(Circulation. 2002;105:1708.)
© 2002 American Heart Association, Inc.
Basic Science Reports |
From the Institute of Clinical Medicine, University of Tsukuba, Tsukuba-shi, Ibaraki (T.T., J.W., Q.Y., T.Z., T.-T.-L., Y.I.); the Department of Applied Physics, School of Engineering, University of Tokyo, Bunkyo-ku, Tokyo (A.M.); and the Advanced Research Laboratory, Hitachi, Ltd, Hatoyama, Saitama (A.Y.), Japan.
Correspondence to Tohoru Takeda MD, PhD, Institute of Clinical Medicine, University of Tsukuba, Tsukuba-shi, Ibaraki 305-8575, Japan. E-mail ttakeda{at}md.tsukuba.ac.jp
Background Phase-contrast x-ray imaging using an x-ray interferometer has great potential to reveal the structures inside soft tissues, because the sensitivity of this method to hydrogen, carbon, nitrogen, and oxygen is
1000 times higher than that of the absorption-contrast x-ray method. Imaging of vessels is very important to understand the vascular distribution of organs and tumors, so the possibility of selective angiography based on phase contrast is examined with a physiological material composed of low-atomic-number elements.
Methods and Results Phase-contrast x-ray imaging was performed with a synchrotron x-ray source. Differences in refractive index, d
, of physiological saline, lactated Ringers solution, 5% glucose, artificial blood such as pyridoxylated hemoglobinpolyoxyethylene conjugate, and perfluorotributylamine were measured. Because the d
of physiological saline has highest contrast, it was used for the phase-contrast x-ray imaging of vessel, and this was compared with absorption-contrast x-ray images. Vessels >0.03 mm in diameter of excised liver from rats and a rabbit were revealed clearly in phase-contrast x-ray imaging, whereas the vessel could not be revealed at all by the absorption-contrast x-ray image. Absorption-contrast x-ray images with iodine microspheres depicted only portal veins >0.1 mm in diameter with nearly the same x-ray dose as the present phase-contrast x-ray imaging.
Conclusions Phase-contrast x-ray imaging explored clear depiction of the vessels using physiological saline with small doses of x-rays.
Key Words: imaging vessels liver angiography contrast media
This article has been cited by other articles:
![]() |
M. Shinohara, T. Yamashita, H. Tawa, M. Takeda, N. Sasaki, T. Takaya, R. Toh, A. Takeuchi, T. Ohigashi, K. Shinohara, et al. Atherosclerotic plaque imaging using phase-contrast X-ray computed tomography Am J Physiol Heart Circ Physiol, February 1, 2008; 294(2): H1094 - H1100. [Abstract] [Full Text] [PDF] |
||||
|
Circulation Home | Subscriptions | Archives | Feedback | Authors | Help | AHA Journals Home | Search Copyright © 2002 American Heart Association, Inc. All rights reserved. Unauthorized use prohibited. |