(Circulation. 2008;117:2752-2760.)
© 2008 American Heart Association, Inc.
Interventional Cardiology |
From the University of Toledo, Toledo, Ohio (C.J.C., S.T.H., W.C., M.W.B., P.B., M.A.A., D.J.K., J.I.S., S.K.); University of Minnesota, Minneapolis (M.S.); PIMA Cardiovascular, Tucson, Ariz (W.J.T.); William Beaumont Hospital, Royal Oak, Mich (R.S.); Fuqua Heart Center, Atlanta, Ga (B.R.); CVPath Institute, Gaithersburg, Md (R.V.); Midwest Cardiovascular Research, Davenport, Iowa (E.D.); Prairie Cardiovascular, Peoria, Ill (K.R.-S.); Brown University, Providence, RI (T.P.M.); and Boston University, Boston, Mass (R.D.D., M.J.P.).
Correspondence to Christopher J. Cooper, MD, Professor of Medicine, Chief, Cardiovascular Division, University of Toledo, 3000 Arlington Ave, MS 1036, Toledo, OH 43614. E-mail Christopher.cooper{at}utoledo.edu
Received August 20, 2007; accepted March 5, 2008.
Background— Preservation of renal function is an important objective of renal artery stent procedures. Although atheroembolization can cause renal dysfunction during renal stent procedures, whether adjunctive use of embolic protection devices or glycoprotein IIb/IIIa inhibitors improves renal function is unknown.
Methods and Results— One hundred patients undergoing renal artery stenting at 7 centers were randomly assigned to an open-label embolic protection device, Angioguard, or double-blind use of a platelet glycoprotein IIb/IIIa inhibitor, abciximab, in a 2x2 factorial design. The main effects of treatments and their interaction were assessed on percentage change in Modification in Diet in Renal Disease–derived glomerular filtration rate from baseline to 1 month using centrally analyzed creatinine. Filter devices were analyzed for the presence of platelet-rich thrombus. With stenting alone, stenting and embolic protection, and stenting with abciximab alone, glomerular filtration rate declined (P<0.05), but with combination therapy, it did not decline and was superior to the other allocations in the 2x2 design (P<0.01). The main effects of treatment demonstrated no overall improvement in glomerular filtration rate; although abciximab was superior to placebo (0±27% versus –10±20%; P<0.05), embolic protection was not (–1±28% versus –10±20%; P=0.08). An interaction was observed between abciximab and embolic protection (P<0.05), favoring combination treatment. Abciximab reduced the occurrence of platelet-rich emboli in the filters from 42% to 7% (P<0.01).
Conclusions— Renal artery stenting alone, stenting with embolic protection, and stenting with abciximab were associated with a decline in glomerular filtration rate. An unanticipated interaction between Angioguard and abciximab was seen, with combination therapy better than no treatment or either treatment alone.
This article has been cited by other articles:
![]() |
K. Rosenfield and M. R. Jaff An 82-Year-Old Woman With Worsening Hypertension: Review of Renal Artery Stenosis JAMA, November 5, 2008; 300(17): 2036 - 2044. [Abstract] [Full Text] [PDF] |
||||
![]() |
J. A. Bittl Damage Control for Renal Artery Stenting Circulation, May 27, 2008; 117(21): 2724 - 2726. [Full Text] [PDF] |
||||
|
Circulation Home | Subscriptions | Archives | Feedback | Authors | Help | AHA Journals Home | Search Copyright © 2008 American Heart Association, Inc. All rights reserved. Unauthorized use prohibited. |