Donate Help Contact The AHA Sign In Home
American Heart Association
Circulation
Search: search_blue_button Advanced Search
Circulation. 1992;86:1836-1844

This Article
Right arrow Full Text (PDF)
Right arrow Alert me when this article is cited
Right arrow Alert me if a correction is posted
Right arrow Citation Map
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Download to citation manager
Right arrowRequest Permissions
Citing Articles
Right arrow Citing Articles via HighWire
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Ellis, S. G.
Right arrow Articles by Walker, C.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Ellis, S. G.
Right arrow Articles by Walker, C.

Circulation, Vol 86, 1836-1844, Copyright © 1992 by American Heart Association


ARTICLES

Restenosis after placement of Palmaz-Schatz stents in native coronary arteries. Initial results of a multicenter experience

SG Ellis, M Savage, D Fischman, DS Baim, M Leon, S Goldberg, JW Hirshfeld, MW Cleman, PS Teirstein and C Walker
University of Michigan Medical Center, Ann Arbor.

BACKGROUND. Several metallic intracoronary stents are currently undergoing preliminary evaluation to ascertain potential benefit as means to reduce the 30-40% incidence of restenosis after balloon angioplasty. METHODS AND RESULTS. To determine the incidence and correlates of restenosis after placement of Palmaz-Schatz stents in native coronary arteries in the first group of patients selected for this procedure, clinical and quantitative angiographic data from 206 consecutive patients (221 stenoses) with successful stent placement (diameter stenosis < 50%) were analyzed. Six patients (2.9%) had thrombosis-mediated stent closure within 1 month after stent placement and were excluded from long-term angiographic follow-up. One hundred eighty-one (91%) of the remaining 200 patients had angiography at 5.8 +/- 2.1 months. Patients with and without follow-up did not differ in any baseline characteristic; in particular, history of restenosis at the site stented (73% versus 65%), placement of multiple overlapping stents (17% versus 20%), and mean poststent diameter stenosis (16 +/- 12% versus 14 +/- 12%). The overall incidence of restenosis (diameter stenosis > or = 50% at follow-up) in this group at high risk for restenosis was 36% (95% confidence interval, 29-43%) on a per-stenosis basis. The incidence of restenosis when a single stent was placed was 30% (95% confidence interval, 23-37%). Risk was dependent upon a history of restenosis (present versus absent 36% versus 16%, p = 0.02) and upon whether or not a poststent stenosis < or = 0% was achieved (6% versus 33%, p = 0.02). When multiple overlapping stents were placed, restenosis occurred at 64% of sites, and placement of multiple stents was discouraged during the later phases of this study as these results became apparent. CONCLUSIONS. Although multiple stents appear to yield a poor long-term result, placement of single stents may offer a benefit compared with standard coronary angioplasty, particularly if an excellent angiographic result can be obtained in patients without prior restenosis. Further randomized trials in such patients are needed.


This article has been cited by other articles:


Home page
ANGIOLOGYHome page
Qiangjun Cai, K. Skelding, A. Armstrong Jr, D. Desai, G. C. Wood, and J. Blankenship
Predictors of Long-Term Major Adverse Cardiac Events and Clinical Restenosis Following Elective Percutaneous Coronary Stenting
Angiology, April 1, 2009; 60(2): 141 - 147.
[Abstract] [PDF]


Home page
Arterioscler. Thromb. Vasc. Bio.Home page
Z. A. Ali, N. J. Alp, H. Lupton, N. Arnold, T. Bannister, Y. Hu, S. Mussa, M. Wheatcroft, D. R. Greaves, J. Gunn, et al.
Increased In-Stent Stenosis in ApoE Knockout Mice: Insights from a Novel Mouse Model of Balloon Angioplasty and Stenting
Arterioscler Thromb Vasc Biol, April 1, 2007; 27(4): 833 - 840.
[Abstract] [Full Text] [PDF]


Home page
J Am Coll CardiolHome page
D. J. Kereiakes, H. Wang, J. J. Popma, R. E. Kuntz, D. J. Donohoe, J. Schofer, E. Schampaert, B. Meier, M. B. Leon, and J. W. Moses
Periprocedural and Late Consequences of Overlapping Cypher Sirolimus-Eluting Stents: Pooled Analysis of Five Clinical Trials
J. Am. Coll. Cardiol., July 4, 2006; 48(1): 21 - 31.
[Abstract] [Full Text] [PDF]


Home page
HeartHome page
M Albertal, G Van Langenhove, E Regar, I P Kay, D Foley, G Sianos, K Kozuma, T Beijsterveldt, S G Carlier, J A Belardi, et al.
Uncomplicated moderate coronary artery dissections after balloon angioplasty: good outcome without stenting
Heart, August 1, 2001; 86(2): 193 - 198.
[Abstract] [Full Text] [PDF]


Home page
J Am Coll CardiolHome page
S. C. Smith Jr, J. T. Dove, A. K. Jacobs, J. Ward Kennedy, D. Kereiakes, M. J. Kern, R. E. Kuntz, J. J. Popma, H. V. Schaff, D. O. Williams, et al.
ACC/AHA guidelines for percutaneous coronary intervention (revision of the 1993 PTCA guidelines): A report of the American College of Cardiology/ American Heart Association Task Force on practice guidelines (Committee to revise the 1993 guidelines for percutaneous transluminal coronary angioplasty) endorsed by the Society for Cardiac Angiography and Interventions
J. Am. Coll. Cardiol., June 15, 2001; 37(8): 2239 - 2239.
[Full Text] [PDF]


Home page
Eur Heart JHome page
F Schiele, N Meneveau, M.-F Seronde, M.-F Deforet, S Gupta, and J.-P Bassand
Predictors of event-free survival after repeat intracoronary procedure for in-stent restenosis. Study with angiographic and intravascular ultrasound imaging
Eur. Heart J., May 1, 2000; 21(9): 754 - 762.
[Abstract] [PDF]


Home page
J Am Coll CardiolHome page
M. Gyongyosi, P. Yang, A. Khorsand, D. Glogar, on behalf of the Austrian Wiktor Stent Study Group, and European Paragon Stent Investigators
Longitudinal straightening effect of stents is an additional predictor for major adverse cardiac events
J. Am. Coll. Cardiol., May 1, 2000; 35(6): 1580 - 1589.
[Abstract] [Full Text] [PDF]


Home page
J Am Coll CardiolHome page
R. Kornowski, B. Bhargava, D. M. S. Fuchs, A. J. Lansky, L. F. Satler, A. D. Pichard, M. K. Hong, K. M. Kent, R. Mehran, G. W. Stone, et al.
Procedural results and late clinical outcomes after percutaneous interventions using long (>=25 mm) versus short (<20 mm) stents
J. Am. Coll. Cardiol., March 1, 2000; 35(3): 612 - 618.
[Abstract] [Full Text] [PDF]


Home page
J Am Coll CardiolHome page
L. Gruberg, R. Mehran, G. Dangas, M. K. Hong, G. S. Mintz, R. Kornowski, A. J. Lansky, K. M. Kent, A. D. Pichard, L. F. Satler, et al.
Effect of plaque debulking and stenting on short- and long-term outcomes after revascularization of chronic total occlusions
J. Am. Coll. Cardiol., January 1, 2000; 35(1): 151 - 156.
[Abstract] [Full Text] [PDF]


Home page
J Am Coll CardiolHome page
P. R. Moreno, J. T. Fallon, A. M. Murcia, M. N. Leon, H. Simosa, V. Fuster, and I. F. Palacios
Tissue characteristics of restenosis after percutaneous transluminal coronary angioplasty in diabetic patients
J. Am. Coll. Cardiol., October 1, 1999; 34(4): 1045 - 1049.
[Abstract] [Full Text] [PDF]


Home page
J Am Coll CardiolHome page
P. W. Serruys, I. P. Kay, C. Disco, N. V. Deshpande, P. J. de Feyter, and on behalf of the BENESTENT I BENESTENT II Pilot BE
Periprocedural quantitative coronary angiography after Palmaz-Schatz stent implantation predicts the restenosis rate at six months: Results of a meta-analysis of the belgian netherlands stent study (BENESTENT) I, BENESTENT II pilot, BENESTENT II and MUSIC trials
J. Am. Coll. Cardiol., October 1, 1999; 34(4): 1067 - 1074.
[Abstract] [Full Text] [PDF]


Home page
J Am Coll CardiolHome page
Y. Kobayashi, J. De Gregorio, N. Kobayashi, T. Akiyama, B. Reimers, L. Finci, C. Di Mario, and A. Colombo
Stented segment length as an independent predictor of restenosis
J. Am. Coll. Cardiol., September 1, 1999; 34(3): 651 - 659.
[Abstract] [Full Text] [PDF]


Home page
Eur Heart JHome page
J. Schofer, T. Rau, M. Schluter, and D.G. Mathey
Restenosis after stenting of matched occluded and non-occluded coronary arteries. Should there be a difference?
Eur. Heart J., August 2, 1999; 20(16): 1175 - 1181.
[Abstract] [PDF]


Home page
NEJMHome page
R. Erbel, M. Haude, H. W. Hopp, D. Franzen, H. J. Rupprecht, B. Heublein, K. Fischer, P. de Jaegere, P. Serruys, W. Rutsch, et al.
Coronary-Artery Stenting Compared with Balloon Angioplasty for Restenosis after Initial Balloon Angioplasty
N. Engl. J. Med., December 3, 1998; 339(23): 1672 - 1678.
[Abstract] [Full Text] [PDF]


Home page
J Am Coll CardiolHome page
S. Elezi, A. Kastrati, J.u. Pache, A. Wehinger, M. Hadamitzky, J. Dirschinger, F.-J. Neumann, and A. Schomig
Diabetes mellitus and the clinical and angiographic outcome after coronary stent placement
J. Am. Coll. Cardiol., December 1, 1998; 32(7): 1866 - 1873.
[Abstract] [Full Text] [PDF]


Home page
J Am Coll CardiolHome page
T. Akiyama, I. Moussa, B. Reimers, M. Ferraro, Y. Kobayashi, S. Blengino, L. Di Francesco, L. Finci, C. Di Mario, and A. Colombo
Angiographic and clinical outcome following coronary stenting of small vessels: A comparison with coronary stenting of large vessels
J. Am. Coll. Cardiol., November 15, 1998; 32(6): 1610 - 1618.
[Abstract] [Full Text] [PDF]


Home page
J Am Coll CardiolHome page
S. Kasaoka, J. M. Tobis, T. Akiyama, B. Reimers, C. Di Mario, N. D. Wong, and A. Colombo
Angiographic and intravascular ultrasound predictors of in-stent restenosis
J. Am. Coll. Cardiol., November 15, 1998; 32(6): 1630 - 1635.
[Abstract] [Full Text] [PDF]


Home page
CirculationHome page
S. Elezi, A. Kastrati, F.-J. Neumann, M. Hadamitzky, J. Dirschinger, and A. Schomig
Vessel Size and Long-Term Outcome After Coronary Stent Placement
Circulation, November 3, 1998; 98(18): 1875 - 1880.
[Abstract] [Full Text] [PDF]


Home page
VASC ENDOVASCULAR SURGHome page
J. S. Munn, K. M. Jain, and E. J. Simoni
Reoperation for Recurrent Carotid Stenosis: A Ten-Year Experience
Vascular and Endovascular Surgery, September 1, 1998; 32(5): 425 - 432.
[Abstract] [PDF]


Home page
CirculationHome page
R. Kornowski, R. Mehran, M. K. Hong, L. F. Satler, A. D. Pichard, K. M. Kent, G. S. Mintz, R. Waksman, J. R. Laird, A. J. Lansky, et al.
Procedural Results and Late Clinical Outcomes After Placement of Three or More Stents in Single Coronary Lesions
Circulation, April 14, 1998; 97(14): 1355 - 1361.
[Abstract] [Full Text] [PDF]


Home page
HeartHome page
C di Mario, B Reimers, Y Almagor, I Moussa, L Di Francesco, M Ferraro, M B Leon, K Richter, and A Colombo
Procedural and follow up results with a new balloon expandable stent in unselected lesions
Heart, March 1, 1998; 79(3): 234 - 241.
[Abstract] [Full Text]


Home page
HeartHome page
A. Chauhan, E. Vu, D. R Ricci, C. E Buller, M. D Moscovich, S. Monkman, and I. M Penn
Early and intermediate term clinical outcome after multiple coronary stenting
Heart, January 1, 1998; 79(1): 29 - 33.
[Abstract] [Full Text] [PDF]


Home page
CirculationHome page
A. Schomig, A. Kastrati, S. Elezi, H. Schuhlen, J. Dirschinger, F. Dannegger, M. Wilhelm, and K. Ulm
Bimodal Distribution of Angiographic Measures of Restenosis Six Months After Coronary Stent Placement
Circulation, December 2, 1997; 96(11): 3880 - 3887.
[Abstract] [Full Text]


Home page
NEJMHome page
M. P. Savage, J. S. Douglas, D. L. Fischman, C. J. Pepine, S. B. King, J. A. Werner, S. R. Bailey, P. A. Overlie, S. H. Fenton, J. A. Brinker, et al.
Stent Placement Compared with Balloon Angioplasty for Obstructed Coronary Bypass Grafts
N. Engl. J. Med., September 11, 1997; 337(11): 740 - 747.
[Abstract] [Full Text] [PDF]


Home page
CirculationHome page
E. Van Belle, C. Bauters, E. Hubert, J.-C. Bodart, K. Abolmaali, T. Meurice, E. P. McFadden, J.-M. Lablanche, and M. E. Bertrand
Restenosis Rates in Diabetic Patients : A Comparison of Coronary Stenting and Balloon Angioplasty in Native Coronary Vessels
Circulation, September 2, 1997; 96(5): 1454 - 1460.
[Abstract] [Full Text]


Home page
CirculationHome page
I. Moussa, C. Di Mario, J. Moses, B. Reimers, L. Di Francesco, G. Martini, J. Tobis, and A. Colombo
Coronary Stenting After Rotational Atherectomy in Calcified and Complex Lesions : Angiographic and Clinical Follow-Up Results
Circulation, July 1, 1997; 96(1): 128 - 136.
[Abstract] [Full Text]


Home page
Ann. Thorac. Surg.Home page
E. A. Tovar and A. Borsari
Effects of Surgical Manipulation on Coronary Stents: Should Surgical Strategy Be Altered?
Ann. Thorac. Surg., January 1, 1997; 63(1): 37 - 40.
[Abstract] [Full Text]


Home page
NEJMHome page
T. Kimura, H. Yokoi, Y. Nakagawa, T. Tamura, S. Kaburagi, Y. Sawada, Y. Sato, H. Yokoi, N. Hamasaki, H. Nosaka, et al.
Three-Year Follow-Up after Implantation of Metallic Coronary-Artery Stents
N. Engl. J. Med., February 29, 1996; 334(9): 561 - 567.
[Abstract] [Full Text] [PDF]


Home page
CirculationHome page
C. Rogers and E. R. Edelman
Endovascular Stent Design Dictates Experimental Restenosis and Thrombosis
Circulation, June 15, 1995; 91(12): 2995 - 3001.
[Abstract] [Full Text]


Home page
Arterioscler. Thromb. Vasc. Bio.Home page
G. L. Nunes, D. S. Sgoutas, R. A. Redden, S. R. Sigman, M. B. Gravanis, S. B. King III, and B. C. Berk
Combination of Vitamins C and E Alters the Response to Coronary Balloon Injury in the Pig
Arterioscler Thromb Vasc Biol, January 1, 1995; 15(1): 156 - 165.
[Abstract] [Full Text]


Home page
NEJMHome page
D. L. Fischman, M. B. Leon, D. S. Baim, R. A. Schatz, M. P. Savage, I. Penn, K. Detre, L. Veltri, D. Ricci, M. Nobuyoshi, et al.
A Randomized Comparison of Coronary-Stent Placement and Balloon Angioplasty in the Treatment of Coronary Artery Disease
N. Engl. J. Med., August 25, 1994; 331(8): 496 - 501.
[Abstract] [Full Text]


Home page
NEJMHome page
E. J. Topol
Caveats about Elective Coronary Stenting
N. Engl. J. Med., August 25, 1994; 331(8): 539 - 541.
[Full Text]


Home page
NEJMHome page
J. A. Bittl
Directional Coronary Atherectomy versus Balloon Angioplasty
N. Engl. J. Med., July 22, 1993; 329(4): 273 - 274.
[Full Text]