Donate Help Contact The AHA Sign In Home
American Heart Association
Circulation
Search: search_blue_button Advanced Search
Circulation. 2003;108:II-272-II-277
doi: 10.1161/01.cir.0000087387.02218.7e
This Article
Right arrow Full Text
Right arrow Full Text (PDF)
Right arrow Alert me when this article is cited
Right arrow Alert me if a correction is posted
Right arrow Citation Map
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Download to citation manager
Right arrow Request Permissions
Citing Articles
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Goldstein, D. J.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Goldstein, D. J.

(Circulation. 2003;108:II-272.)
© 2003 American Heart Association, Inc.


Mechanical Circulatory Support

Worldwide Experience With the MicroMed DeBakey Ventricular Assist Device® as a Bridge to Transplantation

Daniel J. Goldstein, MD*

From the Department of Cardiothoracic Surgery, Newark Beth Israel Medical Center, Newark, NJ.

Correspondence to Daniel J. Goldstein, MD, Department of Cardiothoracic Surgery, Newark Beth Israel Medical Center, 201 Lyons Avenue, Suite G5, Newark, NJ 07112. Phone: 973-926-7746, Fax: 973-923-4635, e-mail: dgoldstein{at}sbhcs.com

Background— Ventricular assist device (VAD) support with pulsatile first generation pumps is a well-established therapy for bridging to transplantation. Shortcomings of this technology include limited applicability to small patients, noise, and high incidence of infection and pump malfunction. A second generation of pumps, spearheaded by the axial flow MicroMed DeBakey VAD®, is in clinical trials and potentially will address these shortcomings.

Methods and Results— Between November 13, 1998 and May 7, 2002, 150 patients worldwide underwent placement of the Micromed DeBakey VAD® as a bridge to transplantation. Prospectively acquired data including demographics, adverse events and outcomes was collected. Follow up is 100% with 30.4 patient-years of cumulative support time. Mean age was 48±4 years and 18% were female. Twenty-three percent had prior sternotomy. Preoperatively, 25% were on balloon pump support, 20% had renal insufficiency, and 40% were on at least two inotropes with a mean cardiac index of 1.8 L/min/m2. Mean support time was 75±81 days. Linearized rates (events/patient-year) were: reoperation for bleeding 2.03, hemolysis 0.61, device infection 0.16, thromboembolic event 0.61, pump thrombus 0.61, and pump failure 0.13. Eight-two patients (55%) were either bridged to transplantation, recovery or are ongoing and 68 (45%) have died. Several patients have been supported as outpatients.

Conclusions— This initial experience suggests that bridging to transplantation can be successfully approached with a small and quiet axial flow pump that provides low incidence of device infection and pump failure. The incidence of pump thrombus and thromboembolism is being addressed by incorporation of heparin coating to all device surfaces.


Key Words: bridge to transplantation • mechanical support • axial flow pumps • pulsatile versus continuous flow