(Circulation. 2004;110:1114-1120.)
© 2004 American Heart Association, Inc.
Original Articles |
From the Department of Cardiology, Hospital General Universitario Gregorio Marañón, Madrid, Spain (J.B., R.Y., M.M., M.A.G.-F.); Department of Signal Theory and Communications, Universidad Carlos III de Madrid, Madrid, Spain (J.L.R.-A.); Department of Mathematical Physics and Fluids, Facultad de Ciencias, Universidad Nacional de Educación a Distancia, Madrid, Spain (J.C.A.); Division of Cardiology, University of Washington School of Medicine, Veterans Affairs Puget Sound Health Care System, and Providence Health Group, Seattle, Wash (M.A., K.G.L.); University of Ottawa Heart Institute, Ottawa, Ontario, Canada (I.G.B.); and Division of Cardiology, University of Washington, Seattle (C.M.O.).
Correspondence to Javier Bermejo, MD, PhD, Laboratory of Echocardiography, Department of Cardiology, Hospital General Universitario Gregorio Marañón, Dr Esquerdo 46, 28007 Madrid, Spain. E-mail javbermejo{at}jet.es
Received January 31, 2004; revision received March 30, 2004; accepted March 31, 2004.
Background All indices of aortic stenosis (AS) rely on measurements of mean transvalvular pressure gradient (
P) and flow rate. Because the gradient is reversed during late ejection, the late systolic left ventricular (LV)aortic pressure crossover may be an erroneous landmark of end-ejection. The aortic incisura should be a better reference to calculate indices of AS invasively.
Methods and Results The accuracy of the pressure crossover and the incisura to define end-ejection was assessed in a chronic AS experimental model (9 dogs) with the use of an implantable flowmeter and Doppler echocardiography as reference. In 288 hemodynamic recordings analyzed (aortic valve area [AVA]: 0.74±0.46 cm2), ejection ended 37±29 ms after the pressure crossover but almost simultaneously with the incisura (2±17 ms). Pressure crossover error accounted for significant errors in the measurement of
P (95% limits of agreement, +0 to +7 mm Hg) and AVA (0.1 to +0.2 cm2). These errors were reduced to less than half with the use of the incisura to define end-ejection. Additionally, the agreement with Doppler-derived AS indices was best with use of the incisura. Pressure crossover error was maximal in situations of higher output, moderate orifice narrowing, higher arterial compliance, and lower vascular resistance. In 32 consecutive patients undergoing cardiac catheterization for AS, the pressure crossover induced a clinically important overestimation of the
P from +22 to +50%. Errors in AVA estimation were considerably smaller (2% to +6%) because of simultaneous and offsetting errors in the measurements of
P and flow.
Conclusions The aortic incisura and not the second pressure crossover should be used to obtain invasive indices of AS.
Key Words: valves stenosis catheterization hemodynamics animal experimentation
This article has been cited by other articles:
![]() |
C. Blais, I. G. Burwash, G. Mundigler, J. G. Dumesnil, N. Loho, F. Rader, H. Baumgartner, R. S. Beanlands, B. Chayer, L. Kadem, et al. Projected Valve Area at Normal Flow Rate Improves the Assessment of Stenosis Severity in Patients With Low-Flow, Low-Gradient Aortic Stenosis: The Multicenter TOPAS (Truly or Pseudo-Severe Aortic Stenosis) Study Circulation, February 7, 2006; 113(5): 711 - 721. [Abstract] [Full Text] [PDF] |
||||
![]() |
S. H. Rahimtoola The Year in Valvular Heart Disease J. Am. Coll. Cardiol., January 17, 2006; 47(2): 427 - 439. [Full Text] [PDF] |
||||
![]() |
J Jimenez-Candil, J Bermejo, R Yotti, C Cortina, M Moreno, J L Cantalapiedra, and M A Garcia-Fernandez Effects of angiotensin converting enzyme inhibitors in hypertensive patients with aortic valve stenosis: a drug withdrawal study Heart, October 1, 2005; 91(10): 1311 - 1318. [Abstract] [Full Text] [PDF] |
||||
![]() |
R. Yotti, J. Bermejo, M. M. Desco, J. C. Antoranz, J. L. Rojo-Alvarez, C. Cortina, C. Allue, H. Rodriguez-Abella, M. Moreno, and M. A. Garcia-Fernandez Doppler-Derived Ejection Intraventricular Pressure Gradients Provide a Reliable Assessment of Left Ventricular Systolic Chamber Function Circulation, September 20, 2005; 112(12): 1771 - 1779. [Abstract] [Full Text] [PDF] |
||||
![]() |
J Bermejo The effects of hypertension on aortic valve stenosis Heart, March 1, 2005; 91(3): 280 - 282. [Abstract] [Full Text] [PDF] |
||||
|