Donate Help Contact The AHA Sign In Home
American Heart Association
Circulation
Search: search_blue_button Advanced Search
Circulation. 2009;120:1903-1909
Published online before print October 26, 2009, doi: 10.1161/CIRCULATIONAHA.109.880385
This Article
Right arrow Full Text
Right arrow Full Text (PDF)
Right arrow All Versions of this Article:
120/19/1903    most recent
CIRCULATIONAHA.109.880385v1
Right arrow Alert me when this article is cited
Right arrow Alert me if a correction is posted
Right arrow Citation Map
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Download to citation manager
Right arrowRequest Permissions
Citing Articles
Right arrow Citing Articles via HighWire
Google Scholar
Right arrow Articles by Beels, L.
Right arrow Articles by Thierens, H.
PubMed
Right arrow PubMed Citation
Right arrow Articles by Beels, L.
Right arrow Articles by Thierens, H.
Related Collections
Right arrow Pediatric and congenital heart disease, including cardiovascular surgery
Right arrowRelated Articles

(Circulation. 2009;120:1903-1909.)
© 2009 American Heart Association, Inc.


Pediatric Cardiology

{gamma}-H2AX Foci as a Biomarker for Patient X-Ray Exposure in Pediatric Cardiac Catheterization

Are We Underestimating Radiation Risks?

Laurence Beels, MSc; Klaus Bacher, PhD; Daniël De Wolf, MD, PhD; Joke Werbrouck, MSc; Hubert Thierens, PhD

From the University of Ghent, Departments of Basic Medical Sciences (L.B., K.B., J.W., H.T.) and Pediatrics and Genetics (D.D.W.), Gent, Belgium.

Correspondence to Laurence Beels, MSc, Ghent University, Department of Basic Medical Sciences, Proeftuinstraat 86, 9000 Gent, Belgium. E-mail Laurence.Beels{at}UGent.be

Received May 18, 2009; accepted August 24, 2009.

Background— A better knowledge of patient x-ray dose and the associated radiation risk in pediatric interventional cardiology is warranted in view of the extensive use of x-rays and the higher radiosensitivity of children. In the present study, {gamma}-H2AX foci were used as a biomarker for radiation-induced effects. Patient-specific dose was assessed and radiation risks were estimated according to the linear-no-threshold model, commonly used in radiation protection, and the {gamma}-H2AX foci data.

Methods and Results— In 49 pediatric patients (median age, 0.75 years) with congenital heart disease who underwent cardiac catheterization procedures, blood samples were taken before and shortly after the procedure. {gamma}-H2AX foci were determined in peripheral blood T lymphocytes. In each patient, a net increase in {gamma}-H2AX foci, representing DNA double-strand breaks induced by interventional x-rays, was observed. In addition, a patient-specific Monte Carlo simulation of the procedure was performed, resulting in individual blood, organ, and tissue doses. Plotting of {gamma}-H2AX foci versus blood dose indicated a low-dose hypersensitivity. Median effective doses calculated according to the International Commission on Radiological Protection 60 and 103 publications are 5.6 and 6.4 mSv, respectively. The lifetime-attributable risk of cancer mortality was calculated from the linear-no-threshold model and the {gamma}-H2AX foci data. This resulted in lifetime-attributable risk values of 1% and 4%, respectively, for the patient population under study.

Conclusions— {gamma}-H2AX foci as a biomarker for DNA damage indicate that radiation risk estimates according to the linear-no-threshold hypothesis are possibly underestimates. Great care should be taken to minimize and optimize patient radiation exposure.


 

CLINICAL PERSPECTIVE


Related Articles:

Clinical Summaries
Circulation 2009 120: 1843-1844. [Extract] [Full Text]

Radiation Risk From Pediatric Cardiac Catheterization: Friendly Fire on Children With Congenital Heart Disease
Maria Grazia Andreassi
Circulation 2009 120: 1847-1849. [Extract] [Full Text]



This article has been cited by other articles:


Home page
CirculationHome page
M. G. Andreassi
Radiation Risk From Pediatric Cardiac Catheterization: Friendly Fire on Children With Congenital Heart Disease
Circulation, November 10, 2009; 120(19): 1847 - 1849.
[Full Text] [PDF]