Donate Help Contact The AHA Sign In Home
American Heart Association
Circulation
Search: search_blue_button Advanced Search
Circulation. 1985;71:579-586

This Article
Right arrow Full Text (PDF)
Right arrow Alert me when this article is cited
Right arrow Alert me if a correction is posted
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Download to citation manager
Right arrow Request Permissions
Citing Articles
Right arrow Citing Articles via HighWire
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Lee, B. I.
Right arrow Articles by Ferrans, V. J.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Lee, B. I.
Right arrow Articles by Ferrans, V. J.

Circulation, Vol 71, 579-586, Copyright © 1985 by American Heart Association


ARTICLES

Transcatheter ablation: comparison between laser photoablation and electrode shock ablation in the dog

BI Lee, JS Gottdiener, RD Fletcher, ER Rodriguez and VJ Ferrans

To characterize and compare the effects of transcatheter laser and electrical energy on endocardium, 35 laser pulses were delivered to the endocardial surfaces of isolated canine hearts, and 33 endocardial lesions were produced by the transarterial delivery of either transcatheter laser irradiation or electrical shock in closed-chest anesthetized dogs. Laser-induced lesion dimensions in vitro and in vivo increased with increased total dose of energy; however, the lesions produced in vivo were different in morphology and were significantly larger than lesions produced by equivalent doses of energy delivered in vitro (p less than .05). Endocardial lesions produced in vivo by laser at 40 and 80 J (7.9 X 5.4 X 6.6 and 7.9 X 5.1 X 7.5 mm) were comparable in gross morphology and size to those produced by electrical shock at 100 and 200 J (8.5 X 6.6 X 6.6 and 10.0 X 8.5 X 8.2 mm, respectively; p = NS), but transcatheter electrode shock produced significantly more ventricular tachycardia (p less than .003), premature ventricular beats in the 7 min after energy discharge (p less than .05), and wall motion abnormality (p less than .005). Transcatheter laser photoablation can create controlled endocardial lesions with less energy and fewer deleterious effects than transcatheter electrode shock.


This article has been cited by other articles:


Home page
CirculationHome page
D. L. Ware, P. Boor, C. Yang, A. Gowda, J. J. Grady, and M. Motamedi
Slow Intramural Heating With Diffused Laser Light : A Unique Method for Deep Myocardial Coagulation
Circulation, March 30, 1999; 99(12): 1630 - 1636.
[Abstract] [Full Text] [PDF]


Home page
CirculationHome page
A. Goette, W. Hartung, M. Lesh, C. Honeycutt, S. Fleischman, D. Swanson, and J. Langberg
Transcatheter Subendocardial Infusion: A Novel Technique for Mapping and Ablation of Ventricular Myocardium
Circulation, September 15, 1996; 94(6): 1449 - 1455.
[Abstract] [Full Text]


Home page
J. Thorac. Cardiovasc. Surg.Home page
L. L. Mickleborough, S. Mizuno, A. Usui, G. Wilson, D. McComb, and G. Gray
Balloon electric shock ablation--A surgical technique for treatment of ventricular tachycardia: Influence of endocardial scar on depth of ablation achieved
J. Thorac. Cardiovasc. Surg., November 1, 1994; 108(5): 855 - 861.
[Abstract] [Full Text]