(Circulation. 2000;102:1053.)
© 2000 American Heart Association, Inc.
Basic Science Reports |
From the Cardiac Ultrasound Laboratory (T.B., R.A.M., M.D.H., R.A.L.), Cardiovascular Surgical Unit (J.L.G.), and Cardiac MRI Unit (G.H.), Massachusetts General Hospital, Harvard Medical School, Boston.
Correspondence to Robert A. Levine, MD, Cardiac Ultrasound Laboratory, Massachusetts General Hospital, VBK 508, Boston, MA 02114. E-mail rlevine{at}partners.org
BackgroundNoninvasive quantification of regurgitation is limited because Doppler measures velocity, not flow. Because backscattered Doppler power is proportional to sonified blood volume, power times velocity should be proportional to flow rate. Early studies, however, suggested that this held only for laminar flow, not for regurgitant jets, in which turbulence and fluid entrainment augment scatter. We therefore hypothesized that this Doppler power principle can be applied at the proximal vena contracta, where flow is laminar before entrainment, so that the power-times-velocity integral should vary linearly with flow rate and its time integral with stroke volume (SV).
Methods and ResultsThis was tested in vitro with steady and pulsatile flow through 0.07- to 0.8-cm2 orifices and in 36 hemodynamic stages in vivo, replacing the left atrium with a rigid chamber and column for direct visual recording of mitral regurgitant SV (MRSV). In 12 patients, MRSV was compared with MRI mitral inflow minus aortic outflow and in 11 patients with 3D echo left ventricular ejection volumeDoppler aortic forward SV. Vena contracta power in the narrow high-velocity spectrum from a broad measuring beam was calibrated against that from a narrow reference beam of known area. Calculated and actual flow rates and SV correlated well in vitro (r=0.99, 0.99; error=-1.6±2.5 mL/s, -2.4±2.9 mL), in vivo (MRSV: r=0.98, error=0.04±0.87 mL), and in patients (MRSV: r=0.98, error=-2.8±4.5 mL).
ConclusionsThe power-velocity integral at the vena contracta provides an accurate direct measurement of regurgitant flow, overcoming the limitations of existing Doppler techniques.
Key Words: echocardiography regurgitation mitral valve blood flow
This article has been cited by other articles:
![]() |
T. Buck, B. Plicht, P. Hunold, R. A. Mucci, R. Erbel, and R. A. Levine Broad-beam spectral Doppler sonification of the vena contracta using matrix-array technology: A new solution for semi-automated quantification of mitral regurgitant flow volume and orifice area J. Am. Coll. Cardiol., March 1, 2005; 45(5): 770 - 779. [Abstract] [Full Text] [PDF] |
||||
![]() |
W. A. Zoghbi, M. Enriquez-Sarano, E. Foster, P. A. Grayburn, C. D. Kraft, R. A. Levine, P. Nihoyannopoulos, C. M. Otto, M. A. Quinones, H. Rakowski, et al. American Society of Echocardiography: recommendations for evaluation of the severity of native valvular regurgitation with two-dimensional and Doppler echocardiography : A report from the American Society of Echocardiography's Nomenclature and Standards Committee and The Task Force on Valvular Regurgitation, developed in conjunction with the American College of Cardiology Echocardiography Committee, The Cardiac Imaging Committee, Council on Clinical Cardiology, The American Heart Association, and the European Society of Cardiology Working Group on Echocardiography, represented by: Eur J Echocardiogr, December 1, 2003; 4(4): 237 - 261. [Full Text] [PDF] |
||||
![]() |
M. Sitges, M. Jones, T. Shiota, D. L. Prior, J. X. Qin, H. Tsujino, F. Bauer, Y. J. Kim, D. Deserranno, N. L. Greenberg, et al. Interaliasing distance of the flow convergence surface for determining mitral regurgitant volume: a validation study in a chronic animal model J. Am. Coll. Cardiol., October 1, 2001; 38(4): 1195 - 1202. [Abstract] [Full Text] [PDF] |
||||
![]() |
C. DAVIES and D. SAHN Detection and significance of subclinical mitral regurgitation by colour Doppler techniques Heart, April 1, 2001; 85(4): 369 - 370. [Full Text] |
||||
|