): 566 - 573. [Abstract] [Full Text] [PDF] |
||||
![]() |
M. Greene, D. Newman, M. Geist, M. Paquette, D. Heng, and P. Dorian Is electrical storm in ICD patients the sign of a dying heart?: Outcome of patients with clusters of ventricular tachyarrhythmias Europace, January 1, 2000; 2(3): 263 - 269. [Abstract] [PDF] |
||||
![]() |
A. Pacifico, L. L. Ferlic, F.e. R. Cedillo-Salazar, N. Nasir Jr, T. K. Doyle, and P. D. Henry Shocks as predictors of survival in patients with implantable cardioverter-defibrillators J. Am. Coll. Cardiol., July 1, 1999; 34(1): 204 - 210. [Abstract] [Full Text] [PDF] |
||||
![]() |
S. C. Credner, T. Klingenheben, O. Mauss, C. Sticherling, and S. H. Hohnloser Electrical storm in patients with transvenous implantable cardioverter-defibrillators: Incidence, management and prognostic implications J. Am. Coll. Cardiol., December 1, 1998; 32(7): 1909 - 1915. [Abstract] [Full Text] [PDF] |
||||
![]() |
C. D. Swerdlow, C. T. Peter, R. M. Kass, E. S. Gang, W. J. Mandel, C. Hwang, D. J. Martin, and P.-S. Chen Programming of Implantable Cardioverter-Defibrillators on the Basis of the Upper Limit of Vulnerability Circulation, March 18, 1997; 95(6): 1497 - 1504. [Abstract] [Full Text] |
||||
![]() |
A. Pacifico, K. R. Wheelan, N. Nasir, P. J. Wells, T. K. Doyle, S. A. Johnson, and P. D. Henry Long-term Follow-up of Cardioverter-Defibrillator Implanted Under Conscious Sedation in Prepectoral Subfascial Position Circulation, February 18, 1997; 95(4): 946 - 950. [Abstract] [Full Text] |
||||
|
Circulation Home | Subscriptions | Archives | Feedback | Authors | Help | AHA Journals Home | Search Copyright © 1996 American Heart Association, Inc. All rights reserved. Unauthorized use prohibited. |