(Circulation. 1996;93:594-602.)
© 1996 American Heart Association, Inc.
Articles |
From the Oregon Health Sciences University, Portland (T.S., M.I., B.S., S.H., D.J.S.); the Laboratory of Animal Medicine and Surgery, National Institutes of Health, Bethesda, Md (M.J., I.Y.); and the School of Chemical Engineering, Georgia Institute of Technology, Atlanta (R.S.H., A.P.Y.).
Background The aim of the present study was to evaluate dynamic changes in aortic regurgitant (AR) orifice area with the use of calibrated electromagnetic (EM) flowmeters and to validate a color Doppler flow convergence (FC) method for evaluating effective AR orifice area and regurgitant volume.
Methods and Results In 6 sheep, 8 to 20 weeks after surgically induced AR, 22 hemodynamically different states were studied. Instantaneous regurgitant flow rates were obtained by aortic and pulmonary EM flowmeters balanced against each other. Instantaneous AR orifice areas were determined by dividing these actual AR flow rates by the corresponding continuous wave velocities (over 25 to 40 points during each diastole) matched for each steady state. Echo studies were performed to obtain maximal aliasing distances of the FC in a low range (0.20 to 0.32 m/s) and a high range (0.70 to 0.89 m/s) of aliasing velocities; the corresponding maximal AR flow rates were calculated using the hemispheric flow convergence assumption for the FC isovelocity surface. AR orifice areas were derived by dividing the maximal flow rates by the maximal continuous wave Doppler velocities. AR orifice sizes obtained with the use of EM flowmeters showed little change during diastole. Maximal and time-averaged AR orifice areas during diastole obtained by EM flowmeters ranged from 0.06 to 0.44 cm2 (mean, 0.24±0.11 cm2) and from 0.05 to 0.43 cm2 (mean, 0.21±0.06 cm2), respectively. Maximal AR orifice areas by FC using low aliasing velocities overestimated reference EM orifice areas; however, at high AV, FC predicted the reference areas more reliably (0.25±0.16 cm2, r=.82, difference=0.04±0.07 cm2). The product of the maximal orifice area obtained by the FC method using high AV and the velocity time integral of the regurgitant orifice velocity showed good agreement with regurgitant volumes per beat (r=.81, difference=0.9±7.9 mL/beat).
Conclusions This study, using strictly quantified AR volume, demonstrated little change in AR orifice size during diastole. When high aliasing velocities are chosen, the FC method can be useful for determining effective AR orifice size and regurgitant volume.
Key Words: aortic regurgitation echocardiography blood flow hemodynamics
This article has been cited by other articles:
![]() |
Y Miyake, T Hozumi, I Mori, K Sugioka, A Yamamuro, T Akasaka, S Homma, K Yoshida, and J Yoshikawa Automated quantification of aortic regurgitant volume and regurgitant fraction using the digital colour Doppler velocity profile integration method in patients with aortic regurgitation Heart, December 1, 2002; 88(5): 481 - 484. [Abstract] [Full Text] [PDF] |
||||
![]() |
Y J Kim, M Jones, T Shiota, H Tsujino, J X Qin, F Bauer, M Sitges, J Kwan, L A Cardon, A D Zetts, et al. Effect of load alterations on the effective regurgitant orifice area in chronic aortic regurgitation Heart, October 1, 2002; 88(4): 397 - 400. [Abstract] [Full Text] [PDF] |
||||
![]() |
M. Sitges, M. Jones, T. Shiota, D. L. Prior, J. X. Qin, H. Tsujino, F. Bauer, Y. J. Kim, D. Deserranno, N. L. Greenberg, et al. Interaliasing distance of the flow convergence surface for determining mitral regurgitant volume: a validation study in a chronic animal model J. Am. Coll. Cardiol., October 1, 2001; 38(4): 1195 - 1202. [Abstract] [Full Text] [PDF] |
||||
![]() |
T Irvine, X N Li, R Rusk, D Lennon, D J Sahn, and A Kenny Three dimensional colour Doppler echocardiography for the characterisation and quantification of cardiac flow events Heart, November 1, 2000; 84(90002): 2i - 6. [Full Text] |
||||
![]() |
T. Shiota, M. Jones, S. Aida, M. Chikada, H. Tsujino, T. El-Kadi, and D. J. Sahn Validation of the accuracy of both right and left ventricular outflow volume determinations and semiautomated calculation of shunt volumes through atrial septal defects by digital color Doppler flow mapping in a chronic animal model J. Am. Coll. Cardiol., August 1, 1999; 34(2): 587 - 593. [Abstract] [Full Text] [PDF] |
||||
![]() |
Y. Mori, T. Shiota, M. Jones, S. Wanitkun, T. Irvine, X. Li, A. Delabays, N. G. Pandian, and D. J. Sahn Three-Dimensional Reconstruction of the Color Doppler–Imaged Vena Contracta for Quantifying Aortic Regurgitation : Studies in a Chronic Animal Model Circulation, March 30, 1999; 99(12): 1611 - 1617. [Abstract] [Full Text] [PDF] |
||||
![]() |
C. M. Tribouilloy, M. Enriquez-Sarano, S. L. Fett, K. R. Bailey, J. B. Seward, and A. J. Tajik Application of the proximal flow convergence method to calculate the effective regurgitant orifice area in aortic regurgitation J. Am. Coll. Cardiol., October 1, 1998; 32(4): 1032 - 1039. [Abstract] [Full Text] [PDF] |
||||
![]() |
T. Shiota, M. Jones, A. Delabays, X. Li, I. Yamada, M. Ishii, P. Acar, S. Holcomb, N. G. Pandian, and D. J. Sahn Direct Measurement of Three-dimensionally Reconstructed Flow Convergence Surface Area and Regurgitant Flow in Aortic Regurgitation : In Vitro and Chronic Animal Model Studies Circulation, November 18, 1997; 96(10): 3687 - 3695. [Abstract] [Full Text] |
||||
![]() |
M. Ishii, M. Jones, T. Shiota, I. Yamada, R. S. Heinrich, S. R. Holcomb, A. P. Yoganathan, and D. J. Sahn Quantifying Aortic Regurgitation by Using the Color Doppler–Imaged Vena Contracta : A Chronic Animal Model Study Circulation, September 16, 1997; 96(6): 2009 - 2015. [Abstract] [Full Text] |
||||
|
Circulation Home | Subscriptions | Archives | Feedback | Authors | Help | AHA Journals Home | Search Copyright © 1996 American Heart Association, Inc. All rights reserved. Unauthorized use prohibited. |