Donate Help Contact The AHA Sign In Home
American Heart Association
Circulation
Search: search_blue_button Advanced Search
Circulation. 2003;108:II-191-II-194
doi: 10.1161/01.cir.0000089043.82199.2f
This Article
Right arrow Full Text
Right arrow Full Text (PDF)
Right arrow Alert me when this article is cited
Right arrow Alert me if a correction is posted
Right arrow Citation Map
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Download to citation manager
Right arrowRequest Permissions
Citing Articles
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Argenziano, M.
Right arrow Articles by Smith, C. R.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Argenziano, M.
Right arrow Articles by Smith, C. R.
Right arrowPubmed/NCBI databases
Medline Plus Health Information
*Endoscopy

(Circulation. 2003;108:II-191.)
© 2003 American Heart Association, Inc.


Surgery for Congenital Heart Disease

Totally Endoscopic Atrial Septal Defect Repair With Robotic Assistance

Michael Argenziano, MD; Mehmet C. Oz, MD; Takushi Kohmoto, MD; Jeffrey Morgan, MD; Jaina Dimitui, RN; Linda Mongero, CCP; James Beck, CCP; Craig R. Smith, MD

From the Division of Cardiothoracic Surgery, Columbia University College of Physicians and Surgeons, New York, NY, USA.

Correspondence to Michael Argenziano, MD, 177 Fort Washington Avenue, Milstein Hospital, Room 7–435, New York, NY. Phone: (212) 305-5888, Fax: (212) 305-2439, Email: ma66{at}columbia.edu

Background— Computer (robotic) enhancement had emerged as a facilitator of minimally invasive cardiac surgery, and has been used to perform portions of intracardiac procedures via thoracotomy incisions. This report describes the next step in this progression—the first U.S. application of robotic technology for totally endoscopic open heart surgery.

Methods and Results— Seventeen patients underwent repair of a secundum-type atrial septal defect (n=12) or patent foramen ovale (n=5) by a totally endoscopic approach, utilizing the Da Vinci robotic system. Cardiopulmonary bypass (CPB) was achieved peripherally. Cardioplegia was administered via the distal port of the arterial cannula after endo-balloon inflation. Via three port incisions in the right chest, pericardiotomy, bicaval occlusion, atriotomy, atrial septopexy, and atrial closure were performed by a surgeon seated at a computer console. A fourth 15-mm port was utilized for suction and suture passage by a patient-side assistant. The mean age of the patients was 47 years (range, 22 to 68). Aortic crossclamp time was 32 minutes (median), and CPB time was 122 minutes. In 16 patients, transesophageal echocardiography after 30 days confirmed successful repair. In one patient, a recurrent shunt was identified and repaired on postoperative day 5. Median length of stay (LOS) in the intensive care unit was 20 hours, and median hospital length of stay was 4 days.

Conclusions— Robotic technology can be utilized to perform open heart procedures safely and effectively via totally endoscopic approaches. This technique represents an option for patients seeking a reliable ASD repair but wishing to avoid sternotomy or thoracotomy.


Key Words: minimally invasive cardiac surgery • robotics • ASD repair