(Circulation. 2001;104:934.)
© 2001 American Heart Association, Inc.
Basic Science Reports |
From the Department of Biological Sciences and Pittsburgh NMR Center for Biomedical Research, Carnegie Mellon University (S.K., Y.J.L.W., S.J.D., M.W., C.H.), and the Department of Surgery, University of Pittsburgh (P.C.L., B.P.G.), Pittsburgh, Pa.
Correspondence to Chien Ho, PhD, Department of Biological Sciences, Carnegie Mellon University, 4400 Fifth Ave, Pittsburgh PA 15213-2683. E-mail chienho{at}andrew.cmu.edu
Background Acute cardiac allograft rejection continues to be the cause of graft loss and contributes to the morbidity and mortality after cardiac transplantation. In this study, we report a new method for detecting organ rejection in transplantation with an MR-based technique using dextran-coated ultrasmall superparamagnetic iron oxide (USPIO) particles. These particles (
27 nm in diameter) are known to shorten relaxation times in MRI experiments.
Methods and Results A new rat model of heterotopic heart and lung transplantation has been developed for MRI experiments. Allotransplantations (DA
BN) were performed (n=8), with syngeneic transplantations (BN
BN) serving as controls (n=8). MR images were obtained with a gradient echo method. At postoperative day 7, allotransplants developed moderate rejection as determined histopathologically. A significant reduction in MR signal intensity was observed after USPIO injection into rats with allotransplanted hearts. Syngeneic transplants showed no differences in MR signal intensity before and after USPIO injections. After injection of USPIO particles at postoperative day 6, a group of allotransplanted rats was treated with cyclosporin A (3 mg/kg). Animals treated with cyclosporin A for 7 days showed no reduction in MR signal intensity after USPIO reinjection at day 14, whereas animals treated for 4 days showed a significant decrease in MR signal intensity in the transplanted hearts indicative of acute graft rejection. Pathological analysis of these animals revealed that dextran-coated USPIO particles were taken up by the infiltrating macrophages that accumulated within the rejecting cardiac graft.
Conclusions This MRI method offers promise as a noninvasive method for detecting transplant allograft rejection.
Key Words: magnetic resonance imaging rejection diagnosis transplantation
This article has been cited by other articles:
![]() |
Y. L. Wu, Q. Ye, K. Sato, L. M. Foley, T. K. Hitchens, and C. Ho Noninvasive Evaluation of Cardiac Allograft Rejection by Cellular and Functional Cardiac Magnetic Resonance J. Am. Coll. Cardiol. Img., June 1, 2009; 2(6): 731 - 741. [Abstract] [Full Text] [PDF] |
||||
![]() |
J.-L. Figueiredo, M. Nahrendorf, D. E. Sosnovik, and R. Weissleder MRI of a Novel Murine Working Heart Transplant Model Circ Heart Fail, May 1, 2009; 2(3): 272 - 274. [Full Text] [PDF] |
||||
![]() |
T. Christen, M. Nahrendorf, M. Wildgruber, F. K. Swirski, E. Aikawa, P. Waterman, K. Shimizu, R. Weissleder, and P. Libby Molecular Imaging of Innate Immune Cell Function in Transplant Rejection Circulation, April 14, 2009; 119(14): 1925 - 1932. [Abstract] [Full Text] [PDF] |
||||
![]() |
M. Nahrendorf, D. E. Sosnovik, B. A. French, F. K. Swirski, F. Bengel, M. M. Sadeghi, J. R. Lindner, J. C. Wu, D. L. Kraitchman, Z. A. Fayad, et al. Multimodality Cardiovascular Molecular Imaging, Part II Circ Cardiovasc Imaging, January 1, 2009; 2(1): 56 - 70. [Full Text] [PDF] |
||||
![]() |
J. Terrovitis, M. Stuber, A. Youssef, S. Preece, M. Leppo, E. Kizana, M. Schar, G. Gerstenblith, R. G. Weiss, E. Marban, et al. Magnetic Resonance Imaging Overestimates Ferumoxide-Labeled Stem Cell Survival After Transplantation in the Heart Circulation, March 25, 2008; 117(12): 1555 - 1562. [Abstract] [Full Text] [PDF] |
||||
![]() |
S. Biswal, D. L. Resnick, J. M. Hoffman, and S. S. Gambhir Molecular Imaging: Integration of Molecular Imaging into the Musculoskeletal Imaging Practice Radiology, September 1, 2007; 244(3): 651 - 671. [Abstract] [Full Text] [PDF] |
||||
![]() |
F. A. Jaffer, P. Libby, and R. Weissleder Molecular Imaging of Cardiovascular Disease Circulation, August 28, 2007; 116(9): 1052 - 1061. [Full Text] [PDF] |
||||
![]() |
D. E. Sosnovik, M. Nahrendorf, and R. Weissleder Molecular Magnetic Resonance Imaging in Cardiovascular Medicine Circulation, April 17, 2007; 115(15): 2076 - 2086. [Full Text] [PDF] |
||||
![]() |
D. E. Sosnovik, M. Nahrendorf, N. Deliolanis, M. Novikov, E. Aikawa, L. Josephson, A. Rosenzweig, R. Weissleder, and V. Ntziachristos Fluorescence Tomography and Magnetic Resonance Imaging of Myocardial Macrophage Infiltration in Infarcted Myocardium In Vivo Circulation, March 20, 2007; 115(11): 1384 - 1391. [Abstract] [Full Text] [PDF] |
||||
![]() |
H. N. Skouri, G. W. Dec, M. G. Friedrich, and L. T. Cooper Noninvasive Imaging in Myocarditis J. Am. Coll. Cardiol., November 21, 2006; 48(10): 2085 - 2093. [Abstract] [Full Text] [PDF] |
||||
![]() |
G. Stoll and M. Bendszus Inflammation and Atherosclerosis: Novel Insights Into Plaque Formation and Destabilization Stroke, July 1, 2006; 37(7): 1923 - 1932. [Abstract] [Full Text] [PDF] |
||||
![]() |
Y. L. Wu, Q. Ye, L. M. Foley, T. K. Hitchens, K. Sato, J. B. Williams, and C. Ho In situ labeling of immune cells with iron oxide particles: An approach to detect organ rejection by cellular MRI PNAS, February 7, 2006; 103(6): 1852 - 1857. [Abstract] [Full Text] [PDF] |
||||
![]() |
A. M. Lutz, D. Weishaupt, E. Persohn, K. Goepfert, J. Froehlich, B. Sasse, J. Gottschalk, B. Marincek, and A. H. Kaim Imaging of Macrophages in Soft-Tissue Infection in Rats: Relationship between Ultrasmall Superparamagnetic Iron Oxide Dose and MR Signal Characteristics Radiology, March 1, 2005; 234(3): 765 - 775. [Abstract] [Full Text] [PDF] |
||||
![]() |
A. M. Lutz, C. Seemayer, C. Corot, R. E. Gay, K. Goepfert, B. A. Michel, B. Marincek, S. Gay, and D. Weishaupt Detection of Synovial Macrophages in an Experimental Rabbit Model of Antigen-induced Arthritis: Ultrasmall Superparamagnetic Iron Oxide-enhanced MR Imaging Radiology, October 1, 2004; 233(1): 149 - 157. [Abstract] [Full Text] [PDF] |
||||
![]() |
E. M. Shapiro, S. Skrtic, K. Sharer, J. M. Hill, C. E. Dunbar, and A. P. Koretsky MRI detection of single particles for cellular imaging PNAS, July 27, 2004; 101(30): 10901 - 10906. [Abstract] [Full Text] [PDF] |
||||
![]() |
F. A. Jaffer and R. Weissleder Seeing Within: Molecular Imaging of the Cardiovascular System Circ. Res., March 5, 2004; 94(4): 433 - 445. [Abstract] [Full Text] [PDF] |
||||
![]() |
I. Kondo, K. Ohmori, A. Oshita, H. Takeuchi, J. Yoshida, K. Shinomiya, S. Fuke, T. Suzuki, K. Mizushige, and M. Kohno Leukocyte-Targeted Myocardial Contrast Echocardiography Can Assess the Degree of Acute Allograft Rejection in a Rat Cardiac Transplantation Model Circulation, March 2, 2004; 109(8): 1056 - 1061. [Abstract] [Full Text] [PDF] |
||||
|
Circulation Home | Subscriptions | Archives | Feedback | Authors | Help | AHA Journals Home | Search Copyright © 2001 American Heart Association, Inc. All rights reserved. Unauthorized use prohibited. |