Background Percutaneous coronary interventions (PCIs) in saphenous vein grafts (SVGs) with thrombus have a high frequency of distal embolization. Acolysis (therapeutic ultrasound) can break up thrombus in vitro in animal models and humans. Whether this is beneficial during percutaneous SVG interventions is unknown.
Methods and Results We performed a trial of coronary ultrasound thrombolysis in which patients with an acute coronary syndrome undergoing PCI in SVGs were randomly assigned to receive acolysis or abciximab. The primary end point was a successful procedure, defined as final luminal diameter stenosis 30% or less with Thrombolysis In Myocardial Infarction grade 3 flow and freedom from major adverse cardiac events (composite of death, Q-wave, and nonQ-wave myocardial infarction [MI], emergency bypass procedure, disabling stroke, and target lesion revascularization). Of 181 enrolled, 92 received acolysis and 89 abciximab. Angiographic procedural success was achieved in 63% of acolysis patients and 82% of abciximab patients (P=0.008). Incidence of major adverse cardiac events at 30 days was 25% with acolysis and 12% with abciximab (P=0.036), attributable mainly to a greater frequency of nonQ-wave MI with acolysis (19.6% versus 7.9%, P=0.03). The incidence of Q-wave MI was also higher with acolysis (5.4% versus 2.2%, P=nonsignificant). The primary end point was achieved in 53.8% of acolysis patients and 73.1% of abciximab patients (P=0.014).
Conclusions Use of therapeutic ultrasound in vein graft lesions in patients with acute coronary syndrome had poor angiographic outcome and increased the incidence of acute ischemic complications.
Key Words: angioplasty thrombolysis ultrasonics
Related Article:
Circulation 2003 107: 2284-2286.
This article has been cited by other articles:
![]() |
B. C. Carey and J. C. Blankenship A Sequential Approach to the Management of a Massive Intracoronary Thrombus in ST Elevation Myocardial Infarction: A Case Report Angiology, February 1, 2007; 58(1): 106 - 111. [Abstract] [PDF] |
||||
![]() |
R. J. Siegel, V. N. Suchkova, T. Miyamoto, H. Luo, R. B. Baggs, Y. Neuman, M. Horzewski, V. Suorsa, S. Kobal, T. Thompson, et al. Ultrasound energy improves myocardial perfusion in the presence of coronary occlusion J. Am. Coll. Cardiol., October 6, 2004; 44(7): 1454 - 1458. [Abstract] [Full Text] [PDF] |
||||
![]() |
W. W. O'Neill and S. R. Dixon The year in interventional cardiology J. Am. Coll. Cardiol., March 3, 2004; 43(5): 875 - 890. [Full Text] [PDF] |
||||
![]() |
T. O. Cheng ATLAS: Another Negative Trial With a Positive-Sounding Acronym Circulation, September 30, 2003; 108 (13): e98 - e98. [Full Text] [PDF] |
||||
![]() |
P.J. de Feyter Percutaneous Treatment of Saphenous Vein Bypass Graft Obstructions: A Continuing Obstinate Problem Circulation, May 13, 2003; 107(18): 2284 - 2286. [Full Text] [PDF] |
||||
|
Circulation Home | Subscriptions | Archives | Feedback | Authors | Help | AHA Journals Home | Search Copyright © 2003 American Heart Association, Inc. All rights reserved. Unauthorized use prohibited. |