Donate Help Contact The AHA Sign In Home
American Heart Association
Circulation
Search: search_blue_button Advanced Search
Circulation. 2005;111:321-327
Published online before print January 17, 2005, doi: 10.1161/01.CIR.0000153356.72810.97
This Article
Right arrow Full Text
Right arrow Full Text (PDF)
Right arrow Data Supplement
Right arrow All Versions of this Article:
111/3/321    most recent
01.CIR.0000153356.72810.97v1
Right arrow Alert me when this article is cited
Right arrow Alert me if a correction is posted
Right arrow Citation Map
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Download to citation manager
Right arrow Request Permissions
Citing Articles
Right arrow Citing Articles via HighWire
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Mauri, L.
Right arrow Articles by Kuntz, R. E.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Mauri, L.
Right arrow Articles by Kuntz, R. E.
Related Collections
Right arrow Restenosis
Right arrow Catheter-based coronary interventions: stents

(Circulation. 2005;111:321-327.)
© 2005 American Heart Association, Inc.


Interventional Cardiology

Relationship of Late Loss in Lumen Diameter to Coronary Restenosis in Sirolimus-Eluting Stents

Laura Mauri, MD, MSc; E. John Orav, PhD; A. James O’Malley, PhD; Jeffrey W. Moses, MD; Martin B. Leon, MD; David R. Holmes, Jr, MD; Paul S. Teirstein, MD; Joachim Schofer, MD; Günter Breithardt, MD; Donald E. Cutlip, MD; Dean J. Kereiakes, MD; Chunxue Shi, MSc; Brian G. Firth, MD, PhD; Dennis J. Donohoe, MD; Richard E. Kuntz, MD, MSc

From the Brigham and Women’s Hospital (L.M., E.J.O., R.E.K.), Harvard Medical School (A.J.O., L.M., E.J.O., R.E.K., D.E.C.), and Harvard Clinical Research Institute (L.M., R.E.K., D.E.C., C.S.), Boston, Mass; Lenox Hill Heart and Vascular Institute (J.W.M., M.B.L.), New York, NY; Mayo Clinic (D.R.H.), Rochester, Minn; Scripps Clinic (P.S.T.), La Jolla, Calif; Center for Cardiology and Vascular Intervention (J.S.), Hamburg, Germany; Department of Cardiology and Angiology (G.B.), University Hospital, Münster, Germany; Beth Israel Deaconess Medical Center (D.E.C.), Boston, Mass; Ohio Heart Health Center (D.J.K.), Cincinnati, Ohio; and Cordis Corporation (B.G.F., D.J.D.), Warren, NJ.

Correspondence to Richard E. Kuntz, MD, MSc, BC-3-012N, Brigham and Women’s Hospital, 75 Francis St, Boston, MA 02116. E-mail rkuntz{at}partners.org

Received August 2, 2004; revision received September 26, 2004; accepted October 28, 2004.

Background— Observed rates of restenosis after drug-eluting stenting are low (<10%). Identification of a reliable and powerful angiographic end point will be useful in future trials.

Methods and Results— Late loss (postprocedural minimum lumen diameter minus 8-month minimum lumen diameter) was measured in the angiographic cohorts of the SIRIUS (n=703) and E-SIRIUS (n=308) trials. Two techniques, the standard normal approximation and an optimized power transformation, were used to predict binary angiographic restenosis rates and compare them with observed restenosis rates. The mean in-stent late loss observed in the SIRIUS trial was 0.17±0.45 mm (sirolimus) versus 1.00±0.70 mm (control). If a normal distribution was assumed, late loss accurately estimated in-stent binary angiographic restenosis for the control arm (predicted 35.4% versus observed 35.4%) but underestimated it in the sirolimus arm (predicted 0.6% versus observed 3.2%). Power transformation improved the reliability of the estimate in the sirolimus arm (predicted 3.2% [CI 1.0% to 6.7%]) with similar improvements in the E-SIRIUS trial (predicted 4.0% [CI 1.2% to 7.0%] versus observed 3.9%). In the sirolimus-eluting stent arm, in-stent late loss correlated better with target-lesion revascularization than in-segment late loss (c-statistic=0.915 versus 0.665).

Conclusions— Because distributions of late loss with a low mean are right-skewed, the use of a transformation improves the accuracy of predicting low binary restenosis rates. Late loss is monotonically correlated with the probability of restenosis and yields a more efficient estimate of the restenosis process in the era of lower binary restenosis rates.


Key Words: angioplasty • stents • restenosis




This article has been cited by other articles:


Home page
J Am Coll CardiolHome page
S. J. Pocock, A. J. Lansky, R. Mehran, J. J. Popma, M. P. Fahy, Y. Na, G. Dangas, J. W. Moses, T. Pucelikova, D. E. Kandzari, et al.
Angiographic surrogate end points in drug-eluting stent trials: a systematic evaluation based on individual patient data from 11 randomized, controlled trials.
J. Am. Coll. Cardiol., January 1, 2008; 51(1): 23 - 32.
[Abstract] [Full Text] [PDF]


Home page
Diabetes CareHome page
F. Tomai, B. Reimers, L. De Luca, A. R. Galassi, A. Gaspardone, A. S. Ghini, V. Ferrero, L. Favero, G. Gioffre, F. Prati, et al.
Head-to-Head Comparison of Sirolimus- and Paclitaxel-Eluting Stent in the Same Diabetic Patient With Multiple Coronary Artery Lesions: A prospective, randomized, multicenter study
Diabetes Care, January 1, 2008; 31(1): 15 - 19.
[Abstract] [Full Text] [PDF]


Home page
J Am Coll CardiolHome page
D. Baumgart, V. Klauss, F. Baer, F. Hartmann, H. Drexler, W. Motz, H. Klues, S. Hofmann, W. Volker, T. Pfannebecker, et al.
One-Year Results of the SCORPIUS Study: A German Multicenter Investigation on the Effectiveness of Sirolimus-Eluting Stents in Diabetic Patients
J. Am. Coll. Cardiol., October 23, 2007; 50(17): 1627 - 1634.
[Abstract] [Full Text] [PDF]


Home page
CirculationHome page
D. J. Kereiakes, L. Mauri, and R. E. Kuntz
Letter by Kereiakes et al Regarding Article, "Stent Thrombosis Late After Implantation of First-Generation Drug-Eluting Stents: A Cause for Concern"
Circulation, October 16, 2007; 116(16): e389 - e389.
[Full Text] [PDF]


Home page
J Am Coll CardiolHome page
J. Cosgrave, G. Melzi, S. Corbett, G. G.L. Biondi-Zoccai, P. Agostoni, R. Babic, F. Airoldi, A. Chieffo, G. M. Sangiorgi, M. Montorfano, et al.
Comparable Clinical Outcomes With Paclitaxel- and Sirolimus-Eluting Stents in Unrestricted Contemporary Practice
J. Am. Coll. Cardiol., June 19, 2007; 49(24): 2320 - 2328.
[Abstract] [Full Text] [PDF]


Home page
CirculationHome page
K. H. Zou, A. J. O'Malley, and L. Mauri
Receiver-Operating Characteristic Analysis for Evaluating Diagnostic Tests and Predictive Models
Circulation, February 6, 2007; 115(5): 654 - 657.
[Full Text] [PDF]


Home page
NEJMHome page
F. Alfonso, H. Jneid, A. O. Maree, I. F. Palacios, M. Valgimigli, G. Percoco, L. Bolognese, C. Spaulding, P. Henry, E. Teiger, et al.
Drug-eluting stents in primary PCI.
N. Engl. J. Med., December 7, 2006; 355(23): 2483 - 2484.
[Full Text] [PDF]


Home page
J Am Coll CardiolHome page
B. H. Strauss
All Drug-Eluting Stents Are Equal, But Some Drug-Eluting Stents Are More Equal Than Others
J. Am. Coll. Cardiol., October 3, 2006; 48(7): 1310 - 1311.
[Full Text] [PDF]


Home page
J Am Coll CardiolHome page
F. Alfonso, M.-J. Perez-Vizcayno, R. Hernandez, A. Bethencourt, V. Marti, J. R. Lopez-Minguez, J. Angel, R. Mantilla, C. Moris, A. Cequier, et al.
A Randomized Comparison of Sirolimus-Eluting Stent With Balloon Angioplasty in Patients With In-Stent Restenosis: Results of the Restenosis Intrastent: Balloon Angioplasty Versus Elective Sirolimus-Eluting Stenting (RIBS-II) Trial
J. Am. Coll. Cardiol., June 6, 2006; 47(11): 2152 - 2160.
[Abstract] [Full Text] [PDF]


Home page
HeartHome page
R. Seabra-Gomes
Percutaneous coronary interventions with drug eluting stents for diabetic patients.
Heart, March 1, 2006; 92(3): 410 - 419.
[Full Text] [PDF]


Home page
JAMAHome page
M.-C. Morice, A. Colombo, B. Meier, P. Serruys, C. Tamburino, G. Guagliumi, E. Sousa, H.-P. Stoll, and for the REALITY Trial Investigators
Sirolimus- vs Paclitaxel-Eluting Stents in De Novo Coronary Artery Lesions: The REALITY Trial: A Randomized Controlled Trial
JAMA, February 22, 2006; 295(8): 895 - 904.
[Abstract] [Full Text] [PDF]


Home page
JAMAHome page
S. J. Brener
Wish List and REALITY: Choice of Stents and End Points for Treatment of De Novo Coronary Artery Lesions
JAMA, February 22, 2006; 295(8): 937 - 938.
[Full Text] [PDF]


Home page
J Am Coll CardiolHome page
R. Wessely, A. Schomig, and A. Kastrati
Sirolimus and Paclitaxel on Polymer-Based Drug-Eluting Stents: Similar But Different
J. Am. Coll. Cardiol., February 21, 2006; 47(4): 708 - 714.
[Abstract] [Full Text] [PDF]


Home page
HeartHome page
M Thomas
Are drug eluting stents really worth the money?
Heart, January 1, 2006; 92(1): 5 - 7.
[Full Text] [PDF]


Home page
CirculationHome page
L. Mauri, E. J. Orav, S. C. Candia, D. E. Cutlip, and R. E. Kuntz
Robustness of Late Lumen Loss in Discriminating Drug-Eluting Stents Across Variable Observational and Randomized Trials
Circulation, November 1, 2005; 112(18): 2833 - 2839.
[Abstract] [Full Text] [PDF]


Home page
NEJMHome page
A. Dibra, A. Kastrati, J. Mehilli, J. Pache, H. Schuhlen, N. von Beckerath, K. Ulm, R. Wessely, J. Dirschinger, A. Schomig, et al.
Paclitaxel-Eluting or Sirolimus-Eluting Stents to Prevent Restenosis in Diabetic Patients
N. Engl. J. Med., August 18, 2005; 353(7): 663 - 670.
[Abstract] [Full Text] [PDF]


Home page
CirculationHome page
L. Mauri, E. J. Orav, and R. E. Kuntz
Late Loss in Lumen Diameter and Binary Restenosis for Drug-Eluting Stent Comparison
Circulation, June 28, 2005; 111(25): 3435 - 3442.
[Abstract] [Full Text] [PDF]


Home page
CirculationHome page
M. A. Costa and D. I. Simon
Molecular Basis of Restenosis and Drug-Eluting Stents
Circulation, May 3, 2005; 111(17): 2257 - 2273.
[Full Text] [PDF]


Home page
J Am Coll CardiolHome page
D. J. Kereiakes, R. E. Kuntz, L. Mauri, and M. W. Krucoff
Surrogates, substudies, and real clinical end points in trials of drug-eluting stents
J. Am. Coll. Cardiol., April 19, 2005; 45(8): 1206 - 1212.
[Full Text] [PDF]