Donate Help Contact The AHA Sign In Home
American Heart Association
Circulation
Search: search_blue_button Advanced Search
Circulation. 2001;104:1313-1319
doi: 10.1161/hc3601.094295
This Article
Right arrow Full Text
Right arrow Full Text (PDF)
Right arrow Alert me when this article is cited
Right arrow Alert me if a correction is posted
Right arrow Citation Map
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Download to citation manager
Right arrowRequest Permissions
Citing Articles
Right arrow Citing Articles via HighWire
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Chattipakorn, N.
Right arrow Articles by Ideker, R. E.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Chattipakorn, N.
Right arrow Articles by Ideker, R. E.
Related Collections
Right arrow Arrythmias-basic studies
Right arrow Arrhythmias, clinical electrophysiology, drugs

(Circulation. 2001;104:1313.)
© 2001 American Heart Association, Inc.


Basic Science Reports

Mechanism of Ventricular Defibrillation for Near-Defibrillation Threshold Shocks

A Whole-Heart Optical Mapping Study in Swine

Nipon Chattipakorn, MD, PhD; Isabelle Banville, MS; Richard A. Gray, PhD; Raymond E. Ideker, MD, PhD

From the Departments of Medicine (N.C., R.E.I.), Biomedical Engineering (I.B., R.A.G., R.E.I.), and Physiology (R.E.I.), University of Alabama at Birmingham.

Correspondence to Nipon Chattipakorn, MD, PhD, 1670 University Blvd, B-140, Birmingham, AL 35294-0019. E-mail toon{at}crml.uab.edu

Background— To study the mechanism by which shocks succeed (SDF) or fail (FDF) to defibrillate, global cardiac activation and recovery and their relationship to defibrillation outcome were investigated for shock strengths with approximately equal SDF and FDF outcomes (DFT50).

Methods and Results— In 6 isolated pig hearts, dual-camera video imaging was used to record optically from {approx}8000 sites on the anterior and posterior ventricular surfaces before and after 10 DFT50 biphasic shocks. The interval between the shock and the last ventricular fibrillation activation preceding the shock (coupling interval, CI) and the time from shock onset to 90% repolarization of the immediate postshock action potential (RT90) were determined at all sites. Of 60 shocks, 31 were SDF. The CI (59±7 versus 52±6 ms) and RT90 (108±19 versus 88±8 ms) were significantly longer for SDF than FDF episodes. Spatial dispersions of CI (36±5 versus 34±3 ms) and RT90 (40±16 versus 40±8 ms) were not significantly different for SDF versus FDF episodes. The first global activation cycle appeared focally on the left ventricular apical epicardium 78±32 ms after the shock.

Conclusions— For near-threshold shocks, defibrillation outcome correlates with the electrical state of the heart at the time of the shock and on RT. Global dispersion of RT was similar in both SDF and FDF episodes, suggesting that it is not crucial in determining defibrillation outcome after DFT50 shocks.


Key Words: mapping • defibrillation




This article has been cited by other articles:


Home page
J Am Coll CardiolHome page
J. P. Daubert and S.-S. Sheu
Mystery of Biphasic Defibrillation Waveform Efficacy: Is it Calcium?
J. Am. Coll. Cardiol., September 2, 2008; 52(10): 836 - 838.
[Full Text] [PDF]


Home page
CirculationHome page
J. D. Day, R. N. Doshi, P. Belott, U. Birgersdotter-Green, M. Behboodikhah, P. Ott, K. A. Glatter, S. Tobias, H. Frumin, B. K. Lee, et al.
Inductionless or Limited Shock Testing Is Possible in Most Patients With Implantable Cardioverter- Defibrillators/Cardiac Resynchronization Therapy Defibrillators: Results of the Multicenter ASSURE Study (Arrhythmia Single Shock Defibrillation Threshold Testing Versus Upper Limit of Vulnerability: Risk Reduction Evaluation With Implantable Cardioverter-Defibrillator Implantations)
Circulation, May 8, 2007; 115(18): 2382 - 2389.
[Abstract] [Full Text] [PDF]


Home page
Am. J. Physiol. Heart Circ. Physiol.Home page
S. F. Mironov, F. J. Vetter, and A. M. Pertsov
Fluorescence imaging of cardiac propagation: spectral properties and filtering of optical action potentials
Am J Physiol Heart Circ Physiol, July 1, 2006; 291(1): H327 - H335.
[Abstract] [Full Text] [PDF]


Home page
Phil Trans R Soc AHome page
D. W Bourn, M. M Maleckar, B. Rodriguez, and N. A Trayanova
Mechanistic enquiry into the effect of increased pacing rate on the upper limit of vulnerability
Phil Trans R Soc A, June 15, 2006; 364(1843): 1333 - 1348.
[Abstract] [Full Text] [PDF]


Home page
Cardiovasc ResHome page
C. W. Zemlin, S. Mironov, and A. M. Pertsov
Near-threshold field stimulation: Intramural versus surface activation
Cardiovasc Res, January 1, 2006; 69(1): 98 - 106.
[Abstract] [Full Text] [PDF]


Home page
Proc. Natl. Acad. Sci. USAHome page
R. A. Gray and N. Chattipakorn
Termination of spiral waves during cardiac fibrillation via shock-induced phase resetting
PNAS, March 29, 2005; 102(13): 4672 - 4677.
[Abstract] [Full Text] [PDF]


Home page
Am. J. Physiol. Heart Circ. Physiol.Home page
D. C.-S. Tai, B. J. Caldwell, I. J. LeGrice, D. A. Hooks, A. J. Pullan, and B. H. Smaill
Correction of motion artifact in transmembrane voltage-sensitive fluorescent dye emission in hearts
Am J Physiol Heart Circ Physiol, September 1, 2004; 287(3): H985 - H993.
[Abstract] [Full Text] [PDF]


Home page
Am. J. Physiol. Heart Circ. Physiol.Home page
M. G. Hillebrenner, J. C. Eason, and N. A. Trayanova
Mechanistic inquiry into decrease in probability of defibrillation success with increase in complexity of preshock reentrant activity
Am J Physiol Heart Circ Physiol, March 1, 2004; 286(3): H909 - H917.
[Abstract] [Full Text] [PDF]


Home page
Cardiovasc ResHome page
J. R de Groot
Why shocking might be not shocking enough
Cardiovasc Res, January 1, 2004; 61(1): 9 - 10.
[Full Text] [PDF]


Home page
Cardiovasc ResHome page
N. Chattipakorn, I. Banville, R. A Gray, and R. E Ideker
Effects of shock strengths on ventricular defibrillation failure
Cardiovasc Res, January 1, 2004; 61(1): 39 - 44.
[Abstract] [Full Text] [PDF]


Home page
Am. J. Physiol. Heart Circ. Physiol.Home page
H. Qin, M. W. Kay, N. Chattipakorn, D. T. Redden, R. E. Ideker, and J. M. Rogers
Effects of heart isolation, voltage-sensitive dye, and electromechanical uncoupling agents on ventricular fibrillation
Am J Physiol Heart Circ Physiol, May 1, 2003; 284(5): H1818 - H1826.
[Abstract] [Full Text] [PDF]


Home page
Am. J. Physiol. Heart Circ. Physiol.Home page
M. Yashima, Y.-H. Kim, S. Armin, T.-J. Wu, Y. Miyauchi, W. J. Mandel, P.-S. Chen, and H. S. Karagueuzian
On the mechanism of the probabilistic nature of ventricular defibrillation threshold
Am J Physiol Heart Circ Physiol, January 1, 2003; 284(1): H249 - H255.
[Abstract] [Full Text] [PDF]