(Circulation. 1995;92:579-586.)
© 1995 American Heart Association, Inc.
Articles |
From Department of Thoracic and Cardiovascular Surgery and MR Centre, Institute of Experimental Clinical Research, Aarhus University Hospital (S.O., E.M.P., K.H.), Skejby Sygehus, Aarhus, Denmark; and School of Chemical Engineering, Georgia Institute of Technology, Atlanta, Ga.
Correspondence to Peter G. Walker, PhD, Cardiovascular Fluid Mechanics Laboratory, School of Chemical Engineering, Georgia Institute of Technology, Atlanta, GA 30332-0100.
Background The purpose of the present study was to develop a new method of measuring heart valvular regurgitation based on control volume theory and to verify its accuracy in vitro and in vivo. Current methods of quantifying valvular regurgitation rely too much on assumptions about the flow field and therefore are difficult to apply in vivo. In particular, the proximal isovelocity surface area (PISA) method oversimplifies the proximal velocity field by assuming hemispherical isovelocity contours proximal to the orifice. This severely limits the applicability of the PISA method. Use of the basic control volume theory, however, removes the need to assume the manner in which the proximal flow accelerates toward the regurgitant orifice, the shape and size of the orifice, the shape of the orifice plate, and the non-newtonian behavior of the fluid. Apart from a correction that is necessary if the orifice plate is moving, the control volume method assumes only the incompressibility of the fluid and therefore is a potentially more accurate approach. In addition, the use of magnetic resonance imaging (MRI) precludes the need for an acoustic window.
Methods and Results MRI has been used to measure the three-dimensional velocity field proximal to regurgitant orifices, including single and multiple orifices and a cone-shaped orifice plate. Both steady (0 to 7.5 L/min) and pulsatile (2 and 3 L/min) flows were used. By integrating this velocity over a control volume surrounding the orifice, we calculated the flow rate through the orifice. As a validation, the cardiac output of a 50-kg pig also was measured and was compared with thermodilution measurements. It was found that MRI could be used to measure the three-dimensional flow proximal to regurgitant orifices. This enabled the calculation of the flow rate through the orifice by integrating the velocity over the surface of a control volume covering the orifice. This flow rate correlated well with the actual flow rate (0.992; correlation line slope, 1.01). Care had to be taken, however, to exclude from the integration regions of aliased velocity. The cardiac output of the pig measured using MRI was in close agreement with the thermodilution measurements.
Conclusions Our new method of measuring valvular regurgitation has been shown to be very accurate in vitro and in vivo and therefore is a potentially accurate way to quantify valvular regurgitation.
Key Words: valves regurgitation magnetic resonance imaging
This article has been cited by other articles:
![]() |
2006 WRITING COMMITTEE MEMBERS, R. O. Bonow, B. A. Carabello, K. Chatterjee, A. C. de Leon Jr, D. P. Faxon, M. D. Freed, W. H. Gaasch, B. W. Lytle, R. A. Nishimura, et al. 2008 Focused Update Incorporated Into the ACC/AHA 2006 Guidelines for the Management of Patients With Valvular Heart Disease: A Report of the American College of Cardiology/American Heart Association Task Force on Practice Guidelines (Writing Committee to Revise the 1998 Guidelines for the Management of Patients With Valvular Heart Disease): Endorsed by the Society of Cardiovascular Anesthesiologists, Society for Cardiovascular Angiography and Interventions, and Society of Thoracic Surgeons Circulation, October 7, 2008; 118(15): e523 - e661. [Full Text] [PDF] |
||||
![]() |
R. O. Bonow, B. A. Carabello, K. Chatterjee, A. C. de Leon Jr, D. P. Faxon, M. D. Freed, W. H. Gaasch, B. W. Lytle, R. A. Nishimura, P. T. O'Gara, et al. 2008 Focused Update Incorporated Into the ACC/AHA 2006 Guidelines for the Management of Patients With Valvular Heart Disease: A Report of the American College of Cardiology/American Heart Association Task Force on Practice Guidelines (Writing Committee to Revise the 1998 Guidelines for the Management of Patients With Valvular Heart Disease) Endorsed by the Society of Cardiovascular Anesthesiologists, Society for Cardiovascular Angiography and Interventions, and Society of Thoracic Surgeons J. Am. Coll. Cardiol., September 23, 2008; 52(13): e1 - e142. [Full Text] [PDF] |
||||
![]() |
R. O. Bonow, B. A. Carabello, K. Chatterjee, A. C. de Leon Jr, D. P. Faxon, M. D. Freed, W. H. Gaasch, B. W. Lytle, R. A. Nishimura, P. T. O'Gara, et al. ACC/AHA 2006 Guidelines for the Management of Patients With Valvular Heart Disease: A Report of the American College of Cardiology/American Heart Association Task Force on Practice Guidelines (Writing Committee to Revise the 1998 Guidelines for the Management of Patients With Valvular Heart Disease) Developed in Collaboration With the Society of Cardiovascular Anesthesiologists Endorsed by the Society for Cardiovascular Angiography and Interventions and the Society of Thoracic Surgeons J. Am. Coll. Cardiol., August 1, 2006; 48(3): e1 - e148. [Full Text] [PDF] |
||||
![]() |
J. Albers, T. Nitsche, J. Boese, R. De Simone, I. Wolf, A. Schroeder, and C. F. Vahl Regurgitant jet evaluation using three-dimensional echocardiography and magnetic resonance Ann. Thorac. Surg., July 1, 2004; 78(1): 96 - 102. [Abstract] [Full Text] [PDF] |
||||
![]() |
S. Oyre, S. Ringgaard, S. Kozerke, W. P. Paaske, M. Erlandsen, P. Boesiger, and E. M. Pedersen Accurate noninvasive quantitation of blood flow, cross-sectional lumen vessel area and wall shear stress by three-dimensional paraboloid modeling of magnetic resonance imaging velocity data J. Am. Coll. Cardiol., July 1, 1998; 32(1): 128 - 134. [Abstract] [Full Text] [PDF] |
||||
![]() |
P. A. Grayburn and R. M. Peshock Noninvasive Quantification of Valvular Regurgitation: Getting to the Core of the Matter Circulation, July 15, 1996; 94(2): 119 - 121. [Full Text] |
||||
|
Circulation Home | Subscriptions | Archives | Feedback | Authors | Help | AHA Journals Home | Search Copyright © 1995 American Heart Association, Inc. All rights reserved. Unauthorized use prohibited. |