Donate Help Contact The AHA Sign In Home
American Heart Association
Circulation
Search: search_blue_button Advanced Search
Circulation. 1976;54:729-737

This Article
Right arrow Full Text (PDF)
Right arrow Alert me when this article is cited
Right arrow Alert me if a correction is posted
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Download to citation manager
Right arrowRequest Permissions
Citing Articles
Right arrow Citing Articles via HighWire
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Laniado, S.
Right arrow Articles by Stadler, J.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Laniado, S.
Right arrow Articles by Stadler, J.

Circulation, Vol 54, 729-737, Copyright © 1976 by American Heart Association


ARTICLES

Hemodynamic correlates of the normal aortic valve echogram. A study of sound, flow, and motion

S Laniado, E Yellin, R Terdiman, I Meytes and J Stadler

The aortic valve echogram was recorded in open chest dogs simultaneously with aortic flow, acceleration of flow, aortic and left ventricular pressures, and intracardiac phonocardiograms. Comparison of echographic with hemodynamic data showed the following: The aortic valve started its opening with the onset of flow, at the same point that left ventricular pressure exceeded aortic pressure. Complete valve opening preceded peak aortic flow by an average of 43 msec and the cusps started to move toward closure while flow was still accelerating. Final closure of the valve was achieved at the time of zero flow and preceded the aortic second sound by 4-10 msec. The echographically determined "valve orifice area" correlated well with aortic stroke volume (r = 0.94). The intensity of the aortic first sound was related to peak acceleration of aortic flow. The intensity of the second sound was not related to the amplitude of cusp motion but correlated well with the aortic pressure at the time of closure and with peak flow deceleration.


This article has been cited by other articles:


Home page
CirculationHome page
J. Bermejo, J. L. Rojo-Alvarez, J. C. Antoranz, M. Abel, I. G. Burwash, R. Yotti, M. Moreno, M. A. Garcia-Fernandez, K. G. Lehmann, and C. M. Otto
Estimation of the End of Ejection in Aortic Stenosis: An Unreported Source of Error in the Invasive Assessment of Severity
Circulation, August 31, 2004; 110(9): 1114 - 1120.
[Abstract] [Full Text] [PDF]


Home page
J. Thorac. Cardiovasc. Surg.Home page
M. Higashidate, K. Tamiya, T. Beppu, and Y. Imai
REGULATION OF THE AORTIC VALVE OPENINGIn vivo dynamic measurement of aortic valve orifice area
J. Thorac. Cardiovasc. Surg., August 1, 1995; 110(2): 496 - 503.
[Abstract] [Full Text]


Home page
ANGIOLOGYHome page
C. Veyrat, D. Kalmanson, C. Gourtchiglouian, and M.C. Malergue
Localization of the Origin of Systolic Clicks Using Echo-Pulsed Doppler Technique
Angiology, April 1, 1981; 32(4): 266 - 276.
[Abstract] [PDF]