| ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
(Circulation. 2006;114:654-661.)
© 2006 American Heart Association, Inc.
Imaging |
From the University of Chicago, Chicago, Ill (L.S., V.M.-A., L.W., R.M.L.); Public Hospital Elisabethinen, Linz, Austria (J.N., C.E., R.S.-M., H.-J.N.); and TomTec, Unterschleisheim, Germany (F.S., C.G., G.S.).
Correspondence to Lissa Sugeng, MD, University of Chicago, MC5084, 5841 S Maryland Ave, Chicago, IL 60637. E-mail lsugeng{at}medicine.bsd.uchicago.edu
Received March 9, 2006; revision received June 13, 2006; accepted June 14, 2006.
Background Cardiac CT (CCT) and real-time 3D echocardiography (RT3DE) are being used increasingly in clinical cardiology. CCT offers superb spatial and contrast resolution, resulting in excellent endocardial definition. RT3DE has the advantages of low cost, portability, and live 3D imaging without offline reconstruction. We sought to compare both CCT and RT3DE measurements of left ventricular size and function with the standard reference technique, cardiac MR (CMR).
Methods and Results In 31 patients, RT3DE data sets (Philips 7500) and long-axis CMR (Siemens, 1.5 T) and CCT (Toshiba, 16-slice MDCT) images were obtained on the same day without ß-blockers. All images were analyzed to obtain end-systolic and end-diastolic volumes and ejection fractions using the same rotational analysis to eliminate possible analysis-related differences. Intertechnique agreement was tested through linear regression and Bland-Altman analyses. Repeated measurements were performed to determine intraobserver and interobserver variability. Both CCT and RT3DE measurements resulted in high correlation (r2>0.85) compared with CMR. However, CCT significantly overestimated end-diastolic and end-systolic volumes (26 and 19 mL; P<0.05), resulting in a small but significant bias in ejection fraction (2.8%). RT3DE underestimated end-diastolic and end-systolic volumes only slightly (5 and 6 mL), with no significant bias in EF (0.3%; P=0.68). The limits of agreement with CMR were comparable for the 2 techniques. The variability in the CCT measurements was roughly half of that in either RT3DE or CMR values.
Conclusions CCT provides highly reproducible measurements of left ventricular volumes, which are significantly larger than CMR values. RT3DE measurements compared more favorably with the CMR reference, albeit with higher variability.
This article has been cited by other articles:
![]() |
R. C. Cury, K. Nieman, M. D. Shapiro, J. Butler, C. H. Nomura, M. Ferencik, U. Hoffmann, S. Abbara, D. S. Jassal, T. Yasuda, et al. Comprehensive Assessment of Myocardial Perfusion Defects, Regional Wall Motion, and Left Ventricular Function by Using 64-Section Multidetector CT Radiology, August 1, 2008; 248(2): 466 - 475. [Abstract] [Full Text] [PDF] |
||||
![]() |
A-C Pouleur, J-B le Polain de Waroux, A Pasquet, B L Gerber, O Gerard, P Allain, and J-L J Vanoverschelde Assessment of left ventricular mass and volumes by three-dimensional echocardiography in patients with or without wall motion abnormalities: comparison against cine magnetic resonance imaging Heart, August 1, 2008; 94(8): 1050 - 1057. [Abstract] [Full Text] [PDF] |
||||
![]() |
S. De Castro, F. Faletra, E. Di Angelantonio, C. Conca, A. Marcantonio, M. Francone, D. Cartoni, F. Mirabelli, C. Gaudio, S. Caselli, et al. Tomographic Left Ventricular Volumetric Emptying Analysis by Real-Time 3-Dimensional Echocardiography: Influence of Left Ventricular Dysfunction With and Without Electrical Dyssynchrony Circ Cardiovasc Imaging, July 1, 2008; 1(1): 41 - 49. [Abstract] [Full Text] [PDF] |
||||
![]() |
V. Mor-Avi, C. Jenkins, H. P. Kuhl, H.-J. Nesser, T. Marwick, A. Franke, C. Ebner, B. H. Freed, R. Steringer-Mascherbauer, H. Pollard, et al. Real-Time 3-Dimensional Echocardiographic Quantification of Left Ventricular Volumes: Multicenter Study for Validation With Magnetic Resonance Imaging and Investigation of Sources of Error J. Am. Coll. Cardiol. Img., July 1, 2008; 1(4): 413 - 423. [Abstract] [Full Text] [PDF] |
||||
![]() |
W T Roberts, J J Bax, and L C Davies Cardiac CT and CT coronary angiography: technology and application Heart, June 1, 2008; 94(6): 781 - 792. [Abstract] [Full Text] [PDF] |
||||
![]() |
T. Nishikage, H. Nakai, V. Mor-Avi, R. M. Lang, I. S. Salgo, S. H. Settlemier, S. Husson, and M. Takeuchi Quantitative assessment of left ventricular volume and ejection fraction using two-dimensional speckle tracking echocardiography Eur J Echocardiogr, May 13, 2008; (2008) jen166v1. [Abstract] [Full Text] [PDF] |
||||
![]() |
B. D. Soriano, M. Hoch, A. Ithuralde, T. Geva, A. J. Powell, B. D. Kussman, D. A. Graham, W. Tworetzky, and G. R. Marx Matrix-Array 3-Dimensional Echocardiographic Assessment of Volumes, Mass, and Ejection Fraction in Young Pediatric Patients With a Functional Single Ventricle: A Comparison Study With Cardiac Magnetic Resonance Circulation, April 8, 2008; 117(14): 1842 - 1848. [Abstract] [Full Text] [PDF] |
||||
![]() |
N E MANGHAT, V RACHAPALLI, R V. LINGEN, A M VEITCH, C A ROOBOTTOM, and G J MORGAN-HUGHES Imaging the heart valves using ECG-gated 64-detector row cardiac CT Br. J. Radiol., April 1, 2008; 81(964): 275 - 290. [Abstract] [Full Text] [PDF] |
||||
![]() |
J L Hare, C Jenkins, S Nakatani, A Ogawa, C-M Yu, and T H Marwick Feasibility and clinical decision-making with 3D echocardiography in routine practice Heart, April 1, 2008; 94(4): 440 - 445. [Abstract] [Full Text] [PDF] |
||||
![]() |
C M TONGE, R C FERNANDEZ, and M T HARBINSON Current issues in nuclear cardiology Br. J. Radiol., April 1, 2008; 81(964): 270 - 274. [Full Text] [PDF] |
||||
![]() |
K. U. Juergens, H. Seifarth, F. Range, S. Wienbeck, M. Wenker, W. Heindel, and R. Fischbach Automated Threshold-Based 3D Segmentation Versus Short-Axis Planimetry for Assessment of Global Left Ventricular Function with Dual-Source MDCT Am. J. Roentgenol., February 1, 2008; 190(2): 308 - 314. [Abstract] [Full Text] [PDF] |
||||
![]() |
J. N. Kirkpatrick, M. A. Vannan, J. Narula, and R. M. Lang Echocardiography in Heart Failure: Applications, Utility, and New Horizons J. Am. Coll. Cardiol., July 31, 2007; 50(5): 381 - 396. [Abstract] [Full Text] [PDF] |
||||
![]() |
P. B. Mark, R. K. Patel, and A. G. Jardine Are we overestimating left ventricular abnormalities in end-stage renal disease? Nephrol. Dial. Transplant., July 1, 2007; 22(7): 1815 - 1819. [Full Text] [PDF] |
||||
![]() |
R. Olszewski, J. Timperley, S. Cezary, M. Monaghan, P. Nihoyannopoulis, R. Senior, and H. Becher The clinical applications of contrast echocardiography Eur J Echocardiogr, June 1, 2007; 8(3): s13 - s23. [Full Text] [PDF] |
||||
![]() |
T. J. Bunch, S. H. Hohnloser, and B. J. Gersh Mechanisms of Sudden Cardiac Death in Myocardial Infarction Survivors: Insights From the Randomized Trials of Implantable Cardioverter-Defibrillators Circulation, May 8, 2007; 115(18): 2451 - 2457. [Full Text] [PDF] |
||||
![]() |
A. E. Weyman The Year in Echocardiography J. Am. Coll. Cardiol., March 20, 2007; 49(11): 1212 - 1219. [Full Text] [PDF] |
||||
![]() |
P. Knaapen, T. Germans, J. Knuuti, W. J. Paulus, P. A. Dijkmans, C. P. Allaart, A. A. Lammertsma, and F. C. Visser Myocardial Energetics and Efficiency: Current Status of the Noninvasive Approach Circulation, February 20, 2007; 115(7): 918 - 927. [Full Text] [PDF] |
||||
|
Circulation Home | Subscriptions | Archives | Feedback | Authors | Help | AHA Journals Home | Search Copyright © 2006 American Heart Association, Inc. All rights reserved. Unauthorized use prohibited. |