(Circulation. 2000;102:2497.)
© 2000 American Heart Association, Inc.
Clinical Investigation and Reports |
From the Department of Clinical Research, Herz-Zentrum, Bad Krozingen, Germany.
Correspondence to Axel W. Frey, MD, PhD, Head of Department, Clinical Research, Herz-Zentrum, Sudring 15, Bad Krozingen, Germany 79188. E-mail axelfrey{at}t-online.de
BackgroundIntracoronary ultrasound (ICUS) has provided insights into vascular pathology and interventional therapy. The Strategy for ICUS-Guided PTCA and Stenting (SIPS) trial tested the hypothesis that routine ICUS guidance of coronary interventions improves outcome.
Methods and ResultsA single-center consecutive-patient randomized design (with 6-month angiographic and 2-year clinical follow-up) was used. Consecutive patients (no chronic total occlusions or emergency procedures) were randomized to ICUS-guided provisional stenting or standard angiographic guidance. Quantitative angiographic minimal lumen diameter (MLD), angiographic restenosis, clinically driven target lesion revascularization, and major adverse cardiac events (MACEs) were evaluated. A total of 291 procedures (356 lesions) were included. Procedure success was higher in the ICUS-guided group than the group randomized to standard guidance (94.7% versus 87.4%, respectively; P=0.033), whereas time (65.2±31.0 versus 60.5±34.0 minutes, P=0.18) and contrast use (209.3±94.1 versus 197.5±89.5 mL, P=0.23) were not significantly different. Stenting rates were similar (49.7% versus 49.5%, P=0.89). Acute gain was greater in the ICUS-guided group than in the standard guidance group (1.85±0.72 versus 1.67±0.76 mm, respectively; P=0.02). Angiographic 6-month analysis revealed no difference in MLD (1.71±0.94 versus 1.57±0.90, P=0.19) or binary restenosis rate (>50% diameter stenosis) (29% versus 35%, P=0.42). Clinical follow-up (602±307 days) showed a significant decrease in clinically driven target lesion revascularization in the ICUS group compared with the standard guidance group (17% versus 29%, respectively; P=0.02).
ConclusionsAlthough angiographic MLD did not differ significantly after 6 months, ICUS-guided provisional stenting improved 2-year clinical results after intervention.
Key Words: coronary disease imaging angioplasty restenosis stents
This article has been cited by other articles:
![]() |
E. Romagnoli, G. M. Sangiorgi, J. Cosgrave, E. Guillet, and A. Colombo Drug-Eluting Stenting: The Case for Post-Dilation J. Am. Coll. Cardiol. Intv., February 1, 2008; 1(1): 22 - 31. [Abstract] [Full Text] [PDF] |
||||
![]() |
H.-P. Bestehorn, F.-J. Neumann, H. J. Buttner, P. Betz, P. Sturzenhofecker, E. von Hodenberg, A. Verdun, L. Levai, J. P. Monassier, and H. Roskamm Evaluation of the effect of oral verapamil on clinical outcome and angiographic restenosis after percutaneous coronary intervention: The randomized, double-blind, placebo-controlled, multicenter verapamil slow-release for prevention of cardiovascular events after angioplasty (VESPA) trial J. Am. Coll. Cardiol., June 16, 2004; 43(12): 2160 - 2165. [Abstract] [Full Text] [PDF] |
||||
![]() |
J. L. Orford, A. Lerman, and D. R. Holmes Routine intravascular ultrasound guidance of percutaneous coronary intervention: A critical reappraisal J. Am. Coll. Cardiol., April 21, 2004; 43(8): 1335 - 1342. [Abstract] [Full Text] [PDF] |
||||
![]() |
D. M. Thys Clinical Competence in Echocardiography Anesth. Analg., August 1, 2003; 97(2): 313 - 322. [Full Text] [PDF] |
||||
![]() |
M. A. Quinones, P. S. Douglas, E. Foster, J. Gorcsan III, J. F. Lewis, A. S. Pearlman, J. Rychik, E. E. Salcedo, J. B. Seward, J. G. Stevenson, et al. American College of Cardiology/American Heart Association Clinical Competence Statement on Echocardiography: A Report of the American College of Cardiology/American Heart Association/American College of Physicians--American Society of Internal Medicine Task Force on Clinical Competence Circulation, February 25, 2003; 107(7): 1068 - 1089. [Full Text] [PDF] |
||||
![]() |
M. A. Quinones, P. S. Douglas, E. Foster, J. Gorcsan III, J. F. Lewis, A. S. Pearlman, J. Rychik, E. E. Salcedo, J. B. Seward, J. G. Stevenson, et al. ACC/AHA clinical competence statement on echocardiography : A Report of the American College of Cardiology/American Heart Association/American College of Physicians-American Society of Internal Medicine Task Force on Clinical Competence Developed in Collaboration with the American Society of Echocardiography, the Society of Cardiovascular Anesthesiologists, and the Society of Pediatric Echocardiography J. Am. Coll. Cardiol., February 19, 2003; 41(4): 687 - 708. [Full Text] [PDF] |
||||
![]() |
F. Schiele, N. Meneveau, M. Gilard, J. Boschat, P. Commeau, L. P. Ming, P. Sewoke, M.-F. Seronde, M. Mercier, S. Gupta, et al. Intravascular Ultrasound-Guided Balloon Angioplasty Compared With Stent: Immediate and 6-Month Results of the Multicenter, Randomized Balloon Equivalent to Stent Study (BEST) Circulation, February 4, 2003; 107(4): 545 - 551. [Abstract] [Full Text] [PDF] |
||||
![]() |
P. V. Oemrawsingh, G. S. Mintz, M. J. Schalij, A. H. Zwinderman, J. W. Jukema, and E. E.v.d. Wall Intravascular Ultrasound Guidance Improves Angiographic and Clinical Outcome of Stent Implantation for Long Coronary Artery Stenoses: Final Results of a Randomized Comparison With Angiographic Guidance (TULIP Study) Circulation, January 7, 2003; 107(1): 62 - 67. [Abstract] [Full Text] [PDF] |
||||
![]() |
C. Briguori, J. Tobis, T. Nishida, M. Vaghetti, R. Albiero, C. Di Mario, and A. Colombo Discrepancy between angiography and intravascular ultrasound when analysing small coronary arteries Eur. Heart J., February 1, 2002; 23(3): 247 - 254. [Abstract] [Full Text] [PDF] |
||||
![]() |
M. J. Kern The meaning of suboptimal coronary flow reserve after coronary balloon angioplasty Eur. Heart J., January 2, 2002; 23(2): 99 - 100. [Full Text] [PDF] |
||||
![]() |
A. Colombo, J. De Gregorio, I. Moussa, Y. Kobayashi, E. Karvouni, C. Di Mario, R. Albiero, L. Finci, and J. Moses Intravascular ultrasound-guided percutaneous transluminal coronary angioplasty with provisional spot stenting for treatment of long coronary lesions J. Am. Coll. Cardiol., November 1, 2001; 38(5): 1427 - 1433. [Abstract] [Full Text] [PDF] |
||||
![]() |
H. Mudra, C. di Mario, P. de Jaegere, H. R. Figulla, C. Macaya, R. Zahn, B. Wennerblom, W. Rutsch, V. Voudris, E. Regar, et al. Randomized Comparison of Coronary Stent Implantation Under Ultrasound or Angiographic Guidance to Reduce Stent Restenosis (OPTICUS Study) Circulation, September 18, 2001; 104(12): 1343 - 1349. [Abstract] [Full Text] [PDF] |
||||
|
Circulation Home | Subscriptions | Archives | Feedback | Authors | Help | AHA Journals Home | Search Copyright © 2000 American Heart Association, Inc. All rights reserved. Unauthorized use prohibited. |