Donate Help Contact The AHA Sign In Home
American Heart Association
Circulation
Search: search_blue_button Advanced Search
Circulation. 2000;102:399-404

This Article
Right arrow Full Text
Right arrow Full Text (PDF)
Right arrow Alert me when this article is cited
Right arrow Alert me if a correction is posted
Right arrow Citation Map
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Download to citation manager
Right arrow Request Permissions
Citing Articles
Right arrow Citing Articles via HighWire
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Tamai, H.
Right arrow Articles by Uehata, H.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Tamai, H.
Right arrow Articles by Uehata, H.
Related Collections
Right arrow Catheter-based coronary interventions: stents

(Circulation. 2000;102:399.)
© 2000 American Heart Association, Inc.


Clinical Investigation and Reports

Initial and 6-Month Results of Biodegradable Poly-l-Lactic Acid Coronary Stents in Humans

Hideo Tamai, MD; Keiji Igaki; Eisho Kyo, MD; Kunihiko Kosuga, MD; Akiyoshi Kawashima, MD; Shigeo Matsui, MD; Hidenori Komori, MD; Takafumi Tsuji, MD; Seiichiro Motohara, MD; Hiromu Uehata, MD

From the Department of Cardiology, Shiga Medical Center for Adults, Shiga, Japan (H.T., E.K., K.K, A.K., S.M., H.K., T.T., S.M., H.U.), and Igaki Medical Planning Co, Ltd, Kyoto, Japan (K.I.).

Correspondence to Hideo Tamai, MD, Department of Cardiology, Shiga Medical Center for Adults, 5-4-30, Moriyama, Moriyama, Shiga, Japan.

Background—Although metallic stents are effective in preventing acute occlusion and reducing late restenosis after coronary angioplasty, many concerns still remain. Compared with metallic stents, poly-l-lactic acid (PLLA) stents are biodegradable and can deliver drugs locally. The aim of this study was to evaluate the feasibility, safety, and efficacy of the PLLA stent.

Methods and Results—Fifteen patients electively underwent PLLA Igaki-Tamai stent implantation for coronary artery stenoses. The Igaki-Tamai stent is made of a PLLA monopolymer, has a thickness of 0.17 mm, and has a zigzag helical coil pattern. A balloon-expandable covered sheath system was used, and the stent expanded by itself to its original size with an adequate temperature. A total of 25 stents were successfully implanted in 19 lesions in 15 patients, and angiographic success was achieved in all procedures. No stent thrombosis and no major cardiac event occurred within 30 days. Coronary angiography and intravascular ultrasound were serially performed 1 day, 3 months, and 6 months after the procedure. Angiographically, both the restenosis rate and target lesion revascularization rate per lesion were 10.5%; the rates per patient were 6.7% at 6 months. Intravascular ultrasound findings revealed no significant stent recoil at 1 day, and they revealed stent expansion at follow-up. No major cardiac event, except for repeat angioplasty, developed within 6 months.

Conclusions—Our preliminary experience suggests that coronary PLLA biodegradable stents are feasible, safe, and effective in humans. Long-term follow-up with more patients will be required to validate the long-term efficacy of PLLA stents.


Key Words: angioplasty • stents • coronary disease




This article has been cited by other articles:


Home page
Toxicol PatholHome page
M. N. Helmus, D. F. Gibbons, and D. Cebon
Biocompatibility: Meeting a Key Functional Requirement of Next-Generation Medical Devices
Toxicol Pathol, January 1, 2008; 36(1): 70 - 80.
[Abstract] [Full Text] [PDF]


Home page
CirculationHome page
J. Daemen and P. W. Serruys
Drug-Eluting Stent Update 2007: Part I: A Survey of Current and Future Generation Drug-Eluting Stents: Meaningful Advances or More of the Same?
Circulation, July 17, 2007; 116(3): 316 - 328.
[Full Text] [PDF]


Home page
PERSPECT VASC SURG ENDOVASC THERHome page
P. J. Geraghty
Bioabsorbable Stenting for Peripheral Arterial Occlusive Disease
Perspectives in Vascular Surgery and Endovascular Therapy, December 1, 2006; 18(4): 295 - 298.
[Abstract] [PDF]


Home page
VASC ENDOVASCULAR SURGHome page
D. R. Whittaker and M. F. Fillinger
The Engineering of Endovascular Stent Technology: A Review
Vascular and Endovascular Surgery, March 1, 2006; 40(2): 85 - 94.
[Abstract] [PDF]


Home page
NEJMHome page
P. W. Serruys, M. J.B. Kutryk, and A. T.L. Ong
Coronary-Artery Stents
N. Engl. J. Med., February 2, 2006; 354(5): 483 - 495.
[Full Text] [PDF]


Home page
CirculationHome page
M. A. Costa and D. I. Simon
Molecular Basis of Restenosis and Drug-Eluting Stents
Circulation, May 3, 2005; 111(17): 2257 - 2273.
[Full Text] [PDF]


Home page
CirculationHome page
J. E. Sousa, M. A. Costa, E. M. Tuzcu, J. S. Yadav, and S. Ellis
New Frontiers in Interventional Cardiology
Circulation, February 8, 2005; 111(5): 671 - 681.
[Full Text] [PDF]


Home page
RadiologyHome page
B. Lu, N. Zhuang, S.-S. Mao, J. Child, S. Carson, and M. J. Budoff
Baseline Heart Rate-adjusted Electrocardiographic Triggering for Coronary Artery Electron-Beam CT Angiography
Radiology, November 1, 2004; 233(2): 590 - 595.
[Abstract] [Full Text] [PDF]


Home page
Eur Heart JHome page
F. Vogt, A. Stein, G. Rettemeier, N. Krott, R. Hoffmann, J. v. Dahl, A.-K. Bosserhoff, W. Michaeli, P. Hanrath, C. Weber, et al.
Long-term assessment of a novel biodegradable paclitaxel-eluting coronary polylactide stent
Eur. Heart J., August 1, 2004; 25(15): 1330 - 1340.
[Abstract] [Full Text] [PDF]


Home page
HeartHome page
B Heublein, R Rohde, V Kaese, M Niemeyer, W Hartung, and A Haverich
Biocorrosion of magnesium alloys: a new principle in cardiovascular implant technology?
Heart, June 1, 2003; 89(6): 651 - 656.
[Abstract] [Full Text] [PDF]


Home page
CirculationHome page
T. Ozawa, D. A. G. Mickle, R. D. Weisel, N. Koyama, S. Ozawa, and R.-K. Li
Optimal Biomaterial for Creation of Autologous Cardiac Grafts
Circulation, September 24, 2002; 106(12_suppl_1): I-176 - I-182.
[Abstract] [Full Text] [PDF]


Home page
HeartHome page
M Peuster, P Wohlsein, M Brugmann, M Ehlerding, K Seidler, C Fink, H Brauer, A Fischer, and G Hausdorf
A novel approach to temporary stenting: degradable cardiovascular stents produced from corrodible metal---results 6-18 months after implantation into New Zealand white rabbits
Heart, November 1, 2001; 86(5): 563 - 569.
[Abstract] [Full Text] [PDF]


Home page
Br Med BullHome page
E Regar, G Sianos, and P W Serruys
Stent development and local drug delivery
Br. Med. Bull., October 1, 2001; 59(1): 227 - 248.
[Abstract] [Full Text] [PDF]


Home page
NEJMHome page
T. H. Baron
Expandable Metal Stents for the Treatment of Cancerous Obstruction of the Gastrointestinal Tract
N. Engl. J. Med., May 31, 2001; 344(22): 1681 - 1687.
[Full Text] [PDF]


Home page
CirculationHome page
V. Sriram and C. Patterson
Cell Cycle in Vasculoproliferative Diseases : Potential Interventions and Routes of Delivery
Circulation, May 15, 2001; 103(19): 2414 - 2419.
[Abstract] [Full Text] [PDF]


Home page
Eur Heart JHome page
R. Seabra-Gomes
Radioactive stents to reduce restenosis: time for an epitaph?
Eur. Heart J., April 2, 2001; 22(8): 621 - 623.
[PDF]


Home page
Journal Watch CardiologyHome page
Early Results with Biodegradable Stents
Journal Watch Cardiology, September 29, 2000; 2000(929): 1 - 1.
[Full Text]


Home page
CirculationHome page
A. Colombo and E. Karvouni
Biodegradable Stents : "Fulfilling the Mission and Stepping Away"
Circulation, July 25, 2000; 102(4): 371 - 373.
[Full Text] [PDF]