Donate Help Contact The AHA Sign In Home
American Heart Association
Circulation
Search: search_blue_button Advanced Search
Circulation. 2001;104:1946-1951
doi: 10.1161/hc4101.097117
This Article
Right arrow Full Text
Right arrow Full Text (PDF)
Right arrow Alert me when this article is cited
Right arrow Alert me if a correction is posted
Right arrow Citation Map
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Download to citation manager
Right arrowRequest Permissions
Citing Articles
Right arrow Citing Articles via HighWire
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Ciaccio, E. J.
Right arrow Articles by Wit, A. L.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Ciaccio, E. J.
Right arrow Articles by Wit, A. L.
Related Collections
Right arrow Arrythmias-basic studies
Right arrow Quantitative modeling
Right arrow Ablation/ICD/surgery

(Circulation. 2001;104:1946.)
© 2001 American Heart Association, Inc.


Basic Science Reports

Static Relationship of Cycle Length to Reentrant Circuit Geometry

Edward J. Ciaccio, PhD; Constantino Costeas, MD; James Coromilas, MD; Andrew L. Wit, PhD

From the Departments of Pharmacology (E.J.C., C.C., J.C., A.L.W.) and Biomedical Engineering (E.J.C.) and the Center for Molecular Therapeutics (A.L.W.), College of Physicians and Surgeons, Columbia University, New York, NY.

Correspondence to Edward J. Ciaccio, PhD, Department of Pharmacology, PH7W, Columbia University, 630 W 168th St, New York, NY 10032. E-mail ciaccio{at}columbia.edu

Background— Knowledge of the pathway common to both wave fronts in figure-8 reentrant circuits (ie, the isthmus) is of importance for catheter ablation to stop reentrant ventricular tachycardia. It was hypothesized that quantitative measures of reentry isthmus geometry were interrelated and could be correlated with tachycardia cycle length.

Methods and Results— A canine infarct model of reentrant ventricular tachycardia in the epicardial border zone with a figure-8 pattern of conduction was used for initial analysis (experiments in 20 canine hearts with monomorphic reentry). Sinus-rhythm and reentry activation maps were constructed, and quantitative (skeletonized) geometric parameters of the isthmus and border zone were measured from the maps. Regression equations were used to determine significant correlation relationships between skeletonized variables, which can be described as follows. Tachycardia cycle length, measured from the ECG R-R interval, increases with increasing isthmus length, width, narrowest width, angle with respect to muscle fibers, and circuit path length determined by use of sinus-rhythm measurements. After this procedure, in 5 test-set experiments, tachycardia cycle length measured from the R-R interval, in combination with regression coefficients calculated from initial experiments, correctly predicted isthmus geometry (mean estimated/actual isthmus overlap 70.5%). Also, the circuit path length determined with sinus-rhythm measurements correctly estimated the tachycardia cycle length (mean error 6.2±2.5 ms).

Conclusions— Correlation relationships derived from measurements using reentry and sinus-rhythm activation maps are useful to assess isthmus geometry on the basis of tachycardia cycle length. Such estimates may improve catheter ablation site targeting during clinical electrophysiological study.


Key Words: catheters • ablation • reentry • tachycardia • ventricles




This article has been cited by other articles:


Home page
Am. J. Physiol. Heart Circ. Physiol.Home page
E. J. Ciaccio
Premature excitation and onset of reentrant ventricular tachycardia
Am J Physiol Heart Circ Physiol, October 1, 2002; 283(4): H1703 - H1712.