(Circulation. 2000;102:523.)
© 2000 American Heart Association, Inc.
Clinical Investigation and Reports |
From Stanford University Medical Center, Stanford, Calif (A.O., M.H., J.A.M., S.N.O., P.G.Y., P.J.F.); University of Texas Health Science Center, San Antonio (S.R.B.); Beth Israel Hospital, Boston, Mass (D.S.B); Yale University Hospital, New Haven, Conn (M.W.C.); The New York Hospital, New York, NY (E.D.); Georgetown University Medical Center, Washington, DC (D.J.D.); Washington Hospital Center, Washington, DC (M.B.L.); Lenox Hill Hospital, New York, NY (J.W.M.); Lubbock Medical Center, Lubbock, Tex (P.A.O.); University of Florida, Gainesville (C.J.P.); William Beaumont Hospital, Royal Oak, Mich (R.D.S.); Maimonides Medical Center, Brooklyn, NY (J.S.); The Sanger Clinic, Charlotte, NC (C.A.S.); University of Texas, Houston, (R.W.S.); the Scripps Clinic, La Jolla, Calif (P.S.T.); and Duke University Medical Center, Durham, NC (J.P.Z.).
Correspondence to Peter J. Fitzgerald, MD, PhD, Center for Research in Cardiovascular Interventions, Stanford University Medical Center, 300 Pasteur Dr, Room H3554, Stanford, CA 94305-5246. E-mail peter_fitzgerald{at}cvmed.stanford.edu
BackgroundIntravascular ultrasound (IVUS) can assess stent geometry more accurately than angiography. Several studies have demonstrated that the degree of stent expansion as measured by IVUS directly correlated to clinical outcome. However, it is unclear if routine ultrasound guidance of stent implantation improves clinical outcome as compared with angiographic guidance alone.
Methods and ResultsThe CRUISE (Can Routine Ultrasound Influence Stent Expansion) study, a multicenter study IVUS substudy of the Stent Anti-thrombotic Regimen Study, was designed to assess the impact of IVUS on stent deployment in the high-pressure era. Nine centers were prospectively assigned to stent deployment with the use of ultrasound guidance and 7 centers to angiographic guidance alone with documentary (blinded) IVUS at the conclusion of the procedure. A total of 525 patients were enrolled with completed quantitative coronary angiography, quantitative coronary ultrasound, and clinical events adjudicated at 9 months for 499 patients. The IVUS-guided group had a larger minimal lumen diameter (2.9±0.4 versus 2.7±0.5 mm, P<0.001) by quantitative coronary angiography and a larger minimal stent area (7.78±1.72 versus 7.06±2.13 mm2, P<0.001) by quantitative coronary ultrasound. Target vessel revascularization, defined as clinically driven repeat interventional or surgical therapy of the index vessel at 9 month-follow-up, occurred significantly less frequently in the IVUS-guided group (8.5% versus 15.3%, P<0.05; relative reduction of 44%).
ConclusionsThese data suggest that ultrasound guidance of stent implantation may result in more effective stent expansion compared with angiographic guidance alone.
Key Words: stents coronary disease ultrasonics angiography restenosis
This article has been cited by other articles:
![]() |
S. Kaul Man Must Measure: Except for Cardiologists! J. Am. Coll. Cardiol. Img., September 1, 2009; 2(9): 1111 - 1113. [Full Text] [PDF] |
||||
![]() |
G. W. Stone and G. S. Mintz Unprotected Left Main Intervention: The Light at the End of the Tunnel? Circ Cardiovasc Interv, June 1, 2009; 2(3): 156 - 158. [Full Text] [PDF] |
||||
![]() |
S.-J. Park, Y.-H. Kim, D.-W. Park, S.-W. Lee, W.-J. Kim, J. Suh, S.-C. Yun, C. W. Lee, M.-K. Hong, J.-H. Lee, et al. Impact of Intravascular Ultrasound Guidance on Long-Term Mortality in Stenting for Unprotected Left Main Coronary Artery Stenosis Circ Cardiovasc Interv, June 1, 2009; 2(3): 167 - 177. [Abstract] [Full Text] [PDF] |
||||
![]() |
R. J. Russo, P. D. Silva, P. S. Teirstein, M. J. Attubato, C. J. Davidson, A. C. DeFranco, P. J. Fitzgerald, S. L. Goldberg, J. B. Hermiller, M. B. Leon, et al. A Randomized Controlled Trial of Angiography Versus Intravascular Ultrasound-Directed Bare-Metal Coronary Stent Placement (The AVID Trial) Circ Cardiovasc Interv, April 1, 2009; 2(2): 113 - 123. [Abstract] [Full Text] [PDF] |
||||
![]() |
R. V. Kelly, M. J. Gillespie, M. G. Cohen, D. P. McLaughlin, E. Magnus Ohman, and G. A. Stouffer The Contrast Media Iohexol Causes Vasoconstriction of the Proximal Left Anterior Descending Coronary Artery: Implications for Appropriate Stent Sizing Angiology, October 1, 2008; 59(5): 574 - 580. [Abstract] [PDF] |
||||
![]() |
P. Roy, D. H. Steinberg, S. J. Sushinsky, T. Okabe, T. L. Pinto Slottow, K. Kaneshige, Z. Xue, L. F. Satler, K. M. Kent, W. O. Suddath, et al. The potential clinical utility of intravascular ultrasound guidance in patients undergoing percutaneous coronary intervention with drug-eluting stents Eur. Heart J., August 1, 2008; 29(15): 1851 - 1857. [Abstract] [Full Text] [PDF] |
||||
![]() |
C. Di Mario and P. Barlis Optical Coherence Tomography: A New Tool to Detect Tissue Coverage in Drug-Eluting Stents J. Am. Coll. Cardiol. Intv., April 1, 2008; 1(2): 174 - 175. [Full Text] [PDF] |
||||
![]() |
B. L. van der Hoeven, S.-S. Liem, J. Dijkstra, S. C. Bergheanu, H. Putter, M. L. Antoni, D. E. Atsma, M. Bootsma, K. Zeppenfeld, J. W. Jukema, et al. Stent Malapposition After Sirolimus-Eluting and Bare-Metal Stent Implantation in Patients with ST-Segment Elevation Myocardial Infarction: Acute and 9-Month Intravascular Ultrasound Results of the MISSION! Intervention Study J. Am. Coll. Cardiol. Intv., April 1, 2008; 1(2): 192 - 201. [Abstract] [Full Text] [PDF] |
||||
![]() |
E. Romagnoli, G. M. Sangiorgi, J. Cosgrave, E. Guillet, and A. Colombo Drug-eluting stenting the case for post-dilation. J. Am. Coll. Cardiol. Intv., February 1, 2008; 1(1): 22 - 31. [Abstract] [Full Text] [PDF] |
||||
![]() |
R. J Russo, P. D Silva, and M. Yeager Coronary artery overexpansion increases neointimal hyperplasia after stent placement in a porcine model Heart, December 1, 2007; 93(12): 1609 - 1615. [Abstract] [Full Text] [PDF] |
||||
![]() |
A K Mitra and D K Agrawal In stent restenosis: bane of the stent era. J. Clin. Pathol., March 1, 2006; 59(3): 232 - 239. [Abstract] [Full Text] [PDF] |
||||
![]() |
S. Kruger, K.-C. Koch, I. Kaumanns, M. W. Merx, P. Hanrath, and R. Hoffmann Clinical Significance of Fractional Flow Reserve for Evaluation of Functional Lesion Severity in Stent Restenosis and Native Coronary Arteries Chest, September 1, 2005; 128(3): 1645 - 1649. [Abstract] [Full Text] [PDF] |
||||
![]() |
Authors/Task Force Members, S. Silber, P. Albertsson, F. F. Aviles, P. G. Camici, A. Colombo, C. Hamm, E. Jorgensen, J. Marco, J.-E. Nordrehaug, et al. Guidelines for Percutaneous Coronary Interventions: The Task Force for Percutaneous Coronary Interventions of the European Society of Cardiology Eur. Heart J., April 2, 2005; 26(8): 804 - 847. [Full Text] [PDF] |
||||
![]() |
T. H. Lee, D. H. Kim, B.-H. Lee, H. J. Kim, C. H. Choi, K. P. Park, D. S. Jung, S. Kim, and T. Y. Moon Preliminary Results of Endovascular Stent-Assisted Angioplasty for Symptomatic Middle Cerebral Artery Stenosis AJNR Am. J. Neuroradiol., January 1, 2005; 26(1): 166 - 174. [Abstract] [Full Text] [PDF] |
||||
![]() |
M. Sahara, H. Kirigaya, Y. Oikawa, J. Yajima, K. Nagashima, H. Hara, K. Ogasawara, and T. Aizawa Soft plaque detected on intravascular ultrasound is the strongest predictor of in-stent restenosis: an intravascular ultrasound study Eur. Heart J., November 2, 2004; 25(22): 2026 - 2033. [Abstract] [Full Text] [PDF] |
||||
![]() |
J. L. Orford, A. Lerman, and D. R. Holmes Routine intravascular ultrasound guidance of percutaneous coronary intervention: A critical reappraisal J. Am. Coll. Cardiol., April 21, 2004; 43(8): 1335 - 1342. [Abstract] [Full Text] [PDF] |
||||
![]() |
M. Sahara, H. Kirigaya, Y. Oikawa, J. Yajima, K. Ogasawara, H. Satoh, K. Nagashima, H. Hara, Y. Nakatsu, and T. Aizawa Arterial remodeling patterns before intervention predict diffuse in-stent restenosis: An intravascular ultrasound study J. Am. Coll. Cardiol., November 19, 2003; 42(10): 1731 - 1738. [Abstract] [Full Text] [PDF] |
||||
![]() |
N. J. Weissman Vascular remodeling: do we really need yet another study? J. Am. Coll. Cardiol., September 3, 2003; 42(5): 811 - 813. [Full Text] [PDF] |
||||
![]() |
A L Gaster, U Slothuus Skjoldborg, J Larsen, L Korsholm, C von Birgelen, S Jensen, P Thayssen, K E Pedersen, and T H Haghfelt Continued improvement of clinical outcome and cost effectiveness following intravascular ultrasound guided PCI: insights from a prospective, randomised study Heart, September 1, 2003; 89(9): 1043 - 1049. [Abstract] [Full Text] [PDF] |
||||
![]() |
E. Cheneau, L. Leborgne, G. S. Mintz, J.-i. Kotani, A. D. Pichard, L. F. Satler, D. Canos, M. Castagna, N. J. Weissman, and R. Waksman Predictors of Subacute Stent Thrombosis: Results of a Systematic Intravascular Ultrasound Study Circulation, July 8, 2003; 108(1): 43 - 47. [Abstract] [Full Text] [PDF] |
||||
![]() |
B E Bouma, G J Tearney, H Yabushita, M Shishkov, C R Kauffman, D DeJoseph Gauthier, B D MacNeill, S L Houser, H T Aretz, E F Halpern, et al. Evaluation of intracoronary stenting by intravascular optical coherence tomography Heart, March 1, 2003; 89(3): 317 - 320. [Abstract] [Full Text] [PDF] |
||||
![]() |
P. V. Oemrawsingh, G. S. Mintz, M. J. Schalij, A. H. Zwinderman, J. W. Jukema, and E. E.v.d. Wall Intravascular Ultrasound Guidance Improves Angiographic and Clinical Outcome of Stent Implantation for Long Coronary Artery Stenoses: Final Results of a Randomized Comparison With Angiographic Guidance (TULIP Study) Circulation, January 7, 2003; 107(1): 62 - 67. [Abstract] [Full Text] [PDF] |
||||
![]() |
V. Spanos, G. Stankovic, J. Tobis, and A. Colombo The challenge of in-stent restenosis: insights from intravascular ultrasound Eur. Heart J., January 2, 2003; 24(2): 138 - 150. [Full Text] [PDF] |
||||
![]() |
N. J. Goswami, J. M. Moody Jr, and S. R. Bailey Percutaneous Mechanical Reperfusion During Acute Myocardial Infarction J Intensive Care Med, July 1, 2002; 17(4): 162 - 173. [Abstract] [PDF] |
||||
![]() |
N. H.J. Pijls, V. Klauss, U. Siebert, E. Powers, K. Takazawa, W. F. Fearon, J. Escaned, Y. Tsurumi, T. Akasaka, H. Samady, et al. Coronary Pressure Measurement After Stenting Predicts Adverse Events at Follow-Up: A Multicenter Registry Circulation, June 25, 2002; 105(25): 2950 - 2954. [Abstract] [Full Text] [PDF] |
||||
![]() |
G. Dangas and F. Kuepper Restenosis: Repeat Narrowing of a Coronary Artery: Prevention and Treatment Circulation, June 4, 2002; 105(22): 2586 - 2587. [Full Text] [PDF] |
||||
![]() |
M. Voskuil, R. A. M. van Liebergen, M. Albertal, E. Boersma, J. G. P. Tijssen, P. W. Serruys, J. J. Piek, and the DEBATE II Investigators Coronary hemodynamics of stent implantation after suboptimal and optimal balloon angioplasty J. Am. Coll. Cardiol., May 1, 2002; 39(9): 1513 - 1517. [Abstract] [Full Text] [PDF] |
||||
![]() |
C. Briguori, J. Tobis, T. Nishida, M. Vaghetti, R. Albiero, C. Di Mario, and A. Colombo Discrepancy between angiography and intravascular ultrasound when analysing small coronary arteries Eur. Heart J., February 1, 2002; 23(3): 247 - 254. [Abstract] [Full Text] [PDF] |
||||
![]() |
M. J. Kern The meaning of suboptimal coronary flow reserve after coronary balloon angioplasty Eur. Heart J., January 2, 2002; 23(2): 99 - 100. [Full Text] [PDF] |
||||
![]() |
N.G. Uren, S.P. Schwarzacher, J.A. Metz, D.P. Lee, Y. Honda, A.C. Yeung, P.J. Fitzgerald, and P.G. Yock Predictors and outcomes of stent thrombosis. An intravascular ultrasound registry Eur. Heart J., January 2, 2002; 23(2): 124 - 132. [Abstract] [Full Text] [PDF] |
||||
![]() |
Y. Takano, L. A. Yeatman, J. R. Higgins, J. W. Currier, E. Ascencio, K. A. Kopelson, and J. M. Tobis Optimizing stent expansion with new stent delivery systems J. Am. Coll. Cardiol., November 15, 2001; 38(6): 1622 - 1627. [Abstract] [Full Text] [PDF] |
||||
![]() |
R. Hoffmann, P. Haager, G.S. Mintz, G. Kerckhoff, R. Schwarz, A. Franke, J. Vom Dahl, and P. Hanrath The impact of high pressure vs low pressure stent implantation on intimal hyperplasia and follow-up lumen dimensions; results of a randomized trial Eur. Heart J., November 1, 2001; 22(21): 2015 - 2024. [Abstract] [PDF] |
||||
![]() |
W. F. Fearon, J. Luna, H. Samady, E. R. Powers, T. Feldman, N. Dib, E. M. Tuzcu, M. W. Cleman, T. M. Chou, D. J. Cohen, et al. Fractional Flow Reserve Compared With Intravascular Ultrasound Guidance for Optimizing Stent Deployment Circulation, October 16, 2001; 104(16): 1917 - 1922. [Abstract] [Full Text] [PDF] |
||||
![]() |
M. J. Kern and B. Meier Evaluation of the Culprit Plaque and the Physiological Significance of Coronary Atherosclerotic Narrowings Circulation, June 26, 2001; 103(25): 3142 - 3149. [Full Text] [PDF] |
||||
![]() |
H. Schuhlen, A. Kastrati, J.u. Pache, J. Dirschinger, and A. Schomig Incidence of thrombotic occlusion and major adverse cardiac events between two and four weeks after coronary stent placement: analysis of 5,678 patients with a four-week ticlopidine regimen J. Am. Coll. Cardiol., June 15, 2001; 37(8): 2066 - 2073. [Abstract] [Full Text] [PDF] |
||||
![]() |
S. C. Smith Jr, J. T. Dove, A. K. Jacobs, J. Ward Kennedy, D. Kereiakes, M. J. Kern, R. E. Kuntz, J. J. Popma, H. V. Schaff, D. O. Williams, et al. ACC/AHA guidelines for percutaneous coronary intervention (revision of the 1993 PTCA guidelines): A report of the American College of Cardiology/ American Heart Association Task Force on practice guidelines (Committee to revise the 1993 guidelines for percutaneous transluminal coronary angioplasty) endorsed by the Society for Cardiac Angiography and Interventions J. Am. Coll. Cardiol., June 15, 2001; 37(8): 2239 - 2239. [Full Text] [PDF] |
||||
![]() |
A L MCLEOD, D B NORTHRIDGE, and N G UREN Ultrasound guided stenting Heart, June 1, 2001; 85(6): 605 - 606. [Full Text] |
||||
![]() |
F. Schiele Intravascular Ultrasound Guidance for Stent Implantation Circulation, May 29, 2001; 103 (21): e110 - e110. [Full Text] [PDF] |
||||
![]() |
H. Okura, Y. Morino, A. Oshima, M. Hayase, M. R. Ward, J. J. Popma, R. E. Kuntz, H. N. Bonneau, P. G. Yock, and P. J. Fitzgerald Preintervention arterial remodeling affects clinical outcome following stenting: an intravascular ultrasound study J. Am. Coll. Cardiol., March 15, 2001; 37(4): 1031 - 1035. [Abstract] [Full Text] [PDF] |
||||
![]() |
S. E. Nissen and P. Yock Intravascular Ultrasound : Novel Pathophysiological Insights and Current Clinical Applications Circulation, January 30, 2001; 103(4): 604 - 616. [Abstract] [Full Text] [PDF] |
||||
![]() |
IVUS Improves Stent Expansion Journal Watch Cardiology, October 13, 2000; 2000(1013): 3 - 3. [Full Text] |
||||
|