Donate Help Contact The AHA Sign In Home
American Heart Association
Circulation
Search: search_blue_button Advanced Search
Circulation. 1991;83:304-314

This Article
Right arrow Full Text (PDF)
Right arrow Alert me when this article is cited
Right arrow Alert me if a correction is posted
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Download to citation manager
Right arrowRequest Permissions
Citing Articles
Right arrow Citing Articles via HighWire
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Starling, M. R.
Right arrow Articles by Gross, M. D.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Starling, M. R.
Right arrow Articles by Gross, M. D.
Right arrowPubmed/NCBI databases
*Compound via MeSH
*Substance via MeSH

Circulation, Vol 83, 304-314, Copyright © 1991 by American Heart Association


ARTICLES

Relation between maximum time-varying elastance pressure-volume areas and myocardial oxygen consumption in dogs

MR Starling, GB Mancini, DG Montgomery and MD Gross
Department of Internal Medicine, University of Michigan, Ann Arbor 48105.

To establish whether pressure-volume areas (PVAs) calculated using the maximum time-varying elastance (Emax) have a relation with myocardial oxygen consumption (MVO2) that improves on other indexes of myocardial oxygen demand, we studied nine dogs of either sex weighing 19-39 kg, which were instrumented with a micromanometer left ventricular (LV) catheter and a Wilton-Webster coronary sinus flow catheter and had red blood cells tagged with technetium-99m for radionuclide angiography. Hemodynamics, coronary sinus flow determinations, and radionuclide angiograms were obtained under control conditions and during three to five steady-state loading conditions (mean +/- SD, 5.6 +/- 0.7). Isochronal pressure-volume data points from each pressure-volume loop were subjected to linear regression analysis to calculate Emax. The Emax relations, diastolic curves, and systolic portions of each pressure-volume loop were used to obtain calibrated PVAs. The Emax PVA (mm Hg.ml.beat-1.100 g-1) and MVO2 (ml O2.beat-1.100 g-1) values correlated in each animal (r = 0.77 to 0.99). Their slopes averaged (3.48 +/- 1.68) x 10(-5) ml O2.mm Hg-1.ml-1, and their y-axis intercepts averaged 0.07 +/- 0.04 ml O2.beat-1.100 g-1. When the MVO2 relations were compared with Emax PVA, LV systolic pressure-rate product, LV stroke work, and a modification of the LV pressure-work index, the Emax PVA, LV systolic pressure-rate product, and LV pressure- work index had similar relations with MVO2, whereas LV stroke work was a weaker index of MVO2 (p less than 0.05 versus Emax PVA). This occurred because the Emax PVA:MVO2 slopes and y-axis intercepts differed in each dog, which was due to differences in basal LV contractility. The Emax PVA:MVO2 slopes correlated with Emax (r = 0.73, p less than 0.05), and the y-axis intercepts were also weakly related to Emax (r = 0.48, p = 0.19). We conclude that the Emax PVAs calculated using data acquisition techniques that are clinically applicable have relations with MVO2 that in general do not improve on other indexes of myocardial oxygen demand in this animal preparation.


This article has been cited by other articles:


Home page
Ann. Thorac. Surg.Home page
K. Shirota, Y. Huang, O. Kawaguchi, T. Yuasa, P. W. Brady, Y. Ueda, and S. N. Hunyor
Functional recovery of the native heart after cardiomyoplasty in sheep with heart failure: passive and dynamic effects of volume loading
Ann. Thorac. Surg., March 1, 2002; 73(3): 849 - 854.
[Abstract] [Full Text] [PDF]