Donate Help Contact The AHA Sign In Home
American Heart Association
Circulation
Search: search_blue_button Advanced Search
Circulation. 2001;104:58-62
doi: 10.1161/hc2601.091710
This Article
Right arrow Full Text
Right arrow Full Text (PDF)
Right arrow Alert me when this article is cited
Right arrow Alert me if a correction is posted
Right arrow Citation Map
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Download to citation manager
Right arrowRequest Permissions
Citing Articles
Right arrow Citing Articles via HighWire
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Perisinakis, K.
Right arrow Articles by Gourtsoyiannis, N.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Perisinakis, K.
Right arrow Articles by Gourtsoyiannis, N.
Related Collections
Right arrow Electrophysiology
Right arrow Ablation/ICD/surgery

(Circulation. 2001;104:58.)
© 2001 American Heart Association, Inc.


Clinical Investigation and Reports

Accurate Assessment of Patient Effective Radiation Dose and Associated Detriment Risk From Radiofrequency Catheter Ablation Procedures

Kostas Perisinakis, PhD; John Damilakis, PhD; Nicholas Theocharopoulos, MSc; Emmanouel Manios, MD, PhD; Panayiotis Vardas, MD, PhD; Nicholas Gourtsoyiannis, MD, PhD

From the University of Crete, Faculty of Medicine, Iraklion, Crete, Greece.

Background—Radiofrequency (RF) cardiac catheter ablation procedures may require extended fluoroscopic exposure resulting in elevated radiation risk. The aim of the present study was to accurately establish RF ablation radiation risk levels and to provide means for accurate patient risk estimation from studies performed in any electrophysiology laboratory.

Methods and Results—Fluoroscopy required during cardiac ablation was classified into 4 types identified by beam orientation and irradiated tissue: (1) posteroanterior exposure during catheter advancing from the groin to the heart, (2) posteroanterior heart exposure, (3) left anterior oblique heart exposure, and (4) right anterior oblique heart exposure. The duration of each exposure was monitored in 24 patients undergoing RF cardiac ablation. Dose per minute of fluoroscopy was measured at 15 organs/tissues for each projection with the use of anthropomorphic phantom and thermoluminescence dosimetry. The effective dose rate was 219, 144, 136, and 112 µGy/min for groin-to-heart posteroanterior, posteroanterior, left anterior oblique, and right anterior oblique exposure, respectively. A typical ablation procedure results in a total effective dose of 8.3 mSv per hour of fluoroscopy. The average excess of fatal cancers was estimated to be 650 and 480 per million patients undergoing RF ablation requiring 1 hour of fluoroscopy for US and UK populations, respectively. The average risk for genetic defects was determined to be 1 per million births.

Conclusions—Radiation risk from RF cardiac ablation is moderate compared with other complications, but it may highly exceed radiation risk from common radiological procedures. Efforts should be made toward minimization of patient radiation risk from RF ablation procedures.


Key Words: catheter ablation • radiography • electrophysiology • risk factors




This article has been cited by other articles:


Home page
NEJMHome page
R. Fazel, H. M. Krumholz, Y. Wang, J. S. Ross, J. Chen, H. H. Ting, N. D. Shah, K. Nasir, A. J. Einstein, and B. K. Nallamothu
Exposure to Low-Dose Ionizing Radiation from Medical Imaging Procedures
N. Engl. J. Med., August 27, 2009; 361(9): 849 - 857.
[Abstract] [Full Text] [PDF]


Home page
EuropaceHome page
H. Calkins, J. Brugada, D. L. Packer, R. Cappato, S.-A. Chen, H. J.G. Crijns, R. J. Damiano Jr, D. W. Davies, D. E. Haines, M. Haissaguerre, et al.
HRS/EHRA/ECAS Expert Consensus Statement on Catheter and Surgical Ablation of Atrial Fibrillation: Recommendations for Personnel, Policy, Procedures and Follow-Up: A report of the Heart Rhythm Society (HRS) Task Force on Catheter and Surgical Ablation of Atrial Fibrillation Developed in partnership with the European Heart Rhythm Association (EHRA) and the European Cardiac Arrhythmia Society (ECAS); in collaboration with the American College of Cardiology (ACC), American Heart Association (AHA), and the Society of Thoracic Surgeons (STS). Endorsed and Approved by the governing bodies of the American College of Cardiology, the American Heart Association, the European Cardiac Arrhythmia Society, the European Heart Rhythm Association, the Society of Thoracic Surgeons, and the Heart Rhythm Society.
Europace, June 1, 2007; 9(6): 335 - 379.
[Full Text] [PDF]


Home page
Br. J. Radiol.Home page
N Theocharopoulos, J Damilakis, K Perisinakis, E Manios, P Vardas, and N Gourtsoyiannis
Occupational exposure in the electrophysiology laboratory: quantifying and minimizing radiation burden
Br. J. Radiol., August 1, 2006; 79(944): 644 - 651.
[Abstract] [Full Text] [PDF]


Home page
EuropaceHome page
E. P. Efstathopoulos, D. G. Katritsis, S. Kottou, N. Kalivas, E. Tzanalaridou, E. Giazitzoglou, S. Korovesis, and K. Faulkner
Patient and staff radiation dosimetry during cardiac electrophysiology studies and catheter ablation procedures: a comprehensive analysis
Europace, June 1, 2006; 8(6): 443 - 448.
[Abstract] [Full Text] [PDF]


Home page
Eur Heart JHome page
M. J. Earley, R. Showkathali, M. Alzetani, P. M. Kistler, D. Gupta, D. J. Abrams, J. A. Horrocks, S. J. Harris, S. C. Sporton, and R. J. Schilling
Radiofrequency ablation of arrhythmias guided by non-fluoroscopic catheter location: a prospective randomized trial
Eur. Heart J., May 2, 2006; 27(10): 1223 - 1229.
[Abstract] [Full Text] [PDF]


Home page
Radiat Prot DosimetryHome page
R. Padovani and E. Quai
Patient dosimetry approaches in interventional cardiology and literature dose data review
Radiat Prot Dosimetry, December 1, 2005; 117(1-3): 217 - 221.
[Abstract] [Full Text] [PDF]


Home page
Radiat Prot DosimetryHome page
A. Trianni, G. Chizzola, H. Toh, E. Quai, E. Cragnolini, G. Bernardi, A. Proclemer, and R. Padovani
Patient skin dosimetry in haemodynamic and electrophysiology interventional cardiology
Radiat Prot Dosimetry, December 1, 2005; 117(1-3): 241 - 246.
[Abstract] [Full Text] [PDF]


Home page
CirculationHome page
L. Lickfett, M. Mahesh, C. Vasamreddy, D. Bradley, V. Jayam, Z. Eldadah, T. Dickfeld, D. Kearney, D. Dalal, B. Luderitz, et al.
Radiation Exposure During Catheter Ablation of Atrial Fibrillation
Circulation, November 9, 2004; 110(19): 3003 - 3010.
[Abstract] [Full Text] [PDF]


Home page
RadiologyHome page
K. Perisinakis, J. Damilakis, N. Theocharopoulos, G. Papadokostakis, A. Hadjipavlou, and N. Gourtsoyiannis
Patient Exposure and Associated Radiation Risks from Fluoroscopically Guided Vertebroplasty or Kyphoplasty
Radiology, September 1, 2004; 232(3): 701 - 707.
[Abstract] [Full Text] [PDF]


Home page
CirculationHome page
S. Schalla, M. Saeed, C. B. Higgins, A. Martin, O. Weber, and P. Moore
Magnetic Resonance-Guided Cardiac Catheterization in a Swine Model of Atrial Septal Defect
Circulation, October 14, 2003; 108(15): 1865 - 1870.
[Abstract] [Full Text] [PDF]


Home page
HeartHome page
R. J Schilling
Which patient should be referred to an electrophysiologist: supraventricular tachycardia
Heart, March 1, 2002; 87(3): 299 - 304.
[Full Text] [PDF]