Donate Help Contact The AHA Sign In Home
American Heart Association
Circulation
Search: search_blue_button Advanced Search
Circulation. 1999;100:2344-2352

This Article
Right arrow Full Text
Right arrow Full Text (PDF)
Right arrow Alert me when this article is cited
Right arrow Alert me if a correction is posted
Right arrow Citation Map
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Download to citation manager
Right arrow Request Permissions
Citing Articles
Right arrow Citing Articles via HighWire
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Kay, G. N.
Right arrow Articles by Investigators for the Accufix Multicenter Clinical Study,
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Kay, G. N.
Right arrow Articles by Investigators for the Accufix Multicenter Clinical Study,

(Circulation. 1999;100:2344.)
© 1999 American Heart Association, Inc.


Clinical Investigation and Reports

Risks of Spontaneous Injury and Extraction of an Active Fixation Pacemaker Lead

Report of the Accufix Multicenter Clinical Study and Worldwide Registry

G. Neal Kay, MD; Jeffrey A. Brinker, MD; David T. Kawanishi, MD; Charles J. Love, MD; Margaret A. Lloyd, MD; Russell C. Reeves, MD; Guy Pioger, MD; JoAnn Fee, RN, BSN; Mary K. Overland, PhD; Lisa Garnsey Ensign, MS; Gary L. Grunkemeier, PhD; for the Accufix Multicenter Clinical Study Investigators

From the University of Alabama, Birmingham (G.N.K., R.C.R.), Johns Hopkins University (J.A.B.), Baltimore, Md; University of Southern California (D.T.K.), Los Angeles; Ohio State University (C.J.L.), Columbus; Mayo Clinic Foundation (M.A.L.), Rochester, Minn; Clinique Alleray-Labrousse (G.P.), Paris, France; Accufix Research Institute (J.F., M.K.O., L.G.E.), Denver, Colo; and Medical Data Research Center (G.L.G.), Providence Health System, Portland, Ore.

Correspondence to G. Neal Kay, MD, 321J Tinsley Harrison Tower, University of Alabama at Birmingham, Birmingham, AL 35294.

Background—The Telectronics Accufix pacing leads were recalled in November 1994 after 2 deaths and 2 nonfatal injuries were reported. This multicenter clinical study (MCS) of patients with Accufix leads was designed to determine the rate of spontaneous injury related to the J retention wire and results of lead extraction.

Methods and Results—The MCS included 2589 patients with Accufix atrial pacing leads that were implanted at or who were followed up at 12 medical centers. Patients underwent cinefluoroscopic imaging of their lead every 6 months. The risk of J retention wire fracture was {approx}5.6%/y at 5 years and 4.7%/y at 10 years after implantation. The annual risk of protrusion was 1.5%. A total of 40 spontaneous injuries were reported to a worldwide registry (WWR) that included data from 34 672 patients (34 892 Accufix leads), including pericardial tamponade (n=19), pericardial effusion (n=5), atrial perforation (n=3), J retention wire embolization (n=4), and death (n=6). The risk of injury was 0.02%/y (95% CI, 0.0025 to 0.072) in the MCS and 0.048%/y (95% CI, 0.035 to 0.067) in the WWR. A total of 5299 leads (13%) have been extracted worldwide. After recall in the WWR, fatal extraction complications occurred in 0.4% of intravascular procedures (16 of 4023), with life-threatening complications in 0.5% (n=21). Extraction complications increased with implant duration, female sex, and J retention wire protrusion.

Conclusions—Accufix pacing leads pose a low, ongoing risk of injury. Extraction is associated with substantially higher risks, and a conservative management approach is indicated for most patients.


Key Words: pacemakers • pacing • complications




This article has been cited by other articles:


Home page
JAMAHome page
M. S. Amin, D. B. Matchar, M. A. Wood, and K. A. Ellenbogen
Management of recalled pacemakers and implantable cardioverter-defibrillators: a decision analysis model.
JAMA, July 26, 2006; 296(4): 412 - 420.
[Abstract] [Full Text] [PDF]


Home page
Journal Watch CardiologyHome page
Conservative Approach for Extraction of Accufix Leads
Journal Watch Cardiology, January 21, 2000; 2000(121): 10 - 10.
[Full Text]